background image

 

 

The EDID learning function is only necessary  whenever you have a display on the DVI  output 
port  that  cannot  play  video  correctly.  Because  DVI  sources  and  displays  are  capable  of 
outputting  various  resolutions,  the  Matrix  will  always  output  the  lowest  resolution  from  all  the 
connected devices. To correct this problem you can force the Matrix to learn the EDID from the 
lowest resolution display connected by performing the following procedure: 
 

1. 

Using the front buttons, select both the Input and output ports of the source and display 
with the lowest working resolution. 

2. 

Press  and  hold  the  +  button  of  the  output  port  and  the  –  button  of  the  input  port  for  2 
seconds. 

3. 

When  you  release  the  buttons  the  EDID  of  the display  connected will  be  written  to  the 
connected input port. 

4. 

If the procedure was successful the LED of the input ports will show a zero “ ” and if it 

was unsuccessful then it will show an F “ ”. 

 
To restore the default EDID to any specific port, perform the following procedure: 
 

1. 

Select the input you want to restore the default EDID to and match the LED on the output 
port (not input port) 

2. 

Press the + buttons on both the input and output at the same time for 2 seconds.  

3. 

When you release the buttons the default EDID will be restored to the input port. 

4. 

If the procedure was successful the LED of the input ports will show a zero “ ” and if it 

was unsuccessful then it will show an F “ ”. 

 
Dip switches 

 

Dip Switch Position 

Pin #1 

Pin#2 

Pin#3 

Pin#4 

Operation mode via RS-232 Port

1  

OFF (

)  OFF (

)  On (

OFF (

Firmware 

update 

mode

2

 

Block A Main 

On (

OFF (

)  On (

OFF (

Block B Remote  On (

On (

On (

OFF (

 
1.  Factory default setting, pins 1, 2 & 4 

set to “Off” & 3 set to “On. This is the default mode for 

RS-232 control. 

2.  Firmware update mode can only be used via RS-232 with the PC set to COM1. 

a. Power  off  your  8x8  DVI  Matrix  and  connect  your  serial  cable  to  the  RS-232  port  and 

serial port of your PC.  

b.  Execute the firmware update program on your PC via the COM 1 port. 
c.  Set Pin 1 & 3 of Blo

ck A Main to the “on” position for firmware update mode. 

d.  Set Pins 2 & 3 to the respective positions to assign which block is to be updated. 
e. Power  on  your  Matrix  and  the  firmware  update  program  should  begin  the  update 

sequence automatically. (If the program does not start, check the cable connections). 

f.  Once the firmw

are update sequence has completed, the screen will display “OK”, at this 

point turn off the Matrix. 

g.  When all updates are complete, set the dip switches to normal operation mode. 
h.  Power on the LINDY 8x8 DVI Matrix. 

 

Software Control 

 

Note:  before  inserting  the  serial  cable,  make  sure  that  the  main  dip  switches  are  set  to  the 
correct position. Incorrect dip switch settings will result in the DVI Matrix not being picked up on 
the PC com port. 

Summary of Contents for 38089

Page 1: ...LINDY ELECTRONICS LIMITED LINDY ELEKTRONIK GMBH SECOND EDITION March 2014 8x8 DVI Matrix User Manual No 38089 www lindy com Tested to Comply with FCC Standards For Home and Office Use...

Page 2: ...extension cable 1 5m Rack mount brackets IR remote control IEC mains cable User manual Driver CD Features DVI 1 0 Compatible Single Link Supports resolutions up to 1920 x 1200 WUXGA 1080p Supports and...

Page 3: ...he output outputs you would like it to display on Repeat this for multiple pictures on multiple screens The channel switching takes approximately 2 seconds Fn Source Sel 1 Escape system lock Fn Source...

Page 4: ...input port 4 If the procedure was successful the LED of the input ports will show a zero and if it was unsuccessful then it will show an F Dip switches Dip Switch Position Pin 1 Pin 2 Pin 3 Pin 4 Ope...

Page 5: ...device Rename Allows you to assign custom names to the inputs and outputs within the software Ethernet Allows you to read and write the Ethernet settings to and from the unit You must be under RS232...

Page 6: ...ose the COM port or Ethernet connection to the matrix switch Mapping Selecting the mapping option will provide an alternative method for selecting the outputs you would like to begin connecting your i...

Page 7: ...ct Input 1 A2 Output A select Input 2 E2 Output E select Input 2 A3 Output A select Input 3 E3 Output E select Input 3 A4 Output A select Input 4 E4 Output E select Input 4 A5 Output A select Input 5...

Page 8: ...lektroG in deutsches Recht umgesetzt Dieses Gesetz verbietet das Entsorgen von entsprechenden auch alten Elektro und Elektronikger ten ber die Hausm lltonne Diese Ger te m ssen den lokalen Sammelsyste...