CONFIGURE ACCESS OUT
AREA 26
26.1
26.2
26.3
26.4
Access Out Mode
Validation Pass-TXID Pass-SEQID
Access Out Facility Code
Facility Code: 00000
Access Out Button Offset
Off On
Access Out Format
Off Wiegand26 Sentex30 SecuraKey31
FACILITY/SITE CODES
AREA 23
23.1
23.2
23.3
System Site Code
Site Code: 00000
Txmtr Facility Code
Fac Code: 000
Card Facility Code 1
Fac Code [1]: 000
Card Facility Code 2
Fac Code [2]: 000
Card Facility Code 3
Fac Code [3]: 000
Card Facility Code 4
Fac Code [4]: 000
23.4
23.5
23.6
AREA 30
SYSTEM REPORTS/UTILITIES
30.1
30.2
30.3
30.4
30.5
30.6
30.7
30.8
Print System Report
Yes No
Print Single Xmtr Report
Yes No
Print Block Xmtr Report
Yes No
Print Entry Code Report
Yes No
Print Block Card Report
Yes No
Print Tele/Entry Report
Yes No
EvntLog Rpt Start Date
00/00/1990
Print Event Log Report
All SinceLastRpt FromDate
MEMORY MODULE UTILITIES
AREA 29
29.1
29.2
29.3
29.4
29.5
Send Memory Module
Yes No
Receive Memory Module
Yes No
Copy Memory Module
Off SendMM ReceiveMM
Print Memory Module
Yes No
Initialize Memory Module
Are You Sure? Yes No
RS-232 PORT SETUP
AREA 24
24.1
24.2
24.3
24.4
RS-232 Port Device
Off Printer Modem Terminal PC
Modem Init. String 2
ATH0&FS0=0E0&N6&H0Y1&W1
Modem Termination String
ATH0
Modem Init. String 1
ATH0&F0F8E0&K0&Q0&D0&W0
RELAY SETUP
AREA 21
21.1
21.2
21.3
21.4
21.5
21.6
Which Relay to Program.
CH-A CH-B CH-C CH-D
Select Operation:
Control Shunt Alarm Obstacle CCTV
Select Timing Mode:
Time Pulse Toggle Latch
Enter Activation Time:
Time in seconds: 00000
21.7
21.8
Assign Time Zone [1]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
21.9
21.10
21.11
Enter Channel Name
Assign Telephone Digit
None 1 2 3 4 5 6 7 8 9
Channel Control
Normal Activate LockOpen LockClosed
Assign Time Zone [2]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [3]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Assign Time Zone [4]:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SYSTEM SETUP
AREA 22
22.1
22.2
Installation Name
AM/II Name
22.3
22.4
22.5
22.6
22.7
22.8
22.9
22.10
Retained Event Log
None 500 1000 2000 5000 Max
Antipassback Time
None 1min 2min 3min 4min
Integral Radio Direction
None In Out Neutral
Network Address
0ff 1 2 3 4 5 6 7 8
Keypad Strikes and Out
Strikes Allowed: 0
Door Ajar Time
Open Time Seconds: 000
Local Program Password
Password: 123456
Remote Program Password
Password: 123456
Priority Access Password
Password: 123456
22.11
CONFIGURE REMOTE DEVICES
AREA 25
25.1
25.2
25.3
25.4
25.5
25.6
Which Remote Device
DV1 DV2 DV3 DV4 DV5 DV6 DV7
Assign Control Channel
CH-A CH-B CH-C CH-D Buttons
Access Direction
None In Out Neutral
Enable Options ABCD
0=No, 1=Yes: 1111
Enter Name for Device
Type of Device
None Keypad CardRdr Radio Relay Phone SecuraKey31
TIME AND CALENDAR
AREA 20
20.1
20.2
20.3
Enter Date as mm/dd/yyyy
05/26/1995
Select Daylight Savings
Yes No
20.4
Downlight On/Off time.
On/Off: 00:00/00:00
20.5
20.6
Which Holiday [1-24]
Holiday Number: 00
Holiday Number[]: Date
Hol[01] Month/Day 00/00
STANDARD time hh:mm
13:33
20.7
Which Ex Holiday [1-24]
Holiday Number 00
20.8
Expiring Holiday XX
MM/DD/YYYY 00/00/0000
TELEPHONE ENTRY SETUP
AREA 27
27.1
27.2
27.3
27.4
27.6
Directory Code Length
1 2 3 4
Directory Begins At
Beginning(A) Middle(M)
PBX Dialing Digit
Off 9 8 7 6 5 4 3 2 1 0
27.7
27.8
27.9
27.10
Sort Directory Names Now
Yes No
Edit Display Messages
Message Number: 00
Set Talk Time
Talk Time Seconds: 060
Edit Display Message
Max Directory Entries
Maximum Entries: 00000
Delete All Tlph. Entries
Yes No
27.5
27.11
Assign Postal Key Door
CH-A CH-B CH-C CH-D Buttons
Adjust Hybrid Level
Press OK To Start/Stop
27.12
Display Brightness
Dim Low Med High
27.13
Priority Access ABCD
0=No 1=Yes 0000
39