background image

5

dc2196af

DEMO MANUAL DC2196A

Quick start proceDure

Table 1

MSP2

MSP1

MSP0

OUTPUT RANGE

RESET CODE

MANUAL SPAN

SoftSpan

0

0

0

±10V

Mid-Scale

X

0

0

1

±5V

Mid-Scale

X

0

1

0

±2.5V

Mid-Scale

X

0

1

1

0V to 10V

Zero-Scale

X

1

0

0

0V to 10V

Mid-Scale

X

1

0

1

0V to 5V

Zero-Scale

X

1

1

0

0V to 5V

Mid-Scale

X

1

1

1

0V to 5V

Zero-Scale

X

Jumpers
REF_SEL (JP1):

  Selects  internal  or  external  reference 

mode. (See data sheet description of REFCOMP pin.)

MSP0,  MSP1,  MSP2 (JP2,  JP3,  JP4):

  Manual  Span 

control.  Setting  all  jumpers  to  the 1 position (Default) 

selects SoftSpan operation, with a power-up default span 

of 0V to 5V, and reset to Zero-Scale. Other options are 

listed in Table 1.

LEDs
OVRTMP:

 Lights when 

OVRTMP

 pin asserts, indicating an 

overtemperature state. (Note that LED will light if positive 

analog supply is present and OVP is not. OVP is normally 

supplied by the controller.)

Test Points

The SPI bus is available on a row of through-hole test 

points next to J1 that may be used to monitor the bus or 

to drive the bus with an external controller.

EEGND, WP:

 For factory use only.

Summary of Contents for DC2026

Page 1: ...V to 10V 2 5V 5V and 10V AtogglefeatureallowsanyorallDACstoswitch betweentwoprogrammedcodesviaasingleSPIcommand or by the TGP input pin The versatile SPI interface can operate on any logic level betwe...

Page 2: ...he controller to the host PC s USB port and run QuikEval The DC2196A software will be downloaded and installed after which a jumper setting window will appear as shown in Figure 2 The default settings...

Page 3: ...3 dc2196af DEMO MANUAL DC2196A Figure 3 Main Control Panel Quick Start Procedure...

Page 4: ...ection to the REF pin In internal reference mode the reference voltage may be monitored at this point Placing REF_SEL jumper in the EXT position allows an external reference to be connected to this po...

Page 5: ...FCOMP pin MSP0 MSP1 MSP2 JP2 JP3 JP4 Manual Span control Setting all jumpers to the 1 position Default selects SoftSpan operation with a power up default span of 0V to 5V and reset to Zero Scale Other...

Page 6: ...JP4 HEADER 2MM SINGLE STR 3POS SULLINS NRPN031PAEN RC 7 1 J1 CONN HEADER 14POS 2MM VERT GOLD MOLEX 87831 1420 8 1 LED1 LED RED LED ROHM SML 010VT ROHM SML 010VTT86L 9 1 Q1 MOSFET N CH 60V 300MA SOT 23...

Page 7: ...T MARK T N A LTC2666IUH FAMILY DEMO CIRCUIT 2196A SIZE DATE IC NO REV SHEET OF TITLE APPROVALS PCB DES APP ENG TECHNOLOGY Fax 408 434 0507 Milpitas CA 95035 Phone 408 432 1900 1630 McCarthy Blvd LTC...

Page 8: ...DING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONS...