background image

2

INSTALLATION

Before installing the keypad, the unit must be partially 
disassembled to access the mounting plate. The keypad’s bezel 
can be exchanged for a different color when the keypad is apart.

Opening the Keypad

The keypad assembly is secured with two tamper-resistant screws 
that are hidden behind the keypad’s faceplate. Refer to Figure 3 for 
disassembly details.

 Use a 

small

 fl at blade screwdriver to pry off the keypad’s 

faceplate.

  Use the special allen wrench (supplied) to remove the two 

tamper-resistant screws.

  Separate the mounting plate from the keypad assembly.

Changing the Keypad’s Bezel 

The colored keypad bezels snap onto the keypad assembly. Refer 
to Figure 4 for details on changing the bezel.

  Gently pull on the edge of the bezel to release the tabs that 

hold the bezel to the keypad assembly.

  Remove the bezel from the keypad assembly.

  Choose the proper color bezel for the installation and snap 

it onto the keypad assembly.

Install the Electrical Box and Mounting Plate

The keypad is designed to fi t into a standard single-gang electrical 
box. Select a location near the controlled door and choose a 
convenient height for the keypad. Be sure there is good wiring 
accessibility for the unit’s power and the output to the door strike 
or access device.

  Install the electrical box in the wall.

  Screw the mounting plate onto the electrical box (see 

Figure 5).

Final Keypad Installation

After wiring the keypad 

(see next page), complete the installation 

by securing the keypad to the mounting plate.

  If a lower beeper sound level is required, before installing 

the keypad, remove Jumper JP1 (place the jumper block on 
one pin to save the jumper).

  Hook the keypad assembly onto the mounting plate tab (see 

Figure 6).

  Use the special allen wrench (supplied) to install the two 

tamper-resistant screws.

  Fit the bottom tab on the faceplate into the slot on the 

keypad then snap the top of the faceplate in.

HOOK THE KEYPAD ASSEMBLY
ONTO THE MOUNTING PLATE

1

2

3

4

INSTALL THE
TWO SCREWS

FIT THE BOTTOM TAB OF
THE FACEPLATE INTO THE
SOLT ON THE KEYPAD

SNAP THE TOP
OF THE KEYPAD
INTO PLACE

Figure 6. Connecting the Keypad to the Mounting Plate

218370 C     IMAGE 4

PRY UP ON THE
FACEPLATE HERE

1

2

3

4

REMOVE THE
FACEPLATE

REMOVE THE
TWO SCREWS

SEPARATE THE
MOUNTING PLATE
FROM THE KEYPAD

MOUNTING

PLATE

Figure 3. Opening the Keypad

KEYPAD
BEZEL

·

 

SATIN-CHROME (FACTORY INSTALLED)

·

 

WHITE 

·

 

IVORY 

·

 

BRONZE 

KEYPAD BEZEL COLORS:

THE BEZEL SNAPS
ONTO THE KEYPAD
ASSEMBLY

KEYPAD
ASSEMBLY

Figure 4. Changing the Outer Bezel

INSTALL A SINGLE-GANG
ELECTRICAL BOX AT THE
PROPER LOCATION
FOR THE KEYPAD

ATTACH THE MOUNTING
PLATE TO THE
ELECTRICAL BOX 

MAKE SURE THE
TAB IS UP

MOUNTING
PLATE

Figure 5. Installing the Mounting Plate

Summary of Contents for AK-2

Page 1: ...7 800 392 0123 Toll Free FAX 800 468 1340 www linearcorp com 218370 C IMAGE 1 PRINTER S INSTRUCTIONS INSTR INSTL AK 2 LINEAR P N 218370 C INK BLACK MATERIAL 20 LB MEAD BOND SIZE 8 500 X 11 000 SCALE 1...

Page 2: ...be obtained from the access device or a separate power supply The EEPROM memory retains all entry codes and programming even without power An internal jumper is provided to reset the master code The...

Page 3: ...1 12 24 VOLT AC OR DC POWER MAIN RELAY 5 AMPS 28 VDC MAX AUXILIARY RELAY 1 AMP 28 VDC MAX TERMINAL BLOCK 2 TERMINAL BLOCK 1 AK 2 TERMINALS CAUTION IF THE UNIT IS AC POWERED MAKE SURE THE SECONDARY OF...

Page 4: ...e or access device Install the electrical box in the wall Screw the mounting plate onto the electrical box see Figure 5 Final Keypad Installation After wiring the keypad see next page complete the ins...

Page 5: ...route two wires from the switch to the keypad box Connect the door switch to the keypad s SENSE terminal TB1 8 and COM terminal TB1 7 If an inhibit switch or timer is going to be used for temporarily...

Page 6: ...1 Code Code Relay Code The new entry code 1 999999 depending on code length Relay Relay output entry code will activate 1 Main Relay 2 Auxiliary Relay 3 Both Relays The yellow indicator will flash qui...

Page 7: ...ts which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxili...

Page 8: ...C Current 30 mA typical 150 mA maximum Outputs Main Relay Form C 5 Amps 28 Volts maximum Auxiliary Relay Form C 1 Amp 28 Volts maximum Solid state outputs Outputs 3 4 Short to common 100 mA 24 VDC max...