background image

User Manual 

 

English 

 

Number 

Name 

Function Description 

HDCP LED 

HDCP status indicator. 
 
▪ OFF: HDMI input is not carrying HDCP content. 
▪ ON: HDMI input is carrying HDCP content. 

LINK LED 

HDBaseT Link status indicator. 
 
▪ OFF: No Link. 
▪ GREEN: Link successful. 
▪ Blink GREEN: Link abnormal. 

VGA LED 

VGA signal indicator. 
 
▪ OFF: There is no +5V HPD or VGA signal detected on the input. 
▪ FLASHING: +5V HPD or VGA signal is detected. 
▪ GREEN: VGA input is active and the VGA signal is detected. 

POWER LED 

System power indicator. 

VGA IN 

Connect to a VGA source. 

AUDIO IN 

Connect to an external audio source for the VGA signal. 

HDMI 1 LED 

HDMI 1 signal indicator. 
 
▪ OFF: There is no +5V HPD or HDMI signal detected on the 
input. 
▪ FLASHING: +5V HPD or HDMI signal is detected. 
▪ GREEN: HDMI input is active and the HDMI signal is detected. 

HDMI 1 IN 

Connect to an HDMI source device. 

SOURCE 

Press to switch between sources. 

10 

TO PC 

Connect to the USB Host device, typically a PC 

11 

HDMI 2 LED 

HDMI 2 signal indicator. 
 
▪ OFF: There is no +5V HPD or HDMI signal detected on the 
input. 
▪ FLASHING: +5V HPD or HDMI signal is detected. 
▪ GREEN: HDMI input is active and the HDMI signal is detected. 

12 

HDMI 2 IN 

Connect to an HDMI source device. 

13 

HDBaseT OUT 

Connect to the HDBaseT Receiver with a Cat5e/6/7 cable. 

Summary of Contents for 38288

Page 1: ... LINDY Group FIRST EDITION April 2020 HDBaseT Presentation System with Control Keypad User Manual English No 38288 lindy com Tested to comply with FCC Standards For Home and Office Use ...

Page 2: ......

Page 3: ...en den HDBaseT Anschlüssen aber NIEMALS eine Netzwerkverbindung oder Ethernet oder irgendwelche aktiven Komponenten ATTENTION N utilisez qu une connexion par câble Ethernet directe entre les ports sans passer par le réseau Ethernet un commutateur ou un quelconque périphérique connecté à votre réseau IMPORTANTE UTILIZZATE UN CAVO DEDICATO PER LA CONNESSIONE TRA LE DUE UNITA NON COLLEGATELO AD UNA R...

Page 4: ... New Zealand type Use the appropriate AC adapter as shown in the picture and ensure it is firmly secured in place and does not detach by pulling before installing into a power socket To reduce risk of fire electric shocks or damage Do not open the product nor its power supply There are no user serviceable parts inside Only qualified servicing personnel may carry out any repairs or maintenance Neve...

Page 5: ... Plate HDBaseT Receiver Control Panel 24V 3 75A Multi Country DC power Supply Barrel Size 5 5 2 1mm Quick Instruction Guide Features Valens HDBaseT VS210 Chipset Distance 4K 30Hz RGB 8bit with 40m of Cat 6 cable 1920x1080 60Hz RGB 8Bit with 70m of Cat 6 cable HDMI 1 4b HDCP 2 2 and HDCP 1 4 compliant Up to 7 1 channels of High Definition audio pass through LPCM Dolby TrueHD and DTS HD Master Audio...

Page 6: ...imensions 115 9mm W x 38 7mm D x 114 3mm H Receiver Input ports 1x HDBaseT 1x Mic 1x LAN RJ45 1x USB Type A Female Output ports 1x HDMI 1x RS 232 Screw Terminal 1x Relay Screw Terminal 1x Audio Out Screw Terminal 1x 2x30 Watts 4 ohms amplifier output Screw Terminal Dimensions 250mm W x 104mm D x 30mm H Control Plate Input Output port 1x RJ45 for RS232 Power Dimensions 70mm W x 32mm D x 115mm H Ins...

Page 7: ...rce 6 AUDIO IN Connect to an external audio source for the VGA signal 7 HDMI 1 LED HDMI 1 signal indicator OFF There is no 5V HPD or HDMI signal detected on the input FLASHING 5V HPD or HDMI signal is detected GREEN HDMI input is active and the HDMI signal is detected 8 HDMI 1 IN Connect to an HDMI source device 9 SOURCE Press to switch between sources 10 TO PC Connect to the USB Host device typic...

Page 8: ...irmware updates 17 DIP SWITCH Used in combination with firmware updates Please leave on the default position Receiver Number Name Function Description 1 MIC GAIN Adjust the MIC input gain Volume 2 POWER LED System power indicator 3 LINK LED HDBaseT Link status indicator OFF No Link GREEN Link successful Blink GREEN Link abnormal 4 HDCP LED HDCP status indicator OFF HDMI input is not carrying HDCP ...

Page 9: ...or USB sink device as required 11 RS 232 RS 232 control for the display 12 RELAY To control the projector screen rise and fall 13 AUDIO OUT Connect to a speaker 14 MIC LINE SWITCH When the switch is set to MIC the microphone input is used to connect a dynamic microphone When the switch is set to LINE the microphone input is used for connecting a line level audio source or wireless microphone outpu...

Page 10: ...further details 3 DISPLAY OFF Runs the DISPLAY OFF routine please see the full manual for further details 4 HDMI 1 Selects HDMI 1 as the active source 5 HDMI 2 Selects HDMI 2 as the active source 6 VGA Selects VGA as the active source 7 SYSTEM Long press the button for 3 seconds to turn on or off the system please see the full manual for further details 8 RJ45 POWER Connect to the transmitter usin...

Page 11: ...ss is 192 168 2 100 Please make sure the device you are connecting with is on the same IP range as the unit Once the IP is entered in the web browser you should be prompted with a login page the default username and password is the same please enter admin for both The login page should look like below Main Page ...

Page 12: ...e slider will increase or decrease volume for the amplifier and the audio extractor Mute toggle will silence the amplifier and the audio extractor outputs however it does not silence the audio on the HDMI output System runs the system on off subroutine when you switch the toggle see Routines at the end of the manual Connection Status indicates the connection status about the web server Display Run...

Page 13: ...e end of the manual Auto System When the toggle is in the enable position the system will turn off when no signals are actively connected the amount of time can be configured please see the No Activity Timeout in the INPUT CONTROL section Relay Sync Sets the relays to either be triggered with the display subroutine on off or the system subroutine on off see Routines at the end of the manual ...

Page 14: ...isplay On subroutine is called RS232 Off Command Sends the string when the Display Off subroutine is called CR LF Appends a carriage return and line feed character to the end of the input strings as they are sent out Hex The commands can be input as hexadecimal numbers when the Hex checkbox is marked Save After any settings have been changed the settings must be saved by pressing the Save button ...

Page 15: ...ode and Manual mode Sets the priority to use when the switch mode is set to priority mode 1 is the highest priority and 3 is the lowest No Activity Timeout Sets the amount of time it will take for the system to turn itself off when there is no detected input signal Audio Delay Sets how many seconds the audio on the amp output is delayed ...

Page 16: ...e one stored in the systems internal memory When set on external it will use the EDID from the attached sink device EDID The name of the current EDID EDID Update Upload a bin file to change what EDID is stored in the systems internal memory that is used when EDID is set to internal System Page ...

Page 17: ... of the web interface The user and the admin password settings Please note each one is unique to the different accounts Upload new firmware and see the current version installed This can update the firmware of the control panel and the receiver box not the transmitter To update the firmware of the transmitter use the USB port on the plate ...

Page 18: ...erform a system reset hold the transmitter source button SOURCE button for 20 seconds until the HDCP light flashes three times When the system is reset user settings will return to their default values this includes passwords room label switching mode IP address etc System ON OFF Display ON OFF Routine ...

Page 19: ...eway GATE ipa CR ipa IP Adress Set the Gateway to 192 168 1 1 GATE 192 168 1 1 CR Gateway 192 168 1 1 Quary Gateway GATE CR Request the Gateway GATE CR Gateway 192 168 1 1 Input Output and switching Controls Switching Inputs to Output SW i CR i Input Switch to VGA and Audio SW V CR VGA Active V VGA Audio DP DisplayPort Switch to DisplayPort SW DP CR DP Active H or H1 H2 HDMI Switch to HDMI1 SW H1 ...

Page 20: ...nmute the Audio Output AM 0 CR Audio Output Mute Off 0 Unmute Audio Output 1 Mute Audio Output Mute the Audio Output AM 1 CR Audio Output Mute On T Toggle Toggle the Mute AM T CR Audio Output Mute Off On Query Mute Status AM CR Request Audeo Mute Status AM CR Audio Output Mute On Off Auto RS232 Command Features Input Detect Command Set IDC a h t CR send command 60 seconds after input on switch is ...

Page 21: ...D CR Video Output Format Video Output Format Setting VOUT a CR a Output Format Set Output Format to HDMI VOUT H CR Output Format HDMI H HDMI D DVI Set Output Format to DVI VOUT D CR Output Format DVI A Auto Set Output Format to Auto Depend on Sink EDID VOUT A CR Output Format Auto Query Output Format VOUT CR Request the Output Video Format Setting VOUT CR value Mode Relay Relay Control RELAY1 a CR...

Page 22: ...llation You are cautioned that changes or modification not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference...

Page 23: ... übernehmen die Gerätehersteller LINDY bietet deutschen Endverbrauchern ein kostenloses Rücknahmesystem an beachten Sie bitte dass Batterien und Akkus den Produkten vor der Rückgabe an das Rücknahmesystem entnommen werden müssen und über die Sammel und Rückgabesysteme für Batterien separat entsorgt werden müssen Ausführliche Informationen zu diesen Themen finden Sie stets aktuell auf der LINDY Web...

Reviews: