background image

1

COMPONENT LOCATIONS

WIRING DIAGRAM

228037 A     IMAGE 3

1

2 3

4 5 6

7 8 9

0

RED/GREEN
POWER/ACCE

SS

INDICATOR

YELLOW
"LOCKOUT"
INDICATOR

KEYPAD

MA

S

TER CODE

RE

S

ET JUMPER

(P5)

TERMINAL
BLOCK #1
(TB1)

BEEPER
LEVEL
JUMPER (P4)

MOUNTING
PLATE

1 - AC OR DC

2 - AC OR DC

3

 - N.O.

4 - COM

5 - N.C.

6 - N.O.

7 - COM

8

 - N.C.

S

EN

S

E - 

8

GROUND - 7

REQUE

S

T-TO-EXIT - 6

GROUND - 5

GROUND - 4

OUTPUT #

3

 - 

3

OUTPUT #4 - 2

GROUND - 1

12-24 VOLT

AC OR DC

POWER

MAIN RELAY

5 AMP

S

 @

28 VDC MAX.

AUXILIARY

RELAY 1 AMP

@ 28 VDC MAX.

TERMINAL

BLOCK 1

WIRE

S

AK-31 TERMINALS

CAUTION

IF THE UNIT IS AC POWERED,

MAKE SURE THE SECONDARY OF THE

SYSTEM TRANSFORMER IS ISOLATED

FROM EARTH GROUND

OPTIONAL WIRING

REQUIRED WIRING

OTHER WIRING

NOTE

S

1. ALARM 

S

HUNT 

S

ET FOR AUXILIARY RELAY

2. GRAY WIRE 

S

ET FOR DOOR 

S

EN

S

E

GROUND

STAKE

N.C. DOOR

SWITCH

ALARM

CONTACT

TO ALARM

S

Y

S

TEM

POWER
SUPPLY

ELECTRIC

DOOR

STRIKE

AUXILIARY

OUTPUT

S

100 mA MAX.
TO COMMON

REQUEST

TO EXIT

BUTTON

GRAY

BLACK

VIOLET

BLACK

BLACK

BLUE

GREEN

BLACK

TYPICAL DOOR INSTALLATION WIRING

Figure 1. Component Locations

Figure 2. Wiring Diagram

Summary of Contents for AK-31

Page 1: ...1 2 3 4 5 6 7 8 9 0 AK 31 Digital Keyless Entry System 760 438 7000 USA Canada 800 421 1587 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com Installation and Programming Instructions ...

Page 2: ...s and programming even without power An internal jumper is provided to reset the master code The Main Relay has a 5 Amp capacity The Auxiliary Relay has a 1 Amp capacity Two solid state outputs capable of switching 100 mA to common are programmable to signal forced entry door ajar lockout alarm circuit shunting request to exit and keypad active conditions FEATURES KEYPAD PROGRAMMABLE No programmer...

Page 3: ...DC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 1 WIRES AK 31 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF THE SYSTEM TRANSFORMER IS ISOLATED FROM EARTH GROUND OPTIONAL WIRING REQUIRED WIRING OTHER WIRING NOTES 1 ALARM SHUNT SET FOR AUXILIARY RELAY 2 GRAY WIRE SET FOR DOOR SENSE GROUND STAKE N C DOOR SWITCH ALARM CONTACT TO ALARM SYSTEM POWER SUPPLY ELECTRIC DOOR S...

Page 4: ...in the wall Screw the mounting plate onto the electrical box see Figure 4 Final Keypad Installation After wiring the keypad see next page complete the installation by securing the keypad to the mounting plate If a lower beeper sound level is required before installing the keypad remove Jumper at P4 place the jumper block on one pin to save the jumper Hook the keypad assembly onto the mounting plat...

Page 5: ...e switch to the keypad box Connect the door switch to the keypad s SENSE input gray wire E8 and COM any black wire If an inhibit switch or timer is going to be used for temporarily disabling the keypad route two wires from the switch or timer to the keypad box Connect the inhibit switch timer normally open terminals to the keypad s SENSE input gray wire E8 and COM any black wire REQUEST TO EXIT IN...

Page 6: ... during programming to clear the keypad and re enter the command Press 9 Setting Entry Code Length Default 4 digits Press 0 3 Length Length 1 6 for entry code length NOTE If the Entry Code Length is going to be changed from the factory default of four digits make this change first before programming any entry codes Adding a New Entry Code Press 01 Code Code Action Code The new entry code 1 999999 ...

Page 7: ...o 2 seconds Press 1 4 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output to shunt alarm contacts attached to the access door This output may be timed or toggled Press 1 5 Output Output Output to Activate 0 4 1 Main Relay 2 Auxi...

Page 8: ...maximum ENVIRONMENTAL Temperature 22 F to 149 F 30 C to 65 C Humidity 5 to 95 non condensing LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty four 24 months The Warranty Expiration Date is labeled on the product This warranty extends only to wholesale customers who buy direct from Linear or through Linear s normal distribution channels...

Reviews: