background image

15  Using the Garage Door Operator

Opening the Door

1

  With  the  door  in  view,  press  the  wall  station’s  UP/

DOWN ARROW button or the button assigned to the 

operator on the remote control, or enter a valid access 

code and press START/STOP on a remote keypad.

2

  When  the  operator  is  activated,  the  operator’s  lights 

will turn on and the door will begin to open.

3

  The door will open until the open limit is reached. If 

an obstacle is encountered (operator’s lights flash four 

times) while the door is opening, the door will stop.

4

  The operator’s lights will stay on for about five minutes 

after the door stops.

Closing the Door

1

  With  the  door  in  view,  press  the  wall  station’s  UP/

DOWN ARROW button or the button assigned to the 

operator on the remote control, or enter a valid access 

code and press START/STOP on a remote keypad.

2

  When  the  operator  is  activated,  the  operator’s  lights 

will turn on and the door will begin to close.

3

  The door will close until the close limit is reached. If 

an obstacle is encountered (operator’s lights flash four 

times),  or  the  safety  beam  is  interrupted  (operator’s 

lights  flash  three  times)  during  closing,  the  door  will 

stop, then re-open.

4

  The operator’s lights will stay on for about five minutes 

after the door stops.

Stopping the Door Mid-travel

1

 

The door can be stopped immediately at any time 

by pressing the wall station’s UP/DOWN ARROW 

button, the remote control’s pushbutton, or press 

the START/STOP button on a remote keypad.

2

  The next time the operator is activated, the door will 

move in the opposite direction.

Vacation Lock for Additional Security

1

  Slide  the  wall  station’s  LOCK  switch  to  the  locked 

position to prevent remote controls from opening the 

door after the door is completely closed. The remotes 

can  close  the  door,  but  not  open  it.  The  door  can 

still  be  opened  or  closed  by  using  the  wall  station’s 

UP/DOWN ARROW pushbutton.

➤ 

NOTE:

 To signal that the vacation switch is locked, 

the operator’s lights will flash five times if a remote is 
activated in an attempt to open the door.

2

  Slide the wall station’s LOCK switch to the unlocked 

position to return the operator to normal operation.

Controlling the Operator’s Lights

1

  The  operator’s  lights  can  be  lit  by  pushing  the  wall 

station’s LIGHT button. The lights will remain on until 

the LIGHT button is pressed again or the operator is 

cycled.

2

  If the operator’s lights are on, pushing the wall station’s 

LIGHT button will turn the operator’s lights off.

Disconnecting the Door from the Operator

1

  With  the  door  in  any  position  (preferably  closed), 

carefully pull the red release handle. 

USE CAUTION 

IF THE DOOR IS OPEN, THE DOOR MAY DROP.

2

  The  disconnected  door  can  be  opened  or  closed 

manually.

3

  To  re-connect  the  operator,  flip  the  release  lever  up. 

Raise  or  lower  the  door  manually  until  the  operator 

reconnects.

16  Garage Door Operator Maintenance

Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments. 

Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To 

insure safe operation of the door, perform the following tests, including any additional test steps described.

Every Month

1

  With the door closed, pull the red release handle to 

disconnect the operator from the door.

From  outside  the  garage,  slowly  open  the  door 

manually  all  the  way,  and  then  close  it  all  the  way. 

Notice if there is any binding, sticking or rubbing. The 

door should move smoothly in both directions.

3

  Raise  the  garage  door  about  halfway  up.  Carefully 

release the door and see if the door balances. It should 

stay in place. Close the door.

➤ 

NOTE:

  If  the  garage  door  is  unbalanced  or  the 

door travel isn’t smooth, have a qualified garage door 
professional adjust or repair the door.

4

  To  reconnect  the  operator,  flip  the  release  lever 

up.  Raise  the  door  manually  until  the  operator 

reconnects.

5

  Perform the Safety Beam Test (Section 11).

6

  Perform the Safety Reversal System Test as described 

in Steps 4-6 in Section 14.

After Servicing the Operator

1

  Perform the Safety Beam Test (Section 11).

2

  Perform  the  Open  and  Close  Limit  Adjustments 

(Section 13).

3

  Perform  the  entire  Door  Force  Safety  System  Test 

(Section 14).

Every 6 Months

Check the belt or chain tension.

•  For belt-drive rails, examine the length of the tension 

spring in the traveler. It should be about 1” long.

•  For  chain-drive  rails,  examine  the  spacing  between 

the turnbuckle and the rail. The turnbuckle should be 

slightly above the rail.

➤ 

NOTE:

 Too much or too little chain tension will cause 

excessive sprocket noise.

Chain Adjustment

If necessary, use the following steps to adjust the chain.

1

  Hold the turnbuckle with a flat blade screwdriver and 

loosen the two locknuts with a 7/16” end wrench.

2

  Twist the turnbuckle to adjust the chain tension. Adjust 

the chain until the turnbuckle is sightly above the rail.

3

  Hold the turnbuckle with a flat blade screwdriver and 

tighten the two locknuts with a 7/16” end wrench.

Belt Adjustment

The tension spring in the traveler keeps the belt taut. The 

factory setting for the tension spring length is .9” long. If 

the tension spring is longer than 1”, adjust the belt.

1

  Hold  the  traveler  so  the  adjustment  wheel  is  visible 

through the large slot.

2

  Use  a  flat  blade  screwdriver  to  turn  the  adjustment 

wheel to compress the tension spring until its length is 

between .9” and 1” long.

Every Year

Check the door hardware for lubrication needs. Lubricate 

door  hinges,  rollers  and  bearings  according  to  door 

manufacturer’s recommended procedures.

17  Troubleshooting

LAMPS FLASH 

TROUBLE CODE

PROBLEM

CAUSE

REMEDY

1 FLASH

No problem

Remote control entered into 

memory

Add any additional remote controls 

(MegaCode™ type only)

2 FLASHES

Door won’t close

Shorted wall station wires

Check wall station wires. Be sure both are 

connected to the terminal screws. Check for 

a staple in the wall station wires. Remove 

any staples compressing the wire.

3 FLASHES

Door won’t close

Safety beam obstacle

Check for obstacles. Align the safety beam 

(Section 11)

4 FLASHES

Door reverses 

or won’t open or 

close

Open or Close force exceeded, 

or motor thermal shutdown

Check for binding or un-balanced door. 

Adjust the door force (Section 14). If motor 

had thermal shutdown, wait 30 minutes and 

retry.

5 FLASHES

Door won’t open 

from transmitter

Remote was activated while 

vacation switch was locked

Unlock vacation switch on wall station

6 FLASHES

Motor ran longer 

than 30 seconds

Mechanical or electronic failure

Call Technical Services Group for assistance

FCC NOTICE

Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate 

the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  a  residential  installation. This  equipment 

generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•  Consult the dealer or an experienced radio/TV technician for help.

LIMITED WARRANTY

This Linear product is warranted to the original consumer against defects in material and workmanship for:

 

MODEL 

ELECTRONICS 

MECHANICAL 

MOTOR 

BELT

 

LSO50 

1 year 

5 years 

Lifetime 

Lifetime

This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will 

repair, or at its option, replace, any device that it finds requires service under this warranty, and will return the repaired or replaced device 

to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to damage to 

the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow Seller’s instructions, 

or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, punitive, 

consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the 

exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties 

implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts, 

so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary 

from state to state.
For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save 

your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require a Return 

Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

11  Aligning the Infrared Safety Beam

The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that 

travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the 

door is closing, the door will stop, then reverse and fully open (the operator’s light will flash three times).

As a safety feature, the operator will ignore signals from all remote controls if the door is open and the 

infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing 

and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

Safety Beam Test

1

  Check that the operator has power. The green lights on 

the sender and receiver should be lit.

2

  If the receiver’s green light is on, but the red light is off, 

the receiver has power but is not detecting the infrared 

beam from the sender. The red light might flash when 

the beam is partially detected. This can be caused by 

mis-alignment or something blocking the beam. Adjust 

the safety beam sender and receiver while watching the 

receiver’s red light (stay out of the beam while aligning 

it). When the red light stays on, the beam is aligned.

SAFETY BEAM INDICATOR TABLE

GREEN ON

POWER ON

GREEN OFF

POWER OFF

RED ON

BEAM OK - NO BLOCKAGE

RED OFF

BEAM BLOCKED OR MIS-ALIGNED

RED FLASHING

BEAM ALIGNED POORLY

➤ 

NOTE:

 If the receiver’s red light remains off, check 

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining 
into the receiver’s lens, 3) A short in the safety beam 
wiring (from staples or at the operator terminals).

3

 

With the door closed and the operator disengaged 

from  the  door,

  press  the  wall  station’s  UP/DOWN 

ARROW button to move the traveler (the part on the 

belt or chain that the trolley engages with) to the up 

position (away from the door).

4

  Push  the  wall  station’s  UP/DOWN  ARROW  button 

again.  While  the  traveler  is  moving  to  the  down 

position (toward the door), block the safety beam. 

THE 

TRAVELER MUST STOP, THEN REVERSE TO THE 

UP POSITION.

 The operator’s lights should flash three 

times.

5

  Place an object in the path of the safety beam. Check 

that constant pressure is required on the wall station’s 

UP/DOWN  ARROW  button  to  cause  the  traveler 

to  move  toward  the  down  position.  Release  the 

pushbutton 

before

 the operator stops; check that the 

traveler returns to the up position.

➤ 

NOTE:

 The  garage  door  operator  will  not  respond 

to a CLOSE command from a radio transmitter if the 
safety beam is blocked.

6

  To  reconnect  the  operator,  flip  the  release  lever 

up.  Raise  the  door  manually  until  the  operator 
reconnects.

12  Remote Controls

The operator is supplied with a three-button remote control (the second and third buttons can be used to control an 

additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote 

controls can be purchased. An unlimited number of remote controls can be used with this operator. The short white 

wire on the back of the operator serves as an antenna for the remote controls. Do not cut off the white wire or the 

remote controls will not operate well.

To Add a Remote Control

Press  the  operator’s  LEARN  button. The  red  LEARN 

light  will  glow. The  red  light  will  stay  on  for  about  15 

seconds. 

A  remote  must  be  added  while  the  red 

LEARN light is still on.

2

  Send a signal from a remote

The red LEARN light and 

the operator’s lights will flash once indicating that the 

operator has accepted the remote. 

3

  Repeat Steps 1 & 2 for any additional remote controls.

To Remove all Remote Controls

1

  Press and hold the operator’s LEARN button for ten 

seconds or more. 

2

  Release the LEARN button. 

The red LEARN light will 

blink three times signaling that all of the remotes 

in  the  operator’s  memory  were  erased. 

The  red 

LEARN light will turn off, then turn on for 15 seconds. 

A remote control can be entered during this time using 

Step 2 above.

Testing

1

  Before  testing  the  remote  control,  straighten  out  the 

operator’s white antenna wire so it points up.

2

 

Stand clear of the door,

 press the remote control’s 

button and verify that the operator starts. 

PRESS THE 

REMOTE  CONTROL’S  BUTTON  AGAIN TO  STOP 

THE DOOR MID-TRAVEL.

3

 

Set the open and close limits as described in the 

next section before any further testing.

Replacing a Remote Control’s Batteries

When  the  red  light  on  the  remote  glows  dimly,  or  fails 

to light at all when the remote is activated, the batteries 

need replacing.

1

  Open the remote’s case and remove the circuit board

2

  Replace old batteries with two Type 2032 batteries.

3

  Re-assemble the remote.

13  Adjusting the Open and Close Limits

The limit adjustments that control how far the door will 

open or close are located on the side of the operator. The 

limits should be adjusted so the door opens just short of 

any door stops, and closes right at the floor level. Each 

full turn of a limit adjustment equals about 2-½” of door 
travel.

1

 

If this is a jamb door installation, with the operator 

at  mid-travel,  turn  the  CLOSE  LIMIT  adjustment 

five turns in the UP direction before proceeding.

2

  Activate the remote control. Wait while the door moves 

to the open position and stops.

3

  Examine the position of the door.

  • If the door needs to open 

more

, turn the OPEN LIMIT 

adjustment clockwise ¼-turn (towards UP on the label) 

to raise the open limit.

  • If the door needs to open 

less

, turn the OPEN LIMIT 

adjustment counterclockwise ¼-turn (towards DOWN 

on the label) to lower the open limit.

➤ 

NOTE: 

On jamb doors, set the open limit so the door 

stops just short of level (see figure).

4

  Activate the remote control. Wait for the door to move 

down a few feet, then activate the remote control again 

to stop the door.

5

  Repeat  Steps  2-4  until  the  open  limit  is  properly 

adjusted.

6

  Activate the remote control. Wait while the door moves 

to the closed position and stops.

7

  Examine the position of the door.

  •  If  the  door  needs  to  close 

more

,  turn  the  CLOSE 

LIMIT  adjustment  counterclockwise  ¼-turn  (towards 

DOWN on the label) to lower the close limit.

  • If the door needs to close 

less

, turn the CLOSE LIMIT 

adjustment clockwise ¼-turn (towards UP on the label) 

to raise the close limit.

8

  Activate the remote control. Wait for the door to move 

up a few feet, then activate the remote control again to 

stop the door.

9

  Repeat Steps 6-8 until the close limit is properly adjusted.

➤ 

NOTE:

 If the door stops during opening or reverses 

during closing before reaching the limits, the door force 
adjustment needs to be set. Change the adjustment as 
described in the next section then return to this section 
to finish setting the limits.

14  Testing & Adjusting the Door Force Safety System

The door force adjustments are located on the side of the 

operator. 

The door force adjustments must be properly 

set at all times. 

The CLOSE FORCE adjustment controls 

how much force is required to cause the door to reverse 

direction if an obstruction is encountered during closing. 

The  OPEN  FORCE  adjustment  controls  how  much 

force  is  required  to  stop  the  door  if  an  obstruction  is 

encountered during opening.

➤ 

NOTE:

 Read the following directions carefully before 

setting the door force adjustments. 

Door Force Safety System Test

1

  Start with the door open. 

Use the remote control to 

cycle the door during these tests.

 

Adjusting the Close Force

2

  Turn the CLOSE FORCE adjustment 1/8-turn at a time 

in the DECREASE direction (counterclockwise) until the 

door stops and reverses mid travel while going down.

3

  Turn the CLOSE FORCE adjustment 1/8-turn at a time 

in the INCREASE direction (clockwise) until the door 

fully closes without reversing.

 

Safety Reversal System Test

4

  Lay a 2 x 4 board flat on the floor where it will be struck 

by the 

center

 of the door as it closes.

5

  Verify that the door reverses when it strikes the board. 

The  door 

must

  reverse  within  two  seconds  after 

striking the board.

➤ 

NOTE:

 If the door stops after encountering the board 

and does not reverse, the CLOSE FORCE needs to be 
DECREASED.

6

  Repeat the Safety Reversal System Test until the door 

reverses within two seconds of striking the board.

 

Adjusting the Open Force

7

  Turn the OPEN FORCE adjustment 1/8-turn at a time 

in  the  DECREASE  direction  (counterclockwise)  until 

the door stops mid travel while going up.

8

  Turn the OPEN FORCE adjustment 1/8-turn at a time 

in the INCREASE direction (clockwise) until the door 

fully opens without stopping.

PRINTER’S INSTRUCTIONS:

 

INSTR,INSTL,LSO W/MCT3; LINEAR P/N: 223711 A; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 17.000” x 22.000”; FOLDING: 2-FOLDS VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 2 OF 2 

  WARNING 

Children  operating  or  playing  with  a  garage 

door operator can injure themselves or others. 

The garage door could cause serious injury or 

death.  Do  not  allow  children  to  operate  the 

remote control(s) or the wall station. A moving 

garage door could injure or kill someone under 

it. Activate the operator only when the door is 

clearly visible, free of obstructions and adjusted 

properly.

  CAUTION 

Set the open and close limits carefully. Setting 

the limits beyond the distance that the door can 

travel could cause damage to the door, the door 

hardware, or operator.

  WARNING 

Too  much  door  force  will  interfere  with  the 

proper operation of the safety system. SOMEONE 

COULD BE SERIOUSLY INJURED OR KILLED IF THE 

DOOR  FORCE  IS  SET  TOO  HIGH.  A  closing  door 

might  not  reverse  properly  when  required  and 

someone could be pinned under it. An opening 

door might not stop when going up and someone 

hanging on the door could get pinned between 

the  door  and  the  header.  Do  not  increase  the 

door force beyond what is required to move the 

door. DO NOT USE THE DOOR FORCE ADJUSTMENT 

TO  COMPENSATE  FOR  A  BINDING  OR  STICKING 

GARAGE DOOR. PERFORM THE SAFETY REVERSAL 

SYSTEM TEST (STEPS 4-6) MONTHLY!

Copyright © 2004 Linear LLC 

223711 A

IMPORTANT USER SAFETY INSTRUCTIONS

  WARNING 

A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH! 

TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:

1  READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2  NEVER  LET  CHILDREN  OPERATE,  OR  PLAY WITH  DOOR  CONTROLS!  KEEP  REMOTE  CONTROL 

AWAY FROM CHILDREN!

3  Always keep moving door in sight and away from people and objects until it is completely closed. 

NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4  NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
5  Test door operator monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 

board laid flat at the center of the door) on the floor. If adjusting either the force or the limit of travel, 
re-test the door operator. Failure to adjust the operator properly may cause severe injury or death.

6  If possible, use the red emergency release handle only when the door is closed. Use caution when 

using this release with the door open. Weak or broken springs may cause the door to fall rapidly, 
causing injury or death.

7  KEEP  GARAGE  DOORS  PROPERLY  BALANCED.  (See  Garage  Door  Operator  Maintenance)  An 

improperly balanced door could cause severe injury or death. Have a qualified service person make 
repairs to cables, spring assembly and other hardware.

SAVE THESE INSTRUCTIONS.

SAFETY BEAM INDICATORS

RED LIGHT

GREEN LIGHT

GREEN LIGHT

ON = POWER ON
OFF = POWER OFF

RED LIGHT

ON = BEAM ALIGNED, NO OBSTRUCTION
OFF = BEAM NOT ALIGNED, OR OBSTRUCTION

BLINKING = BEAM NEEDS BETTER ALIGNMENT

ADJUST THE SENDER
AND RECEIVER UNTIL
THE RED INDICATOR
LIGHTS SOLID

ADJUSTING THE BEAM

BLOCK THE BEAM

WHILE THE TRAVELER

IS MOVING DOWN

TOWARD

DOOR

TOWARD
OPERATOR

UP

DOWN

CHECKING FOR REVERSAL

TRAVELER

THE TRAVELER MUST REVERSE

WHEN THE BEAM IS INTERRUPTED

PLACE AN OBJECT

IN THE BEAM'S PATH

VERIFY THAT CONSTANT

PRESSURE IS REQUIRED

ON THE WALL STATION'S

PUSHBUTTON TO MAKE

THE TRAVELER GO DOWN 

RELEASE PUSHBUTTON

BEFORE THE OPERATOR STOPS,

THE TRAVELER SHOULD

RETURN TO THE UP POSITION

CHECKING FORCED CLOSURE FEATURE

SEND A SIGNAL

FROM A REMOTE

THE OPERATOR'S LIGHTS AND

THE LEARN LIGHT WILL FLASH

ONCE WHEN THE REMOTE

HAS BEEN ACCEPTED

1

2

ADDING A REMOTE

PRESS A
BUTTON

- OR -

ENTER A CODE
AND PRESS

START/STOP

REMOVING ALL REMOTES

PRESS THE LEARN BUTTON
FOR 10 SECONDS OR MORE

THE LEARN LIGHT
WILL BLINK 3 TIMES

SIGNALING THAT

ALL REMOTES WERE
REMOVED

1

2

ADJUSTING THE

CLOSE FORCE

ADJUSTING THE

OPEN FORCE

SETTING THE DOOR FORCE

USE A SCREWDRIVER TO
ADJUST THE OPEN LIMIT

SETTING THE OPEN LIMIT

OPEN LIMIT

ADJUSTMENT

UP

DOWN

CLOSE LIMIT

ADJUSTMENT

UP

DOWN

USE A SCREWDRIVER TO
ADJUST THE CLOSE LIMIT

SETTING THE CLOSE LIMIT

DOWN

UP

EXAMINE THE SPOT WHERE
DOOR STOPS CLOSING

CHECKING WHERE THE DOOR STOPS

CLOSE FORCE

DECREASE

DECREASE CLOSE FORCE
ADJUSTMENT UNTIL THE

DOOR REVERSES MIDWAY

WHILE GOING DOWN

UNDER-SETTING THE CLOSE FORCE

DOWN

UP

EXAMINE THE SPOT WHERE
THE DOOR STOPS OPENING

CHECKING WHERE THE DOOR STOPS

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER

IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT
UNDER CENTER OF DOOR

TESTING THE SAFETY REVERSAL SYSTEM

PREPARING TO ADD A REMOTE

PRESS THE

LEARN
BUTTON

LEARN LIGHT WILL GLOW FOR
15 SECONDS, REMOTE MUST BE

ENTERED WHILE LEARN LIGHT IS ON

1

2

  WARNING 

With  the  door  closed,  disengage  the  trolley 

from the chain during these alignment tests by 

pulling the red release handle.

  WARNING 

Serious injury or death from a closing garage 

door may result because of failure to test and 

adjust safety reverse system. Repeat this test 

monthly and adjust as needed.

  WARNING 

The  garage  door  operator  must  not  be 

installed and used on an unbalanced door. The 

operator’s internal door force sensor will not 

function properly on an unbalanced door. Risk 

of serious injury or death may result.

  WARNING 

Garage  door  hardware  (springs,  cables, 

brackets,  pulleys,  etc.)  are  under  extreme 

pressure  and  tension.  DO  NOT  ATTEMPT  TO 

LOOSEN,  TIGHTEN  OR  ADJUST  ANY  DOOR 

HARDWARE.  CALL  A  QUALIFIED  GARAGE  DOOR 

INSTALLATION PROFESSIONAL!

  WARNING 

Always  perform  the  entire  Door  Force  Safety 

System Test (see Section 14) after making any 

adjustments to the operator.

1

TWIST DIME IN 
SLOT TO OPEN 
CASE

2

LIFT OFF
THE TOP OF
THE CASE

3

CAREFULLY
REMOVE THE
CIRCUIT BOARD

5

INSERT TWO NEW
TYPE 2032 BATTERIES

PLUS SIDE UP 

THEN

REASSEMBLE UNIT

NOTE: 

THE CIRCUIT BOARD WILL FIT ONLY ONE 

WAY INTO THE CASE. ALIGN THE PLASTIC POST 

IN THE CASE WITH THE HOLE IN THE CIRCUIT BOARD

REPLACING A REMOTE'S BATTERY

4

REMOVE OLD 
BATTERIES AND 
DISPOSE OF THEM PROPERLY

OPEN FORCE

DECREASE

DECREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR STOPS MIDWAY

WHILE GOING UP

OPEN FORCE

INCREASE

INCREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR OPENS FULLY

WITHOUT STOPPING

UNDER-SETTING THE OPEN FORCE

SETTING THE OPEN FORCE

CLOSE FORCE

INCREASE

INCREASE CLOSE FORCE
ADJUSTMENT UNTIL THE

DOOR CLOSES FULLY

WITHOUT REVERSING

SETTING THE CLOSE FORCE

PRESS THE

WALL STATION'S

UP/DOWN ARROW

PRESS A REMOTE

CONTROL BUTTON

OPENING OR CLOSING THE DOOR

- OR -

- OR -

ENTER AN

ACCESS CODE

AND PRESS

START/STOP

WALL STATION

REMOTE CONTROL

REMOTE

KEYPAD

WHENEVER OPERATING,
THE LIGHTS WILL TURN ON
FOR ABOUT 5 MINUTES

NOTE: FLASHING

LIGHTS INDICATE

TROUBLE

SAFETY LIGHTING

WALL

STATION

REMOTE

KEYPAD

REMOTE
CONTROL

THE DOOR CAN BE STOPPED

AT ANY POSITION USING THE

WALL STATION, REMOTE CONTROL,

OR A REMOTE KEYPAD

STOPPING THE DOOR

LOCK

UNLOCK

PREVENTING REMOTES

FROM OPENING THE DOOR

SLIDE THE VACATION SWITCH

DOWN TO LOCK (REMOTES DISABLED)

OR UP TO UNLOCK (REMOTES NORMAL)

CONTROLLING THE
OPERATOR'S LIGHTS

PRESS THE LIGHT
BUTTON TO TURN THE
LIGHTS ON OR OFF

THE LIGHTS WILL STAY ON UNTIL
THE LIGHT BUTTON IS PRESSED
OR THE OPERATOR IS CYCLED

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IN CASE OF POWER FAILURE

OR IF DOOR BECOMES OBSTRUCTED

PULL THE RED
RELEASE HANDLE

TO DISCONNECT
THE OPERATOR
FROM THE

DOOR

FLIP THE LEVER UP
AND RAISE OR
LOWER THE DOOR
TO RECONNECT
THE OPERATOR

TURNBUCKLE
LOCKNUTS

TO HEAD LOCKNUTS

TIGHTEN

LOCKNUTS

LOOSEN

HOLD TURNBUCKLE
WITH FLAT BLADE
SCREWDRIVER TO
BACKUP LOCKNUTS

TWIST

TURNBUCKLE

CHAIN

TIGHTEN CHAIN

LOOSEN

ADJUSTING A CHAIN-DRIVE

ADJUSTING A BELT-DRIVE

TIGHTEN

LOOSEN

TURN THE ADJUSTMENT
WHEEL UNTIL THE TENSION
SPRING IS ABOUT 1" LONG

ADJUSTMENT WHEEL

MEASURE THE TENSION
SPRING LENGTH

TRAVELER

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

TO DISCONNECT OPERATOR

PULL THE RED
RELEASE HANDLE

TO DISCONNECT
THE OPERATOR
FROM THE

DOOR

FLIP THE LEVER UP
AND RAISE OR

LOWER THE DOOR
TO RECONNECT
THE OPERATOR

TO RECONNECT OPERATOR

  WARNING 

Always perform the Door Force Safety System Test 

after making any adjustments to the operator.

SETTING THE OPEN LIMIT ON A JAMB DOOR

JAMB DOOR

SET THE OPEN LIMIT SO THE DOOR
STOPS JUST SHORT OF LEVEL

NOTE: SETTING THE OPEN LIMIT TOO HIGH WILL CAUSE
THE OPERATOR TO "BUCK" WHEN STARTING DOWN

Reviews: