- 5 -
1. As the BIOS boots, press CTRL+S or F4 to enter the raid bios utility.
2. Select
Create RAID set
. Press
F2
.
3. Select
Mirrored-Striped set
then press
F3
.
4. Select
Auto config
. Press
A
.
5. Press
Y
and then press ESC to exit the setup.
6. Continue with conventional Fdisk and Format steps as if you are installing a
conventional hard drive.
7.Your RAID configuration is complete. Please proceed to software installation
section.
3.4. Deleting RAID Sets
1. As the BIOS boots, Press CTRL+S or F4 to enter the raid bios utility.
2. Select
Delete RAID set.
Press
Enter
.
3. Answer
Y
to remove the RAID set. If the RAID set being deleted is a Striped set,
then all of the data will be lost. If the set being deleted is a Mirrored set, then the
data will remain intact and accessible on both drives.
3.5. Rebuilding Mirrored Sets
1. After replacing the failed hard drives boot the BIOS, Press CTRL+S or F4 to
enter the raid bios utility.
2. Select
rebuilding Mirrored set.
Press
Enter
.
3. Select
Online rebuild
or
Offline rebuild
.
4. Answer
Y
to rebuild the Mirrored set of hard drive.
3.5. Resolving Conflict
When a RAID set is created, the metadata written to the disk includes drive
connection information (Primary and Secondary). If, after a disk failure, the
replacement disk was previously part of a RAID set (or used in another system), it
may have conflicting metadata, specifically in reference to the drive
connection information. If so, this will prohibit the RAID set from being
either created or rebuilt, In order for the RAID set to function properly, this old
metadata must be first overwritten with the new metadata. To resolve this,
select
Resolve Conflicts
, and the correct metadata, including the correct drive
connection information, will be written to the replacement disk.
4. Software Installation