Mullion Mounting

The reader can be mounted on a wall or any suitable fl at surface. The Mullion-mounted BluePass Reader can be installed as a new 
device, or replace an existing one. Depending on the mounting location, new mounting screws may be necessary. These instructions 
assume no previous mounting hardware exists.
To properly mount the BluePass Reader, perform the following steps:

1. Identify a suitable location for mounting with proper power 

supply.

2.  Mark location on wall for mounting screws approximately 3 

inches apart with the power supply wires in center.

3.  Drill two holes.
4.  Install wall anchors to support mounting screws.
5. Feed power cable through mounting bracket’s center 

opening.

6. Place mounting bracket on wall, aligning screw mounting 

positions with wall anchors.

7.  Insert two (2) screws.
8.  Connect Reader wires to corresponding Wiegand wiring on 

panel.

9.  Connect the power supply wires to BluePass Reader.

Note:

 Ensure power supply is not energized until all wires 

are properly connected and terminated.

10.  Feed excess cable into wall.

11. Mount BluePass Reader into upper and lower mounting 

stubs.

Once completed, the BluePass LED ring will illuminate amber. 
The administrator establishes the proper online credentials 
profi les that enables the reader to function properly. After 
the profi les are created and the initial scan is complete, the 
illumination ring will change to blue.

ADA Mounting Height Requirements

ADA has certain height and reach requirements to allow 
access for persons in wheelchairs.

•  Keypads should be mounted so that the top of the number 

touchpad is no more than 48” above the fi nished fl oor with no 
obstructions in locations where wheelchair access is available only 
from the front.

•  Keypads should be mounted so that the top of the number 

touchpad is no more than 54” above the fi nished fl oor with 
no obstructions in locations where the wheelchair has 
sideways access.

SCREW 

MOUNTING 

POSITIONS

UPPER 

MOUNTING 

STUBS

LOWER 

MOUNTING 

STUB

BluePass Reader Mullion Mounting Bracket

Summary of Contents for BluePass 2N1-BTPRX

Page 1: ...P N 10019179 X15 BluePass 2 N 1 BluePass Multi Tech Reader Manual Installation Instructions...

Page 2: ...nd protocol End users can present any combination of 125 KHz prox cards and Fobs or Bluetooth Low Energy Credentials via a supported smart device such as Android and Apple mobile devices to request ac...

Page 3: ...mend using Linear s stand alone power supplies for optimum performance Voltage Current Draw 100 200 mA typical 225 mA max peak 12 VDC in low power mode At the Reader 5 5 16 VDC 12 0 VDC is recommended...

Page 4: ...rian gate must be isolated from the unit Note Placing a unit directly on a moving door or gate will damage the reader s sensitive functionality Choose a well lit location near the controlled opening W...

Page 5: ...BluePass Reader Note Ensure power supply is not energized until all wires are properly connected and terminated 10 Feed excess cable into wall 11 Mount BluePass Reader into upper and lower mounting s...

Page 6: ...LVER BLK WHT BLU BLU BluePass Reader Wiring Diagram 6 Place mounting bracket on wall aligning screw mounting positions with wall anchors 7 Screw in two 2 screws 8 Connect Reader wires to corresponding...

Page 7: ...the reader to enter a door The allowed distance between reader and mobile device is configurable by the facility manager on a per reader basis The range can be restricted such that a user must present...

Page 8: ...the system in a multi tenant residential condominium complex The property management company wants to re use mobile credentials from departing tenants reissuing them to the new tenants moving in Is t...

Reviews: