RISK OF ENTRAPMENT THAT MAY  

RESULT IN SERIOUS PERSONAL INJURY OR 

DEATH.  DISCONNECT POWER TO THE 

OPENER BEFORE AND DURING

  

INSTALLATION OF AN ACCESSORY  

REVERSING DOOR EDGE OR 

PHOTOELECTRIC DEVICE.   DO NOT 

RECONNECT POWER TO OPENER UNTIL

 

INSTRUCTED TO DO SO.  ENSURE DOORWAY 

IS CLEAR BEFORE STARTING TESTING OF 

UNIT.

 

 

WARNING

 

TO PREVENT THE RISK OF PERSONAL INJURY 

AND/OR DAMAGE TO DOOR OR PROPERTY, 

ONLY OPERATE DOOR CONTROL WHEN 

DOOR IS IN CLEAR VIEW.  IF CONTROL 

STATION CANNOT BE LOCATED WHERE THE 

DOOR IS VISIBLE OR IF ANY OTHER DEVICE IS 

USED TO CONTROL THE DOOR AN AUXILIARY 

ENTRAPMENT DEVICE (DOOR EDGE OR 

PHOTOELECTRIC) 

MUST BE CONNECTED

 

WARNING

 

TO  PREVENT  THE  RISK  OF  PERSONAL  INJURY 
OR DEATH : 

 DISCONNECT POWER AT THE FUSE BOX  

   BEFORE PROCEEDING. 

 ELECTRICAL CONNECTIONS MUST BE MADE 

     BY A QUALIFIED INDIVIDUAL. 

 OBSERVE LOCAL ELECTRICAL CODES WHEN 

     WIRING THE OPERATOR. 

 

WARNING

 

WARNING: The J-S and H-S Series operators have 
been designed and constructed for use with voltages 
from 115 Volts AC to 480 Volts AC, in single or three 
phase. Check the operator nameplate label on the 
control box cover for the proper voltage and phase. The 
application of an improper input voltage or phase will 
result in catastrophic failure to the internal electrical 
components.

 

 

Observe local electrical codes when wiring the operator.

 

 
When hard wiring, observe state and local electrical codes. A 
wiring diagram is attached to the inside of the control box cover. 
Connect the appropriate voltage and phase power leads to the 
appropriate terminals as per the wiring diagram and connect a 
ground wire to the grounding screw.  On three phase units, 
incorrect phasing of the power supply will cause the motor to 
rotate in the wrong direction (open when CLOSE button is pushed 
and vice versa).  To correct this, interchange any two of the 
incoming three phase conductors. 
 
The wiring diagram attached inside the cover of the control box 
details all of the field wiring terminal connections for the operator.  
Always connect the wires to the push-button controls and auxiliary 
devices exactly as shown. 
 
Warning:  Control voltage of the opener is 5 volts DC, Class 2.  
Do not run the power leads and control circuit wiring in the same 
electrical conduit. 

Note:  J-S and H-S Series model operators are pre-wired for 
entrapment protection devices. To operate in Momentary 
Contact To Close mode and comply with the UL325 
Entrapment Protection  requirements effective Aug. 29, 2010, 
an approved external entrapment device as described on Page 3 
must be installed and connected to the operator. Refer to Figure 

9 and the manufacturer‟s instructions to install and connect one 

of the approved door edge devices.  One or more contact 
sensors shall be located at the bottom edge of a vertically 
moving door.  Refer to the instructions on Page 12 for the 
Linear photoelectric system installation and wiring. 

 

If the external entrapment protection device is connected, the 
selector switches are set properly (Page 16) and the device 
detects an obstruction or becomes inactive, an opening door 
continues to open and a closing door stops, pauses and starts 
open. While in this mode, if a problem is detected while the 
operator is stopped, a close will require constant activation of 
the control Close button.  If an entrapment protection device as 
described above is attached and is properly working for 1 
second, it will be 

auto detected and the monitored function will 

be turned on

. Once the monitoring function is active, it will 

remain active even if the power is removed and the entrapment 
protection device is disconnected and power is restored. While 
in this mode, if a problem is detected while the operator is 
stopped, a close will require constant activation . 

 

Operators which have an operational entrapment protection 
device as described above may have one or more additional 
means of control which should be wired in accordance with the 
diagram supplied in the opener and also illustrated on Pages 20 
& 21.  To add a second three button station, refer to Figure 12. 

 

Number 22 gauge wire or heavier must be used for wiring 
the control stations and auxiliary control devices to the 
operator.  Smaller gauge wire will cause operational 
problems, especially when multiple push-button stations are 
used or during summer months.

 

INSTALLATION INSTRUCTIONS 

11 

Summary of Contents for H-S

Page 1: ...operators J S H S J H SERIES WITH SOLID STATE CONTROL CIRCUITRY JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS Serial Date...

Page 2: ...on 5 Table 1 Component Identification Listing 5 Installation Instructions 6 13 Figure 2 Operator Footprint J S H S 6 Figure 5 Release Hand Chain Wall Bracket Installation 7 Figure 6 Mounting Positions...

Page 3: ...hoto beam are provided Constant Contact To Close Standard operating mode The operator can be converted to Momentary Contact To Close when the photo beam as described above or one of the Miller Edge fa...

Page 4: ...ing carton inspect the nameplate on the cover of the operator control box to verify that it is the correct model for the intended application and that the voltage and phase are in accordance with elec...

Page 5: ...pedestrian door is available for entrance and exit to the building In addition YOU MUST install an auxiliary entrapment protection device reversing door edge or photoelectric beam device Connect an au...

Page 6: ...inch diameter bolts through the wall If it is not feasible to go through the wall then use lag bolts to fasten the operator to the mounting surface Locate the four holes within the tracings of the slo...

Page 7: ...chain is too long standard length for 16 foot high doors and below is 26 feet total length of chain shorten it to the desired length using the method described above and discard the unused portion Fa...

Page 8: ...Figure 6 100719 Right Side Mount Ceiling Mount Left Side Mount Ceiling Mount Center Mount Direct Couple Wall Mount Wall Mount 8 FIGURE 4 OPERATOR MOUNTING POSITIONS...

Page 9: ...107841 Figure 7 Dimensions Model H S Figure 7A Dimensions Model J S 108203 9 FIGURE 5 OPERATOR DIMENSIONS MODEL J S H S...

Page 10: ...ut switch closer to the center of the box will increase the point where the reversing feature cuts out to allow for irregularity in the floor etc The reverse cutout point is factory adjusted to approx...

Page 11: ...vices exactly as shown Warning Control voltage of the opener is 5 volts DC Class 2 Do not run the power leads and control circuit wiring in the same electrical conduit Note J S and H S Series model op...

Page 12: ...USE AN INTERLOCK SWITCH IF A LOCK IS REQUIRED TO RETAIN FUNCTIONALTY CAUTION Figure 8 Door Edge Device Note See the door edge manufacturer s installation instructions for the complete installation pr...

Page 13: ...n of this device will not enable the Momentary Contact to Open Mode Any Miller Edge ME MT MU and CPT family of edges must be connected to the SM 102 Edge Module Recognized by UL as per UL325 2010 on 0...

Page 14: ...y is clear Figure 11 PCB 112695 REV B TSLK OPEN C25 PB1 PB2 PB3 U5 STOP CLOSE OPEN C1 R84 R2 R3 D12 COM CLOSE STOP NO REV NC REV PHOTO MOTOR CONTROL BOARD Single 3 Button Station MOTOR CONTROL BOARD C...

Page 15: ...over adjust the force setting to compensate for a poorly working door To prevent the motor protector from tripping Do not exceed 10 door cycles per hour IMPORTANT The hardware box contains a caution l...

Page 16: ...open button will bypass mid stop Auto Close Timer N A D1 Operation Open Button Constant activation open override of closing door Close Button Constant activation door will stop when button is release...

Page 17: ...limit if the auto close timer has not been previously deactivated SETUP MODES Setup Modes Various operating characteristics can be modified via the setup modes The operator is moved to the close limi...

Page 18: ...lose Timer Setup This feature allows for a modification of the amount of time between the door reaching either the Mid Stop or the Full Open position and automatically starting in the close direction...

Page 19: ...RDWARE BINDING IN THE TRACK RUBBING AGAINST THE DOOR STOPS OR DEFECTIVE OR MISADJUSTED SPRINGS ANY SERVICE REQUIRED TO THE DOOR DOOR SPRINGS OR DOOR OPERATOR MUST BE PREFORMED BY A QUALIFIED PROFESSIO...

Page 20: ...OPERATION ADJUSTMENT INSTRUCTIONS 20...

Page 21: ...ON DO NOT STAND UNDER DOOR TO TEST REVERSING FEATURE USE A CORRUGATED BOX OR OTHER SIMILAR OBJECT If the operator is equipped with other means of control such as additional 3 button stations or radio...

Page 22: ...OR DIRECTION SWITCH INCOMING LEADS TO TERMINALS 5 AND 8 DUAL VOLTAGE MOTOR 230V 1P RED AU BLUE T J H WHITE 4 8 BALDOR YELLOW 5 1 2 3 BRAKE BL BLK BL BLK CDOMCB 2005 EDGE RADIO c p ALLSTAR CORP P4 24V...

Page 23: ...1P RED AU BLUE T J H WHITE 4 8 BALDOR YELLOW 5 1 2 3 BRAKE BL BLK BL BLK CDOMCB 2005 EDGE RADIO c p ALLSTAR CORP P4 24V S1 R58 R56 R55 R54 R45 R46 K4 K3 K5 K6 COM OLS CLS COM HIGH VOLTAGE OPEN MO4 MO...

Page 24: ...24 NOTES...

Page 25: ...r 1 2 HP 56 ODP 230 460 VAC 3 PH 005038 Motor 3 4 HP 56 ODP 230 460 VAC 3 PH Ref Part Description Parts 1 009221 Shaft Collar 1 2 008071 Flange Bearing 3 4 3 100487 Flange Bearing 1 4 105549 Snap Ring...

Page 26: ...CONTROL BOX SOLID STEEL DRIVE SHAFTS INTEGRAL MANUAL CHAIN HOIST WITH FLOOR LEVEL FULLY ADJUSTABLE INTERNAL SHAFT DRIVEN LIMITS ENGAGEMENT AND DISCONNECT ADVANCED OPERATIONAL FEATURES STANDARD P N230...

Reviews: