The PERS-2400A Console is a supervised wireless emergency reporting product designed 
for medical alert applications. The table-top or wall-mount Console provides “pushbutton” 
emergency assistance to anyone who desires additional security and peace of mind. For 
the  visually  impaired,  each  button  on  the  Console  is  molded  with  braille  characters  to 
identify the button’s function.

 

The  Console  receives  signals  from  up  to  16  Linear  wireless  transmitters.  Activating  a 
transmitter causes the Console’s digital communicator to send the appropriate alarm report 
to  the  central  monitoring  station  via  the  standard  telephone  network.  In  addition  to  the 
central station report, audible and visual indications occur and the alarm relay energizes 
during an emergency activation.
The emergency alarm can be triggered by the large EMERGENCY button on the face of the 
Console or with a wireless transmitter. The fi re alarm can be triggered by wireless smoke 
alarms.
The optional 

activity timer

 can be set for 8, 12 or 24 hour operation. The emergency alarm 

will trigger automatically if the time set elapses before an activity transmitter is triggered or 
the Console’s HOME button is pressed.
If  the  optional  Model  VB-4  voice  board  is  installed,  the  Console  will  “talk”  to  the  user. 
The  digitized  voice,  will  sound “emergency”, “fi re”, “timer  done  soon”,  and  other  system 
operation,  setup,  and  supervisory  prompts  from  a  38  word  vocabulary.  In  addition, 
the  voice  board  supports  2-way  automatic,  2-way  manual,  and  1-way  listen-only  audio 
communications  with  central  station  monitoring  personnel  using  the  Console’s  built-in 
high-sensivity microphone and speaker.
The  Console  can  be  programmed  to  act  as  a  remote  controlled  “speakerphone”.  With 
the  speakerphone  mode  enabled  (Model  VB-4  voice  board  required)  the  Console  will 
monitor the telephone line for an incoming call. Activating any emergency transmitter (or 
the Console’s EMERGENCY button) while the telephone is ringing will cause the Console 
to  seize  the  line  and  begin  full  duplex  voice  communications.  Activating  any  emergency 
transmitter (or EMERGENCY button) during the call will disconnect the line. The Console 
will auto-disconnect after 15, 30, or 60 minutes (programmable).
Supervised transmitters regularly send status reports to the Console and low battery reports 
when their batteries are low. When the Console receives a low battery report, the TROUBLE 
indicator fl ashes. If the Console fails to receive a status report from a transmitter for a period 
of  24 hours,  the TROUBLE  indicator  will  light.  All  supervisory  conditions  can  sound  a  local 
annunciation and be reported to the central station.
The  Console’s  digital  communicator  can  route  calls  to  three  telephone  numbers:  primary, 
secondary, and supervisory. General reporting codes and individual sensor reporting codes 
are programmable for the 4x2 format. Alternately, Ademco Contact ID may be selected for 
the communicator reporting format.
Powered by a low voltage plug-in transformer, the Console has provisions for a rechargeable 
backup battery for operation during AC power outages. A power switch allows for out-of-service 
storage of the Console without discharge of the battery. The battery is recharged and supervised 
by the Console. If the backup battery becomes low the POWER light will fl ash and the condition 
can be reported to the central station. 

The Console is programmed using Linear’s RA-2400 

remote  access  software.  Refer  to  the  software’s  built-in  help  fi le  for  programming 
details.

TRANSMITTER COMPATIBILITY

OPERATION SUMMARY

A variety of Linear’s supervised DXS and non-supervised DX format transmitters can be 
used with the Console. Transmitters can be assigned to the following three functions:

EMERGENCY

Portable, supervised and non-supervised, pendant, belt-clip, or wristband type transmitters 
(Models DXT-41, DXT-42, DXT-61A, DXS-21, DXS-23, DXS-62, DXS-63) and stationary, 
supervised  Model  DXS-31  transmitters  are  used  for  medical  alert  applications.  When 
a  medical  alert  transmitter  is  triggered,  the  Console  sounds  a  two-tone  siren  and  an 
emergency report is sent to the central station. The emergency alarm can also be triggered 
by pressing the Console’s EMERGENCY button.

FIRE

Supervised  Model  DXS-72  wireless  photoelectric  smoke  alarms  trigger  the  fi re  alarm. 
When the fi re alarm is activated, the Console sounds a repeated series of three beeps and 
a fi re report is sent to the central station.

ACTIVITY

Supervised, switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) 
can be used for ensuring human activity. The DXS-54 motion detector will monitor room 
activity. The DXS-31 and DXS-32 transmitters can be wired to a pushbutton or switch for 
manual activity monitoring. As long as a signal is received at least once every 8, 12, or 24 
hours (programmable) an alarm will 

not

 

be triggered. 15 minutes before the programmed 

time  expires,  the  HOME  indicator  will  start  blinking  and  a  low  pitched  beep  will  sound 
every ten seconds. The activity timer can be reset with a signal from one of the activity 
transmitters or by pressing the HOME button on the Console. Failure to reset the activity 
timer  within  the  programmed  time  period  will  cause  the  Console  to  sound  the  two-tone 
emergency siren and send an inactivity report to the central station. The activity timer can 
be turned on or off at the Console or through programming.

1. FRONT PANEL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
2. REMOVING BOTTOM COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
3. CONSOLE BOTTOM FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
4. OPTIONAL VB-4 VOICE BOARD INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
5. OPTIONAL RELAY OUTPUT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
6. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . .  2
7. BACKUP BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
8. INSTALL TRANSFORMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
9. APPLY POWER - SELECT DIALING METHOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
10. TRANSMITTER INSTALLATION OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
11. INSTALLING SINGLE TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
12. INSTALLING MULTIPLE TRANSMITTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
13. TESTING TRANSMITTERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
14. ERASING TRANSMITTERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
15. LOCAL PROGRAMMING WITH RA-2400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
16. TELEPHONE CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
17. SYSTEM OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
18. ACTIVITY TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
19. AUDIO BOARD OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
20. SPEAKERPHONE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
21. SUPERVISORY CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
22. WIRELESS INSTALLATION TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
LINEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6

CONSOLE

EMERGENCY

DXT-61A

DXS-21

DXS-23

DXT-41

DXT-42

FIRE

ACTIVITY

DXS-31

DXS-72

DXS-31/32

DXS-54

R

A

D

I

O

S

I

G

N

A

L

S

TO CENTRAL STATION

VIA TELEPHONE

DXS-62

DXS-63

NOTE: COMPATABILITY WITH

THE PERS-2400A HAS NOT

BEEN VERIFIED BY UL

NOTE: NOT A UL LISTED DEVICE

UP TO 16 TRANSMITTERS

CAN BE USED WITH

EACH CONSOLE

Summary of Contents for PERS-2400A

Page 1: ...S 2400A PERSONAL EMERGENCY REPORTING SYSTEM 760 438 7000 FAX 760 438 7043 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation and Operation Instructions BY...

Page 2: ...ower switch allows for out of service storage of the Console without discharge of the battery The battery is recharged and supervised by the Console If the backup battery becomes low the POWER light w...

Page 3: ...S TO ADD A TRANSMITTER PRESS TO RESET ACTIVITY TIMER PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER OFF IF ACTIVITY TIMER IS OFF PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER ON HOME BUTTON COVER ADHESIVE BA...

Page 4: ...TO POSITIVE AND BLACK LEAD TO NEGATIVE BATTERY TERMINAL FIT BATTERY INTO CONSOLE SLIDE DOWN THEN BACK OFF ON 2 3 1 PLUG TRANSFORMER INTO AN UN SWITCHED 117 VAC OUTLET SECURE TRANSFORMER WITH SCREW 2...

Page 5: ...Y TIMER ENABLED 3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 3 MINUTES 5 DXS 21 DXS 63 NOTE EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX...

Page 6: ...SOLE S LINE JACK 4 PERFORM THE STEPS DETAILED IN THE RA 2400 PERS 2400 REFERENCE GUIDE P N 217163 TO SET UP THE RA 2400 PROGRAM LINE TO LINE 5 PERFORM PROGRAMMING IN THE RA 2400 SOFTWARE THEN DISCONNE...

Page 7: ...BUTTON OR THE BUTTON ON AN EMERGENCY TRANSMITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE BUTTONS AGAIN TO REPORT THE EMERGENCY 3 TIME RUNNING OUT 2 1 ENABLING THE ACTIVITY TIMER PRESS THE HO...

Page 8: ...ONS WITH THE OPTIONAL MODEL VB 4 VOICE BOARD INSTALLED THE VOICE CAN BE DISABLED THROUGH PROGRAMMING WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE CONSOLE S TROUBLE INDICATOR WILL BLINK SLOWLY IF...

Reviews: