Mid-Stop

: Activation stops an opening door; momentary contact 

of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 

Auto Close Timer

: N/A 

TS Operation 

Open Button

: Momentary activation; open override of closing 

door. 

Close Button

: Momentary activation. 

Stop Button

: Momentary activation; stops open, close or reverse 

action. 

Single Button

: Momentary activation to open; open override of 

closing door, closes door from mid-stop or open limit. 

EP Reverse (Photo Input)

: Momentary activation will reverse a 

closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 

Mid-Stop

: Activation stops an opening door; momentary contact 

of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 

Auto Close Timer

: Closes door from mid-stop or open limit 

after pre-set time. Stop will deactivate the auto close timer. 
Open will reactivate the auto close timer or reset the auto close 
timer when the door is at the mid-stop or open limit. Single 
button will reset the auto close timer from the mid-stop or open 
limit. Reverse will reactivate the auto close timer or reset the 
auto close timer when the door is at the mid-stop or open limit. 

T Operation, Dip-Switch Setting 

Open Button

: Momentary activation; open override of closing 

door. 

Close Button

: Momentary activation. 

Stop Button

: Momentary activation; stops open, close or reverse 

action. 

Single Button

: Momentary activation to open; open override of 

closing door, closes door from mid-stop or open limit. 

EP Reverse (Photo Input)

: Momentary activation will reverse a 

closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 

Mid-Stop

: Activation stops an opening door; momentary contact 

of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 

Auto Close Timer

: Closes door from mid-stop or open limit 

after pre-set time. Stop will deactivate the auto close timer. 
Open will reactivate the auto close timer or reset the auto close 
timer when the door is at the open limit. Single button will reset 
the auto close timer from the mid-stop or open limit. Reverse 
deactivates the auto close timer if the door is closing. Reverse 
will reset the auto close timer at the mid-stop or open limit if 
the auto close timer has not been previously deactivated. 

SETUP MODES

 

Setup Modes 

Various operating characteristics can be modified via the setup 
modes. The operator is moved to the close limit position and 
the on-board dip switches (see Figure 14, page 15) are 

TEMPORARILY

 set according to the table at right to enter a 

Setup Mode. The on board OPEN and STOP buttons are used 
to modify the characteristic. Once set, the values are stored in 
non-volatile memory.   
These values are set to factory defaults that should be 
satisfactory for many applications. All values as described here 
can be reset to the factory defaults as follows: 

 

Remove 24 VAC power from the control board. 

 

Press and hold the on-board stop button. 

 

Re-apply 24 VAC while holding the on-board stop button. 

After completing the procedure to modify the operating 

characteristic the switches must be returned to the originally set 
Operating Mode setting (see section previous). 

 

Delay on Reverse Setup 

To help prevent stress on the door components, this feature 

allows for a delay time between the door stopping and reversing 
when a command to reverse is received as the door is closing.  
The factory default time is 0.75 seconds; the minimum time is 
0.4 seconds; the maximum time is 2 seconds.  

After moving the door to the close position and 

temporarily

 

setting the switches to the appropriate settings in the table,  
pressing STOP will reset the time to the minimum setting. 

Every time OPEN is pressed, 200 mS is added to the time (up to 

the maximum). 

Changing the dip-switch setting to any other setting will save 

the new time.  Return the dip switches to the originally set 
Operating Mode setting (see section previous). 

 

Close Limit Delay Setup 

To provide for irregularities in the floor, this feature allows for 

the door to continue to travel down after the Reverse Cutout 
Limit is activated.  The factory default time is 0.32 seconds; the 
minimum time is 0.12 seconds; the maximum time is 0.66 
seconds. 

After moving the door to the close position and 

temporarily

 

setting the switches to the appropriate settings in the table,  
pressing STOP will reset the time to the minimum setting. 

Every time OPEN is pressed, 0.02 seconds are added to the time 

(up to the maximum). 

Changing the dip-switch setting to any other setting will save 

the new time.  Return the dip switches to the originally set 
Operating Mode setting (see section previous). 

Setup Mode

 

Switch 1

 

Switch 2

 

Switch 3

 

Switch 4

 

Delay on Reverse 

ON 

ON 

ON 

ON 

Close Limit Delay 

OFF 

ON 

ON 

ON 

Mid-Stop Limit 

ON 

OFF 

ON 

ON 

Auto Close Timer 

OFF 

OFF 

ON 

ON 

Maximum Run Time 

OFF 

ON 

OFF 

ON 

OPERATION & ADJUSTMENT INSTRUCTIONS 

17 

Summary of Contents for H-S

Page 1: ...operators J S H S J H SERIES WITH SOLID STATE CONTROL CIRCUITRY JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date...

Page 2: ...on 5 Table 1 Component Identification Listing 5 Installation Instructions 6 13 Figure 2 Operator Footprint J S H S 6 Figure 5 Release Hand Chain Wall Bracket Installation 7 Figure 6 Mounting Positions...

Page 3: ...hoto beam are provided Constant Contact To Close Standard operating mode The operator can be converted to Momentary Contact To Close when the photo beam as described above or one of the Miller Edge fa...

Page 4: ...ing carton inspect the nameplate on the cover of the operator control box to verify that it is the correct model for the intended application and that the voltage and phase are in accordance with elec...

Page 5: ...pedestrian door is available for entrance and exit to the building In addition YOU MUST install an auxiliary entrapment protection device reversing door edge or photoelectric beam device Connect an au...

Page 6: ...inch diameter bolts through the wall If it is not feasible to go through the wall then use lag bolts to fasten the operator to the mounting surface Locate the four holes within the tracings of the slo...

Page 7: ...chain is too long standard length for 16 foot high doors and below is 26 feet total length of chain shorten it to the desired length using the method described above and discard the unused portion Fa...

Page 8: ...Figure 6 100719 Right Side Mount Ceiling Mount Left Side Mount Ceiling Mount Center Mount Direct Couple Wall Mount Wall Mount 8 FIGURE 4 OPERATOR MOUNTING POSITIONS...

Page 9: ...107841 Figure 7 Dimensions Model H S Figure 7A Dimensions Model J S 108203 9 FIGURE 5 OPERATOR DIMENSIONS MODEL J S H S...

Page 10: ...ut switch closer to the center of the box will increase the point where the reversing feature cuts out to allow for irregularity in the floor etc The reverse cutout point is factory adjusted to approx...

Page 11: ...vices exactly as shown Warning Control voltage of the opener is 5 volts DC Class 2 Do not run the power leads and control circuit wiring in the same electrical conduit Note J S and H S Series model op...

Page 12: ...USE AN INTERLOCK SWITCH IF A LOCK IS REQUIRED TO RETAIN FUNCTIONALTY CAUTION Figure 8 Door Edge Device Note See the door edge manufacturer s installation instructions for the complete installation pr...

Page 13: ...n of this device will not enable the Momentary Contact to Open Mode Any Miller Edge ME MT MU and CPT family of edges must be connected to the SM 102 Edge Module Recognized by UL as per UL325 2010 on 0...

Page 14: ...y is clear Figure 11 PCB 112695 REV B TSLK OPEN C25 PB1 PB2 PB3 U5 STOP CLOSE OPEN C1 R84 R2 R3 D12 COM CLOSE STOP NO REV NC REV PHOTO MOTOR CONTROL BOARD Single 3 Button Station MOTOR CONTROL BOARD C...

Page 15: ...over adjust the force setting to compensate for a poorly working door To prevent the motor protector from tripping Do not exceed 10 door cycles per hour IMPORTANT The hardware box contains a caution l...

Page 16: ...open button will bypass mid stop Auto Close Timer N A D1 Operation Open Button Constant activation open override of closing door Close Button Constant activation door will stop when button is release...

Page 17: ...limit if the auto close timer has not been previously deactivated SETUP MODES Setup Modes Various operating characteristics can be modified via the setup modes The operator is moved to the close limi...

Page 18: ...lose Timer Setup This feature allows for a modification of the amount of time between the door reaching either the Mid Stop or the Full Open position and automatically starting in the close direction...

Page 19: ...RDWARE BINDING IN THE TRACK RUBBING AGAINST THE DOOR STOPS OR DEFECTIVE OR MISADJUSTED SPRINGS ANY SERVICE REQUIRED TO THE DOOR DOOR SPRINGS OR DOOR OPERATOR MUST BE PREFORMED BY A QUALIFIED PROFESSIO...

Page 20: ...OPERATION ADJUSTMENT INSTRUCTIONS 20...

Page 21: ...ON DO NOT STAND UNDER DOOR TO TEST REVERSING FEATURE USE A CORRUGATED BOX OR OTHER SIMILAR OBJECT If the operator is equipped with other means of control such as additional 3 button stations or radio...

Page 22: ...OR DIRECTION SWITCH INCOMING LEADS TO TERMINALS 5 AND 8 DUAL VOLTAGE MOTOR 230V 1P RED AU BLUE T J H WHITE 4 8 BALDOR YELLOW 5 1 2 3 BRAKE BL BLK BL BLK CDOMCB 2005 EDGE RADIO c p ALLSTAR CORP P4 24V...

Page 23: ...1P RED AU BLUE T J H WHITE 4 8 BALDOR YELLOW 5 1 2 3 BRAKE BL BLK BL BLK CDOMCB 2005 EDGE RADIO c p ALLSTAR CORP P4 24V S1 R58 R56 R55 R54 R45 R46 K4 K3 K5 K6 COM OLS CLS COM HIGH VOLTAGE OPEN MO4 MO...

Page 24: ...24 NOTES...

Page 25: ...r 1 2 HP 56 ODP 230 460 VAC 3 PH 005038 Motor 3 4 HP 56 ODP 230 460 VAC 3 PH Ref Part Description Parts 1 009221 Shaft Collar 1 2 008071 Flange Bearing 3 4 3 100487 Flange Bearing 1 4 105549 Snap Ring...

Page 26: ...CONTROL BOX SOLID STEEL DRIVE SHAFTS INTEGRAL MANUAL CHAIN HOIST WITH FLOOR LEVEL FULLY ADJUSTABLE INTERNAL SHAFT DRIVEN LIMITS ENGAGEMENT AND DISCONNECT ADVANCED OPERATIONAL FEATURES STANDARD P N230...

Reviews: