background image

7

MULTIPLE UNIT INSTALLATIONS

Any of the four basic operation modes (Shared Line, Dedicated Line, 
Intercom, and Ring Down) may be used with multiple RE-2s. The 
telephone line wiring is “daisy chained” (the telephone line routes 
through one unit to the next) as shown below.  Always connect the 
telephone line + to 

TIP

, and - to 

RING

.

The Telephone Bypass Module only performs the bypass function 
in the Shared Line Mode, but it will provide extra electrical surge 
protection in all modes. A surge on the 

TELCO

 terminals will be 

suppressed through the 

EARTH GROUND

 terminal. Always use 

separate AC transformers to power each RE-2.
When multiple units are connected together, 

only two units can be 

controlled by resident telephone commands

, and only 

one

 unit 

can be programmed to answer the telephone (PPN #33) for remote 
telephone commands. 

Remote programming via computer is not 

supported when using multiple RE-2s.

Command Prefi x for Multiple Units

Programming and relay control may be through the individual RE-2 
keypads or through the house telephone(s) when using the Shared 
Line or Intercom Modes. To support using the house telephone(s) 
to issue commands, each RE-2 must be programmed to a different 
“command prefi x” (PPN #72).

•  Set one unit’s command prefi x to 

 

•  Set the other unit’s command prefi x to 

 

In the case of simultaneous visitors at different units when using 
the Shared Line Mode, putting one RE-2 “on hold” to communicate 
with the second RE-2, then returning to the fi rst RE-2 is not 
recommended. Instead, fi nish all communications with the fi rst RE-2 
before servicing the second RE-2. Simultaneous visitors at multiple 
units used on a single line wired in the Ring Down Mode will cause 
a “conference call” effect between units

Figure 10. Multiple Unit Wiring

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-2

TELCO

RE-2

HOU

S

E

HOU

S

E

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

GROUND

S

TAKE

FIRST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

LAST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

FROM

TELEPHONE

COMPANY

TO

HOU

S

E

TELEPHONE

S

GROUND

S

TAKE

GROUND

S

TAKE

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-2

TELCO

RE-2

HOU

S

E

HOU

S

E

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

GROUND

S

TAKE

FIRST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

LAST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

TO

INTERCOM

TELEPHONE

S

GROUND

S

TAKE

GROUND

S

TAKE

SHARED LINE

MODE

INTERCOM

MODE

DEDICATED LINE

MODE

RING DOWN

MODE

PROGRAM THI

S

RE-2 UNIT ONLY FOR

"INTERCOM MODE"

(PPN #52)

DO NOT CONNECT

TO A LIVE TELEPHONE LINE

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-2

TELCO

RE-2

HOU

S

E

HOU

S

E

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

GROUND

S

TAKE

FIRST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

LAST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

FROM

TELEPHONE

COMPANY

OR PBX

GROUND

S

TAKE

GROUND

S

TAKE

PROGRAM ALL

RE-2 UNIT

S

 FOR

"CALL FORWARDING"

(PPN #54)

TIP

RING

TIP

RING

TIP

RING

TIP

RING

TELCO

RE-2

TELCO

RE-2

HOU

S

E

HOU

S

E

TELEPHONE

BYPASS

MODULE

EARTH

GROUND

GROUND

S

TAKE

FIRST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

LAST

RE-2

ENTRY 

SYSTEM

TELCO

RING

TIP

RING

TIP

EARTH

HOU

S

E

CA

S

E

GROUND

FROM

PBX

GROUND

S

TAKE

GROUND

S

TAKE

PROGRAM ALL

RE-2 UNIT

S

 FOR

"RING DOWN MODE"

(PPN #54)

IF DE

S

IRED, CHANGE

RE

S

IDENT RE

S

PON

S

E KEY

S

(PPN #71)

Summary of Contents for RE-2

Page 1: ...dential Telephone Entry System With Built in Wireless Receiver 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation Programming and Operation Instructions ...

Page 2: ...R PROOF TAMPER RESISTANT HOUSING SUPERHETERODYNE RADIO RECEIVER REMOTE KEYPAD SUPPORT BRIGHT WHITE LED DOWNLIGHT 2 HEAVY DUTY FORM C N O N C RELAY OUTPUTS TIMED ANTI PASSBACK KEYPAD LOCKOUT TACTILE KEY FEEL TWO DOOR SENSE INHIBIT INPUTS TWO OPEN REQUEST INPUTS ACCESS KEYSWITCH PROVISION REMOVABLE TERMINAL BLOCKS OPTIONAL COLOR CCTV CAMERA PRODUCT DESCRIPTION 1 INSTALLATION INFORMATION 2 COMPONENT ...

Page 3: ...access through the RE 2 s built in radio receiver Each transmitter can be individually suspended or re activated One facility code can be programmed to identify each block of transmitters Programming of individual non block coded transmitters is limited to 24 transmitters by entering one transmitter per block System Features Time Zones The RE 2 contains an internal clock and calendar Seven program...

Page 4: ... inside a dedicated conduit that is at least six inches away from any AC line wiring Power Supply Use the supplied 16 volt 20 VA transformer to power the RE 2 DO NOT POWER ANY OTHER EQUIPMENT FROM THE SAME TRANSFORMER use a separate power supply Keep the system power wires as short as practical to reduce the chance of noise and hum pickup For low voltage power wire runs up to 100 feet use 18 AWG T...

Page 5: ... entry system s speakerphone 1 HELP BUTTON Pressing this button causes the system to play the help message to instruct the visitor on system use 2 CALL BUTTON Pressing this button causes the system to call the residence telephones with a distinctive ring signal 3 OPTIONAL COLOR CCTV CAMERA Location for the optional Model CCM 2 color CCTV camera The camera views the keypad area 4 ANTENNA CONNECTOR ...

Page 6: ...CTRIC DOOR STRIKE MAGNETIC DOOR LOCK ACCESS DEVICE POWER SUPPLY NOTE A MAGNETIC LOCK AND DOOR STRIKE ARE BOTH SHOWN TYPICALLY ONLY ONE IS USED 16 VAC 20 VA TRANSFORMER TELCO OPEN 1 KEYPAD GND KEYPAD DAT 1 KEYPAD DAT 0 KEYPAD PWR TRANSFORMER TRANSFORMER BATTERY NEG BATTERY POS SENSE 1 COMMON KEYPAD CLK KEYPAD DVAL OPEN 2 RELAY 1 RE 2 TELEPHONE ENTRY SYSTEM SENSE 2 N O COM N C N O COM N C RELAY 2 RI...

Page 7: ... mounting location 3 Install any additional mounting material required to provide surfaces inside the wall for attaching the trim ring 4 Place the trim ring in the wall hole Check for level then attach the trim ring with screws into the side tabs 5 Drill the cabinet s four self drill mounting holes the appropriate size for the hardware 6 Attach the cabinet to the trim ring using self tapping screw...

Page 8: ...PHONE WIRING OPTIONS Shared Line This is the standard configuration The telephone line is routed through the RE 2 to the house phones Pressing the Call button on the RE 2 will cause the RE 2 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones Dedicated Line Pressing the Call button on the RE 2 will cause the RE 2 to sieze the ...

Page 9: ...cond RE 2 Simultaneous visitors at multiple units used on a single line wired in the Ring Down Mode will cause a conference call effect between units Figure 10 Multiple Unit Wiring TIP RING TIP RING TIP RING TIP RING TELCO RE 2 TELCO RE 2 HOUSE HOUSE TELEPHONE BYPASS MODULE EARTH GROUND GROUND STAKE FIRST RE 2 ENTRY SYSTEM TELCO RING TIP RING TIP EARTH HOUSE CASE GROUND LAST RE 2 ENTRY SYSTEM TELC...

Page 10: ...h wiring and installation 6 To use the door sense feature to detect forced entry or door ajar conditions install a normally closed door switch on the door or pedestrian gate and route two wires from the switch to the RE 2 Connect the door sense switch to the RE 2 SENSE 1 and COMMON terminals See programming PPN 24 27 to define when Relay 2 will activate based on the sense input Figure 12 Gate Inst...

Page 11: ...phone Bypass Module EARTH GROUND terminal to the earth ground wire 3 Connect the RE 2 EARTH terminal to one of the case ground studs this connection is mandatory for lightning protection Case Ground A ground wire connects the front and rear cases together Be sure to re connect this wire before completing the installation Refer to Figure 15 for case ground wire attachment details OPTIONAL REMOTE AN...

Page 12: ...nted as shown see Figure 21 Secure the keyswitch with the large switch nut 3 Plug the two keyswitch snap on wire leads supplied with the switch onto the keyswitch COM and N O pins see Figure 22 4 Connect one keyswitch wire to the RE 2 OPEN 1 terminal Connect the other keyswitch wire to the RE 2 COMMON terminal see Figure 23 SET SWITCH TO NUMBER 3 Figure 18 Setting the Keypad Device Address OPEN 1 ...

Page 13: ...hole in the camera bracket towards the edge of the RE 2 case Secure the camera with the two retaining brackets and screws see Figure 25 5 Replace the RE 2 circuit board Secure the board with the six screws 6 Connect the camera s 4 conductor cable to the RE 2 s CAMERA connector see Figure 26 7 Connect the video cable to the RE 2 s VIDEO OUT connector see Figure 26 8 Connect the other end of the vid...

Page 14: ...to the desktop for easy future access 4 Enter the RE 2 s programming master password 123456 unless changed into the Password area Select Save Password if you want the computer to retain the password 5 Select Connect and wait for the modem to connect to the RE 2 6 Switch to the browser software and enter into the address line http 192 168 20 10 re1 html save this address as a favorite or bookmark s...

Page 15: ...ENTER 192 168 20 11 THEN CLICK ADVANCED 14 UN CHECK USE DEFAULT GATEWAY ON REMOTE NETWORK AND UN CHECK USE IP HEADER COMPRESSION THEN CLICK OK SETTING UP A WINDOWS XP DIAL UP NETWORK CONNECTION BE SURE ONLY THESE FIRST TWO BOXES ARE CHECKED 5 NEW CONNECTION WIZARD INTERNET CONNECTION SELECT CONNECT USING DIAL UP MODEM 6 NEW CONNECTION WIZARD CONNECTION NAME ENTER RE 2 LOCAL FOR A LOCAL CONNECTION ...

Page 16: ...te Telephone Connection 1 Dial the telephone number of the line that the RE 2 is connected to 2 Let the telephone ring twice and hang up 3 After 10 seconds but before 30 seconds call back to the same telephone number 4 The RE 2 will answer and sound a tone for 2 seconds 5 The RE 2 will wait for approximately six seconds for the caller to enter the Master Programming Code 6 Enter password 123456 un...

Page 17: ...7 ERASING ALL ENTRY CODES PPN 97 PAGE 16 CHANGING THE MASTER CODE PPN 98 PAGE 16 RESET SYSTEM DEFAULTS PPN 200 PAGE 18 FACTORY DEFAULTS PPN 1 ENTRY CODE LENGTH 4 DIGITS PPN 8 TRANSMITTER LEFT OR TOP LEFT BUTTON ACTIVATES RELAY 1 TRANSMITTER RIGHT OR TOP RIGHT BUTTON ACTIVATES RELAY 2 TRANSMITTER TOP BUTTON ACTIVATES RELAYS 1 AND 2 TRANSMITTER LOWER LEFT BUTTON ACTIVATES NONE TRANSMITTER LOWER RIGH...

Page 18: ...s the number of digits for all the entry codes programmed Press Length Length 2 6 for entry code length NOTE If the Entry Code Length is going to be changed from the factory default of four digits make this change first before programming any entry codes Adding a New Entry Code Use this PPN to add up to 100 entry codes Press Code Code Relay Time Zone Code The new entry code 1 999999 depending on c...

Page 19: ...st ten seconds of time allowed Press Limit Limit 15 255 Seconds allowed Call Waiting Feature On Off Default On Turns the call waiting feature on or off If call waiting is on factory default and the resident is on the telephone at the same time a visitor calls the RE 2 will generate beeps on the resident s telephone line to signal that a visitor is calling The resident has the option to switch to t...

Page 20: ...mming and Command Prefixes Defaults Programming Command The resident command prefix is entered on a local telephone prior to entering a command number to control one of the relays or open voice communications with the RE 2 The resident programming prefix is entered on a local telephone or the main keypad prior to programming the RE 2 Press Programming Command Programming 0 1 2 3 Command 0 1 2 3 AD...

Page 21: ... the modem will answer the telephone if two consecutive telephone calls occur within 30 seconds The Modem Ring Detect can be disabled this will also disable any computer based programming of the RE 2 Press Detect Detect 0 Ring detect OFF 1 Ring detect ON Keypad Beeps On Off Default On The default setting causes the main keypad to beep when each key is pressed The beeps can be disabled Press Keypad...

Page 22: ... CALL button to call the residence 2 Have the resident talk at a normal volume level while adjusting the SPEAKERPHONE VOLUME control Adjusting the control clockwise increases the volume counterclockwise decreases the volume Digital Speech Volume The DIGITAL SPEECH VOLUME adjustment controls the audio level of the voice synthesizer This adjustment effects the audio level of the voice synthesizer fr...

Page 23: ...g feature is enabled the system will forward the visitor s call to an outside telephone number during the programmed time for call forwarding The resident can control access from the forwarded telephone number The system can be programmed to produce a Do Not Disturb message for the visitor during times when privacy is desired No call will be generated to the residence and access will be denied Pre...

Page 24: ...Facility ID Action Facility Facility code 1 16 of transmitter 0 no facility code ID 5 digit ID number of transmitter Action 0 Suspend transmitter 1 Re activate transmitter Maximum Number of Visitor Rings Press Rings Rings 1 15 Rings maximum Visitor Talk Time Limit Press Limit Limit 15 255 Seconds allowed Call Waiting Feature On Off Press Call Waiting Call Waiting 1 ON 2 OFF Call Forwarding Press F...

Page 25: ...ct line ring and tip to house ring and tip Check line for buzz with test set 2 Disconnect 16 VAC wires from terminal strip if buzz goes away one side of the transformer wires is grounded 3 Check all connections for any shorts to ground Telephones in residence will not ring 1 Verify that the Do Not Disturb feature is not on while testing 2 Verify that the Call Forwarding feature is not forwarding t...

Page 26: ...H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O ...

Page 27: ... 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __ 2 __ 1 __...

Page 28: ... power and therefore limited range A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code settings Changes or modifications to the device may void FCC compliance Infrequently used radio links should be tested regularly to protect against undetected interference or fault A gener...