15 Using the Garage Door Operator
Opening the Door
1
With the door in view, press the wall station’s UP/
DOWN ARROW button or the button assigned to the
operator on the remote control, or enter a valid access
code and press START/STOP on a remote keypad.
2
When the operator is activated, the operator’s lights
will turn on and the door will begin to open.
3
The door will open until the open limit is reached. If
an obstacle is encountered (operator’s lights flash four
times) while the door is opening, the door will stop.
4
The operator’s lights will stay on for about five minutes
after the door stops.
Closing the Door
1
With the door in view, press the wall station’s UP/
DOWN ARROW button or the button assigned to the
operator on the remote control, or enter a valid access
code and press START/STOP on a remote keypad.
2
When the operator is activated, the operator’s lights
will turn on and the door will begin to close.
3
The door will close until the close limit is reached. If
an obstacle is encountered (operator’s lights flash four
times), or the safety beam is interrupted (operator’s
lights flash three times) during closing, the door will
stop, then re-open.
4
The operator’s lights will stay on for about five minutes
after the door stops.
Stopping the Door Mid-travel
1
The door can be stopped immediately at any time
by pressing the wall station’s UP/DOWN ARROW
button, the remote control’s pushbutton, or press
the START/STOP button on a remote keypad.
2
The next time the operator is activated, the door will
move in the opposite direction.
Vacation Lock for Additional Security
1
Slide the wall station’s LOCK switch to the locked
position to prevent remote controls from opening the
door after the door is completely closed. The remotes
can close the door, but not open it. The door can
still be opened or closed by using the wall station’s
UP/DOWN ARROW pushbutton.
➤
NOTE:
To signal that the vacation switch is locked,
the operator’s lights will flash five times if a remote is
activated in an attempt to open the door.
2
Slide the wall station’s LOCK switch to the unlocked
position to return the operator to normal operation.
Controlling the Operator’s Lights
1
The operator’s lights can be lit by pushing the wall
station’s LIGHT button. The lights will remain on until
the LIGHT button is pressed again or the operator is
cycled.
2
If the operator’s lights are on, pushing the wall station’s
LIGHT button will turn the operator’s lights off.
Disconnecting the Door from the Operator
1
With the door in any position (preferably closed),
carefully pull the red release handle.
USE CAUTION
IF THE DOOR IS OPEN, THE DOOR MAY DROP.
2
The disconnected door can be opened or closed
manually.
3
To re-connect the operator, flip the release lever up.
Raise or lower the door manually until the operator
reconnects.
16 Garage Door Operator Maintenance
Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments.
Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To
insure safe operation of the door, perform the following tests, including any additional test steps described.
Every Month
1
With the door closed, pull the red release handle to
disconnect the operator from the door.
2
From outside the garage, slowly open the door
manually all the way, and then close it all the way.
Notice if there is any binding, sticking or rubbing. The
door should move smoothly in both directions.
3
Raise the garage door about halfway up. Carefully
release the door and see if the door balances. It should
stay in place. Close the door.
➤
NOTE:
If the garage door is unbalanced or the
door travel isn’t smooth, have a qualified garage door
professional adjust or repair the door.
4
To reconnect the operator, flip the release lever
up. Raise the door manually until the operator
reconnects.
5
Perform the Safety Beam Test (Section 11).
6
Perform the Safety Reversal System Test as described
in Steps 4-6 in Section 14.
After Servicing the Operator
1
Perform the Safety Beam Test (Section 11).
2
Perform the Open and Close Limit Adjustments
(Section 13).
3
Perform the entire Door Force Safety System Test
(Section 14).
Every 6 Months
Check the belt or chain tension.
• For belt-drive rails, examine the length of the tension
spring in the traveler. It should be about 1” long.
• For chain-drive rails, examine the spacing between
the turnbuckle and the rail. The turnbuckle should be
slightly above the rail.
➤
NOTE:
Too much or too little chain tension will cause
excessive sprocket noise.
Chain Adjustment
If necessary, use the following steps to adjust the chain.
1
Hold the turnbuckle with a flat blade screwdriver and
loosen the two locknuts with a 7/16” end wrench.
2
Twist the turnbuckle to adjust the chain tension. Adjust
the chain until the turnbuckle is sightly above the rail.
3
Hold the turnbuckle with a flat blade screwdriver and
tighten the two locknuts with a 7/16” end wrench.
Belt Adjustment
The tension spring in the traveler keeps the belt taut. The
factory setting for the tension spring length is .9” long. If
the tension spring is longer than 1”, adjust the belt.
1
Hold the traveler so the adjustment wheel is visible
through the large slot.
2
Use a flat blade screwdriver to turn the adjustment
wheel to compress the tension spring until its length is
between .9” and 1” long.
Every Year
Check the door hardware for lubrication needs. Lubricate
door hinges, rollers and bearings according to door
manufacturer’s recommended procedures.
17 Troubleshooting
LAMPS FLASH
TROUBLE CODE
PROBLEM
CAUSE
REMEDY
1 FLASH
No problem
Remote control entered into
memory
Add any additional remote controls
(MegaCode™ type only)
2 FLASHES
Door won’t close
Shorted wall station wires
Check wall station wires. Be sure both are
connected to the terminal screws. Check for
a staple in the wall station wires. Remove
any staples compressing the wire.
3 FLASHES
Door won’t close
Safety beam obstacle
Check for obstacles. Align the safety beam
(Section 11)
4 FLASHES
Door reverses
or won’t open or
close
Open or Close force exceeded,
or motor thermal shutdown
Check for binding or un-balanced door.
Adjust the door force (Section 14). If motor
had thermal shutdown, wait 30 minutes and
retry.
5 FLASHES
Door won’t open
from transmitter
Remote was activated while
vacation switch was locked
Unlock vacation switch on wall station
6 FLASHES
Motor ran longer
than 30 seconds
Mechanical or electronic failure
Call Technical Services Group for assistance
FCC NOTICE
Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate
the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
LIMITED WARRANTY
This Linear product is warranted to the original consumer against defects in material and workmanship for:
MODEL
ELECTRONICS
MECHANICAL
MOTOR
BELT
LSO50
1 year
5 years
Lifetime
Lifetime
This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will
repair, or at its option, replace, any device that it finds requires service under this warranty, and will return the repaired or replaced device
to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to damage to
the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow Seller’s instructions,
or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, punitive,
consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the
exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties
implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save
your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require a Return
Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
11 Aligning the Infrared Safety Beam
The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that
travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the
door is closing, the door will stop, then reverse and fully open (the operator’s light will flash three times).
As a safety feature, the operator will ignore signals from all remote controls if the door is open and the
infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing
and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).
Safety Beam Test
1
Check that the operator has power. The green lights on
the sender and receiver should be lit.
2
If the receiver’s green light is on, but the red light is off,
the receiver has power but is not detecting the infrared
beam from the sender. The red light might flash when
the beam is partially detected. This can be caused by
mis-alignment or something blocking the beam. Adjust
the safety beam sender and receiver while watching the
receiver’s red light (stay out of the beam while aligning
it). When the red light stays on, the beam is aligned.
SAFETY BEAM INDICATOR TABLE
GREEN ON
POWER ON
GREEN OFF
POWER OFF
RED ON
BEAM OK - NO BLOCKAGE
RED OFF
BEAM BLOCKED OR MIS-ALIGNED
RED FLASHING
BEAM ALIGNED POORLY
➤
NOTE:
If the receiver’s red light remains off, check
for: 1) Dirt on the receiver’s lens, 2) Sunlight shining
into the receiver’s lens, 3) A short in the safety beam
wiring (from staples or at the operator terminals).
3
With the door closed and the operator disengaged
from the door,
press the wall station’s UP/DOWN
ARROW button to move the traveler (the part on the
belt or chain that the trolley engages with) to the up
position (away from the door).
4
Push the wall station’s UP/DOWN ARROW button
again. While the traveler is moving to the down
position (toward the door), block the safety beam.
THE
TRAVELER MUST STOP, THEN REVERSE TO THE
UP POSITION.
The operator’s lights should flash three
times.
5
Place an object in the path of the safety beam. Check
that constant pressure is required on the wall station’s
UP/DOWN ARROW button to cause the traveler
to move toward the down position. Release the
pushbutton
before
the operator stops; check that the
traveler returns to the up position.
➤
NOTE:
The garage door operator will not respond
to a CLOSE command from a radio transmitter if the
safety beam is blocked.
6
To reconnect the operator, flip the release lever
up. Raise the door manually until the operator
reconnects.
12 Remote Controls
The operator is supplied with a three-button remote control (the second and third buttons can be used to control an
additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote
controls can be purchased. An unlimited number of remote controls can be used with this operator. The short white
wire on the back of the operator serves as an antenna for the remote controls. Do not cut off the white wire or the
remote controls will not operate well.
To Add a Remote Control
1
Press the operator’s LEARN button. The red LEARN
light will glow. The red light will stay on for about 15
seconds.
A remote must be added while the red
LEARN light is still on.
2
Send a signal from a remote
.
The red LEARN light and
the operator’s lights will flash once indicating that the
operator has accepted the remote.
3
Repeat Steps 1 & 2 for any additional remote controls.
To Remove all Remote Controls
1
Press and hold the operator’s LEARN button for ten
seconds or more.
2
Release the LEARN button.
The red LEARN light will
blink three times signaling that all of the remotes
in the operator’s memory were erased.
The red
LEARN light will turn off, then turn on for 15 seconds.
A remote control can be entered during this time using
Step 2 above.
Testing
1
Before testing the remote control, straighten out the
operator’s white antenna wire so it points up.
2
Stand clear of the door,
press the remote control’s
button and verify that the operator starts.
PRESS THE
REMOTE CONTROL’S BUTTON AGAIN TO STOP
THE DOOR MID-TRAVEL.
3
Set the open and close limits as described in the
next section before any further testing.
Replacing a Remote Control’s Batteries
When the red light on the remote glows dimly, or fails
to light at all when the remote is activated, the batteries
need replacing.
1
Open the remote’s case and remove the circuit board
2
Replace old batteries with two Type 2032 batteries.
3
Re-assemble the remote.
13 Adjusting the Open and Close Limits
The limit adjustments that control how far the door will
open or close are located on the side of the operator. The
limits should be adjusted so the door opens just short of
any door stops, and closes right at the floor level. Each
full turn of a limit adjustment equals about 2-½” of door
travel.
1
If this is a jamb door installation, with the operator
at mid-travel, turn the CLOSE LIMIT adjustment
five turns in the UP direction before proceeding.
2
Activate the remote control. Wait while the door moves
to the open position and stops.
3
Examine the position of the door.
• If the door needs to open
more
, turn the OPEN LIMIT
adjustment clockwise ¼-turn (towards UP on the label)
to raise the open limit.
• If the door needs to open
less
, turn the OPEN LIMIT
adjustment counterclockwise ¼-turn (towards DOWN
on the label) to lower the open limit.
➤
NOTE:
On jamb doors, set the open limit so the door
stops just short of level (see figure).
4
Activate the remote control. Wait for the door to move
down a few feet, then activate the remote control again
to stop the door.
5
Repeat Steps 2-4 until the open limit is properly
adjusted.
6
Activate the remote control. Wait while the door moves
to the closed position and stops.
7
Examine the position of the door.
• If the door needs to close
more
, turn the CLOSE
LIMIT adjustment counterclockwise ¼-turn (towards
DOWN on the label) to lower the close limit.
• If the door needs to close
less
, turn the CLOSE LIMIT
adjustment clockwise ¼-turn (towards UP on the label)
to raise the close limit.
8
Activate the remote control. Wait for the door to move
up a few feet, then activate the remote control again to
stop the door.
9
Repeat Steps 6-8 until the close limit is properly adjusted.
➤
NOTE:
If the door stops during opening or reverses
during closing before reaching the limits, the door force
adjustment needs to be set. Change the adjustment as
described in the next section then return to this section
to finish setting the limits.
14 Testing & Adjusting the Door Force Safety System
The door force adjustments are located on the side of the
operator.
The door force adjustments must be properly
set at all times.
The CLOSE FORCE adjustment controls
how much force is required to cause the door to reverse
direction if an obstruction is encountered during closing.
The OPEN FORCE adjustment controls how much
force is required to stop the door if an obstruction is
encountered during opening.
➤
NOTE:
Read the following directions carefully before
setting the door force adjustments.
Door Force Safety System Test
1
Start with the door open.
Use the remote control to
cycle the door during these tests.
Adjusting the Close Force
2
Turn the CLOSE FORCE adjustment 1/8-turn at a time
in the DECREASE direction (counterclockwise) until the
door stops and reverses mid travel while going down.
3
Turn the CLOSE FORCE adjustment 1/8-turn at a time
in the INCREASE direction (clockwise) until the door
fully closes without reversing.
Safety Reversal System Test
4
Lay a 2 x 4 board flat on the floor where it will be struck
by the
center
of the door as it closes.
5
Verify that the door reverses when it strikes the board.
The door
must
reverse within two seconds after
striking the board.
➤
NOTE:
If the door stops after encountering the board
and does not reverse, the CLOSE FORCE needs to be
DECREASED.
6
Repeat the Safety Reversal System Test until the door
reverses within two seconds of striking the board.
Adjusting the Open Force
7
Turn the OPEN FORCE adjustment 1/8-turn at a time
in the DECREASE direction (counterclockwise) until
the door stops mid travel while going up.
8
Turn the OPEN FORCE adjustment 1/8-turn at a time
in the INCREASE direction (clockwise) until the door
fully opens without stopping.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,LSO W/MCT3; LINEAR P/N: 223711 A; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 17.000” x 22.000”; FOLDING: 2-FOLDS VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 2 OF 2
WARNING
Children operating or playing with a garage
door operator can injure themselves or others.
The garage door could cause serious injury or
death. Do not allow children to operate the
remote control(s) or the wall station. A moving
garage door could injure or kill someone under
it. Activate the operator only when the door is
clearly visible, free of obstructions and adjusted
properly.
CAUTION
Set the open and close limits carefully. Setting
the limits beyond the distance that the door can
travel could cause damage to the door, the door
hardware, or operator.
WARNING
Too much door force will interfere with the
proper operation of the safety system. SOMEONE
COULD BE SERIOUSLY INJURED OR KILLED IF THE
DOOR FORCE IS SET TOO HIGH. A closing door
might not reverse properly when required and
someone could be pinned under it. An opening
door might not stop when going up and someone
hanging on the door could get pinned between
the door and the header. Do not increase the
door force beyond what is required to move the
door. DO NOT USE THE DOOR FORCE ADJUSTMENT
TO COMPENSATE FOR A BINDING OR STICKING
GARAGE DOOR. PERFORM THE SAFETY REVERSAL
SYSTEM TEST (STEPS 4-6) MONTHLY!
Copyright © 2004 Linear LLC
223711 A
IMPORTANT USER SAFETY INSTRUCTIONS
WARNING
A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!
TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:
1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2 NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL
AWAY FROM CHILDREN!
3 Always keep moving door in sight and away from people and objects until it is completely closed.
NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
5 Test door operator monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4
board laid flat at the center of the door) on the floor. If adjusting either the force or the limit of travel,
re-test the door operator. Failure to adjust the operator properly may cause severe injury or death.
6 If possible, use the red emergency release handle only when the door is closed. Use caution when
using this release with the door open. Weak or broken springs may cause the door to fall rapidly,
causing injury or death.
7 KEEP GARAGE DOORS PROPERLY BALANCED. (See Garage Door Operator Maintenance) An
improperly balanced door could cause severe injury or death. Have a qualified service person make
repairs to cables, spring assembly and other hardware.
8
SAVE THESE INSTRUCTIONS.
SAFETY BEAM INDICATORS
RED LIGHT
GREEN LIGHT
GREEN LIGHT
ON = POWER ON
OFF = POWER OFF
RED LIGHT
ON = BEAM ALIGNED, NO OBSTRUCTION
OFF = BEAM NOT ALIGNED, OR OBSTRUCTION
BLINKING = BEAM NEEDS BETTER ALIGNMENT
ADJUST THE SENDER
AND RECEIVER UNTIL
THE RED INDICATOR
LIGHTS SOLID
ADJUSTING THE BEAM
BLOCK THE BEAM
WHILE THE TRAVELER
IS MOVING DOWN
TOWARD
DOOR
TOWARD
OPERATOR
UP
DOWN
CHECKING FOR REVERSAL
TRAVELER
THE TRAVELER MUST REVERSE
WHEN THE BEAM IS INTERRUPTED
PLACE AN OBJECT
IN THE BEAM'S PATH
VERIFY THAT CONSTANT
PRESSURE IS REQUIRED
ON THE WALL STATION'S
PUSHBUTTON TO MAKE
THE TRAVELER GO DOWN
RELEASE PUSHBUTTON
BEFORE THE OPERATOR STOPS,
THE TRAVELER SHOULD
RETURN TO THE UP POSITION
CHECKING FORCED CLOSURE FEATURE
SEND A SIGNAL
FROM A REMOTE
THE OPERATOR'S LIGHTS AND
THE LEARN LIGHT WILL FLASH
ONCE WHEN THE REMOTE
HAS BEEN ACCEPTED
1
2
ADDING A REMOTE
PRESS A
BUTTON
- OR -
ENTER A CODE
AND PRESS
START/STOP
REMOVING ALL REMOTES
PRESS THE LEARN BUTTON
FOR 10 SECONDS OR MORE
THE LEARN LIGHT
WILL BLINK 3 TIMES
SIGNALING THAT
ALL REMOTES WERE
REMOVED
1
2
ADJUSTING THE
CLOSE FORCE
ADJUSTING THE
OPEN FORCE
SETTING THE DOOR FORCE
USE A SCREWDRIVER TO
ADJUST THE OPEN LIMIT
SETTING THE OPEN LIMIT
OPEN LIMIT
ADJUSTMENT
UP
DOWN
CLOSE LIMIT
ADJUSTMENT
UP
DOWN
USE A SCREWDRIVER TO
ADJUST THE CLOSE LIMIT
SETTING THE CLOSE LIMIT
DOWN
UP
EXAMINE THE SPOT WHERE
DOOR STOPS CLOSING
CHECKING WHERE THE DOOR STOPS
CLOSE FORCE
DECREASE
DECREASE CLOSE FORCE
ADJUSTMENT UNTIL THE
DOOR REVERSES MIDWAY
WHILE GOING DOWN
UNDER-SETTING THE CLOSE FORCE
DOWN
UP
EXAMINE THE SPOT WHERE
THE DOOR STOPS OPENING
CHECKING WHERE THE DOOR STOPS
TEST WITH SMALL OBSTACLE
THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER
IMPACT WITH A 2 x 4 BOARD
2 x 4 BOARD LAID FLAT
UNDER CENTER OF DOOR
TESTING THE SAFETY REVERSAL SYSTEM
PREPARING TO ADD A REMOTE
PRESS THE
LEARN
BUTTON
LEARN LIGHT WILL GLOW FOR
15 SECONDS, REMOTE MUST BE
ENTERED WHILE LEARN LIGHT IS ON
1
2
WARNING
With the door closed, disengage the trolley
from the chain during these alignment tests by
pulling the red release handle.
WARNING
Serious injury or death from a closing garage
door may result because of failure to test and
adjust safety reverse system. Repeat this test
monthly and adjust as needed.
WARNING
The garage door operator must not be
installed and used on an unbalanced door. The
operator’s internal door force sensor will not
function properly on an unbalanced door. Risk
of serious injury or death may result.
WARNING
Garage door hardware (springs, cables,
brackets, pulleys, etc.) are under extreme
pressure and tension. DO NOT ATTEMPT TO
LOOSEN, TIGHTEN OR ADJUST ANY DOOR
HARDWARE. CALL A QUALIFIED GARAGE DOOR
INSTALLATION PROFESSIONAL!
WARNING
Always perform the entire Door Force Safety
System Test (see Section 14) after making any
adjustments to the operator.
1
TWIST DIME IN
SLOT TO OPEN
CASE
2
LIFT OFF
THE TOP OF
THE CASE
3
CAREFULLY
REMOVE THE
CIRCUIT BOARD
5
INSERT TWO NEW
TYPE 2032 BATTERIES
PLUS SIDE UP
THEN
REASSEMBLE UNIT
NOTE:
THE CIRCUIT BOARD WILL FIT ONLY ONE
WAY INTO THE CASE. ALIGN THE PLASTIC POST
IN THE CASE WITH THE HOLE IN THE CIRCUIT BOARD
REPLACING A REMOTE'S BATTERY
4
REMOVE OLD
BATTERIES AND
DISPOSE OF THEM PROPERLY
OPEN FORCE
DECREASE
DECREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR STOPS MIDWAY
WHILE GOING UP
OPEN FORCE
INCREASE
INCREASE OPEN FORCE
ADJUSTMENT UNTIL THE
DOOR OPENS FULLY
WITHOUT STOPPING
UNDER-SETTING THE OPEN FORCE
SETTING THE OPEN FORCE
CLOSE FORCE
INCREASE
INCREASE CLOSE FORCE
ADJUSTMENT UNTIL THE
DOOR CLOSES FULLY
WITHOUT REVERSING
SETTING THE CLOSE FORCE
PRESS THE
WALL STATION'S
UP/DOWN ARROW
PRESS A REMOTE
CONTROL BUTTON
OPENING OR CLOSING THE DOOR
- OR -
- OR -
ENTER AN
ACCESS CODE
AND PRESS
START/STOP
WALL STATION
REMOTE CONTROL
REMOTE
KEYPAD
WHENEVER OPERATING,
THE LIGHTS WILL TURN ON
FOR ABOUT 5 MINUTES
NOTE: FLASHING
LIGHTS INDICATE
TROUBLE
SAFETY LIGHTING
WALL
STATION
REMOTE
KEYPAD
REMOTE
CONTROL
THE DOOR CAN BE STOPPED
AT ANY POSITION USING THE
WALL STATION, REMOTE CONTROL,
OR A REMOTE KEYPAD
STOPPING THE DOOR
LOCK
UNLOCK
PREVENTING REMOTES
FROM OPENING THE DOOR
SLIDE THE VACATION SWITCH
DOWN TO LOCK (REMOTES DISABLED)
OR UP TO UNLOCK (REMOTES NORMAL)
CONTROLLING THE
OPERATOR'S LIGHTS
PRESS THE LIGHT
BUTTON TO TURN THE
LIGHTS ON OR OFF
THE LIGHTS WILL STAY ON UNTIL
THE LIGHT BUTTON IS PRESSED
OR THE OPERATOR IS CYCLED
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
IN CASE OF POWER FAILURE
OR IF DOOR BECOMES OBSTRUCTED
PULL THE RED
RELEASE HANDLE
TO DISCONNECT
THE OPERATOR
FROM THE
DOOR
FLIP THE LEVER UP
AND RAISE OR
LOWER THE DOOR
TO RECONNECT
THE OPERATOR
TURNBUCKLE
LOCKNUTS
TO HEAD LOCKNUTS
TIGHTEN
LOCKNUTS
LOOSEN
HOLD TURNBUCKLE
WITH FLAT BLADE
SCREWDRIVER TO
BACKUP LOCKNUTS
TWIST
TURNBUCKLE
CHAIN
TIGHTEN CHAIN
LOOSEN
ADJUSTING A CHAIN-DRIVE
ADJUSTING A BELT-DRIVE
TIGHTEN
LOOSEN
TURN THE ADJUSTMENT
WHEEL UNTIL THE TENSION
SPRING IS ABOUT 1" LONG
ADJUSTMENT WHEEL
MEASURE THE TENSION
SPRING LENGTH
TRAVELER
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
TO DISCONNECT OPERATOR
PULL THE RED
RELEASE HANDLE
TO DISCONNECT
THE OPERATOR
FROM THE
DOOR
FLIP THE LEVER UP
AND RAISE OR
LOWER THE DOOR
TO RECONNECT
THE OPERATOR
TO RECONNECT OPERATOR
WARNING
Always perform the Door Force Safety System Test
after making any adjustments to the operator.
SETTING THE OPEN LIMIT ON A JAMB DOOR
JAMB DOOR
SET THE OPEN LIMIT SO THE DOOR
STOPS JUST SHORT OF LEVEL
NOTE: SETTING THE OPEN LIMIT TOO HIGH WILL CAUSE
THE OPERATOR TO "BUCK" WHEN STARTING DOWN