LINK LABS LL-RLP-20 Manual Download Page 16

 

 

LL-RLP-20 Datasheet 

www.link-labs.com

    

Information contained in this document is subject to change without notification

 

 

14 

IMPORTANT NOTICE 

DISCLAIMER 

Link Labs, LLC (hereafter referred to as “Link Labs”) reserves the right to make corrections, enhancements, 
improvements and other changes to its products and services. Buyers should obtain the latest relevant information 
before placing orders and should verify that such information is current and complete. All products (also referred to 
herein as “components”) are sold subject to Link Labs’ terms and conditions of sale supplied at the time of order 
acknowledgment. 
 
Link Labs warrants performance of its components to the specifications applicable at the time of sale, in accordance 
with the warranty in Link Labs’ terms and conditions of sale. Testing and other quality control techniques are used to 
the extent Link Labs deems necessary to support this warranty. Except where mandated by applicable law, testing of 
all parameters of each component is not necessarily performed. 
 
Link Labs assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible 
for 

their products and applications using Link Labs components. To minimize the risks associated with Buyers’ 

products and applications, Buyers should provide adequate design and operating safeguards. 
 
Link Labs does not warrant or represent that any license, either express or implied, is granted under any patent right, 
copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in 
which Link Labs components or services are used. Information published by Link Labs regarding third-party products 
or services does not constitute a license to use such products or services or a warranty or endorsement thereof. Use 
of such information may require a license from a third party under the patents or other intellectual property of the third 
party, or a license from Link Labs under the patents or other intellectual property of Link Labs. 
 
Reproduction of significant portions of Link Labs information in 

Buyers’ data books or data sheets is permissible only 

if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and 
notices. Link Labs is not responsible or liable for such altered documentation. Information of third parties may be 
subject to additional restrictions. 
 
Resale of Link Labs components or services with statements different from or beyond the parameters stated by Link 
Labs for that component or service voids all express and any implied warranties for the associated Link Labs 
component or service and is an unfair and deceptive business practice. Link Labs is not responsible or liable for any 
such statements. 
 
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-
related requirements concerning its products, and any use of Link Labs components in its applications, 
notwithstanding any applications-related information or support that may be provided by Link Labs. Buyer represents 
and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous 
consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause 
harm and take appropriate remedial actions. Buyer will fully indemnify Link Labs and its representatives against any 
damages arising out of the use of any Link Labs components in safety-critical applications. 
 
In some cases, Link Labs components may be promoted specifically to facilitate safety-related applications. With 
such components, Link Labs’ goal is to help enable customers to design and create their own end-product solutions 
that meet applicable functional safety standards and requirements. Nonetheless, such components are subject to 
these terms. 
 
No Link Labs components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless 
authorized officers of the parties have executed a special agreement specifically governing such use. 
 
Only those Link Labs components which Link Labs has specifically designated as military grade are designed and 
intended for use in military/aerospace applications or environments. Buyer acknowledges and agrees that any military 
or aerospace use of Link Labs components which have 

not 

been so designated is solely at the Buyer's risk, and that 

Buyer is solely responsible for compliance with all legal and regulatory requirements in connection with such use. 

 

Summary of Contents for LL-RLP-20

Page 1: ...Low Power License free RF Transceiver Module LL RLP 20 Datasheet May 2015 www link labs com ...

Page 2: ...7 TRACE ANTENNA DESIGN 7 REGULATORY COMPLIANCE INFORMATION 9 U S CANADA OEM LABELING REQUIREMENTS FOR END PRODUCT 9 U S CANADA OEM END PRODUCT USER MANUAL STATEMENTS 9 FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT 10 INDUSTRY CANADA STATEMENTS 7 ETSI COMPLIANCE INFORMATION 8 IMPORTANT NOTICE 14 DISCLAIMER 14 ...

Page 3: ... without notification 1 CHANGE LOG Date Revision Changed By Description 05 07 2015 0 1 J Wathen Added how to description for separating trace antenna from pcb 08 04 2015 0 2 R Zanski Added I O voltage limits pin terminations module regulator specifications and clarification of module keep out area ...

Page 4: ...μA unregulated SPECIFICATIONS Frequency bands 915 MHz ISM 902 MHz 928 MHz 868 MHz ETSI On air data rate 183 bps to 37 5 kbps Output power Programmable 18 5 to 4 dBm in 0 6 dB steps Supply Voltage 3 5 V to 5 5 V VCC 3 3 V1 2 7 3 6 V2 Onboard Regulator VIN 3 5 5 5 V Vout 3 3 v Max current 250 mA Iq 7 9 uA PSRR 85 dB at 10 Hz 70 dB at 1kHz 40 dB at 100kHz I O Voltage 3 3 V typ 1 VIH min VCC 0 8 max V...

Page 5: ...ge Devices specified in the ERC Recommendation 70 03 Note Regulations can vary by country and the manufacturer of the end device must ensure they are complying with local laws and regulations Band Edge Frequencies Tx Power Duty Cycle Bandwidth g1 868 0 MHz 868 6 MHz 14 dBm 1 or LBT AFA 600 kHz g2 868 7 MHz 869 2 MHz 14 dBm 0 1 or LBT AFA 500 kHz g3 869 4 MHz 869 65 MHz 27 dBm 10 or LBT AFA 250 kHz...

Page 6: ...LL RLP 20 Datasheet www link labs com Information contained in this document is subject to change without notification 4 MODULE FOOTPRINT Figure 1 Module Footprint ...

Page 7: ...6 8 IO SPI1 master in slave out 13 SMOSI1 SSDA16 8 IO SPI1 master out slave in 14 Reserved NC 15 SCK16 8 IO SPI1 serial clock 16 Reserved NC 17 BOOT I NC Boot normally GND Bootloader 18 nSS16 8 IO SPI1 slave select 19 FINEC8 IO FINE interface 20 Reserved NC 21 Reserved NC 22 Analog Input6 8 I 0 VCC 23 HOST_RXIN4 I UART interface module Rx 24 HOST_TXOUT4 O UART interface module Tx 25 GND Ground Not...

Page 8: ...LL RLP 20 Datasheet www link labs com Information contained in this document is subject to change without notification 6 7 Pin has an internal pull up 8 NC if not used ...

Page 9: ...The module must be used with one of the approved antennas wave center fed dipole antennas tuned for 915 MHz with a maximum gain of 1 9 dBi or less such as ANT 916 CW HWR SMA Integrated trace antenna TRACE ANTENNA REFERENCE DESIGN The red area in Fig 2 represents the copper ground pour an end user must build into his her carrier board for the trace antenna to perform optimally This ground pour cont...

Page 10: ... module s PCB is pre scored along the line between the module and the trace antenna for this purpose To separate the trace antenna use a sharp blade to cut along the score line on both the top and bottom sides of the board Then gently flex the antenna until it separates If the antenna does not separate readily continue to cut the score line until it can be removed without applying excessive force ...

Page 11: ... is labeled with its own FCC ID and IC Certification Number The FCC ID and IC certification numbers are not visible when the module is installed inside another device as such the end device into which the module is installed must display a label referring to the enclosed module The final end product must be labeled in a visible area with the following Contains Transmitter Module FCC ID 2ACT6LLRLP2...

Page 12: ...conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Conformité aux normes FCC Cet équipement a été testé et trouvé c...

Page 13: ...in this document is subject to change without notification 11 Les changements ou modififications à cet appareil sans expressément approuvée par la partie responsable de conformité pourraient annuler l autorité de l utilisateur de faire fonctionner cet équipement ...

Page 14: ...trictly prohibited for use with this device The required antenna impedance is 50 ohms Cet appareil est conforme avec Industrie Canada exempt de licence Rss standard s Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne peut causer d interférences et 2 cet appareil doit accepter toute interférence y compris des interférences qui peuvent provoquer un fonctionnement indésira...

Page 15: ...mbedded into other products referred as final products According to the R TTE directive the declaration of compliance with essential requirements of the R TTE directive is within the responsibility of the manufacturer of the final product A declaration of conformity for the radio module is available from Link Labs LLC on request The applicable regulation requirements are subject to change Link Lab...

Page 16: ...n and is accompanied by all associated warranties conditions limitations and notices Link Labs is not responsible or liable for such altered documentation Information of third parties may be subject to additional restrictions Resale of Link Labs components or services with statements different from or beyond the parameters stated by Link Labs for that component or service voids all express and any...