background image

 

 

Full details of the RS-232 protocols can be found on the CD provided 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CE Certification 

This  equipment  complies  with  the  requirements  relating  to  Electromagnetic  Compatibility  Standards 
EN55022/EN55024 and the further standards cited therein. It must be used with shielded cables only. 
It has been manufactured under the scope of RoHS compliance. 

 

CE Konformitätserklärung 

Dieses  Produkt  entspricht  den  einschlägigen  EMV  Richtlinien  der  EU  für  IT-Equipment  und  darf  nur 
zusammen mit abgeschirmten Kabeln verwendet werden. 
Diese Geräte wurden unter Berücksichtigung der RoHS Vorgaben hergestellt. 
Die formelle Konformitätserklärung können wir Ihnen auf Anforderung zur Verfügung stellen 

 

FCC Certification 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation.  
You  are  cautioned  that  changes  or  modification  not  expressly  approved  by  the  party  responsible  for 
compliance could void your authority to operate the equipment. 
This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 

1. This device may not cause harmful interference, and 

2. This device must accept any interference received, including interference that may cause undesired 

operation.

 

 

COMMAND

 

ACTION

 

COMMAND

 

ACTION

 

ST

 

System Status

 

VR

 

Firmware Version

 

A1

 

Output A select Input 1

 

E1

 

Output E select Input 1

 

A2

 

Output A select Input 2

 

E2

 

Output E select Input 2

 

A3

 

Output A select Input 3

 

E3

 

Output E select Input 3

 

A4

 

Output A select Input 4

 

E4

 

Output E select Input 4

 

A5

 

Output A select Input 5

 

E5

 

Output E select Input 5

 

A6

 

Output A select Input 6

 

E6

 

Output E select Input 6

 

A7

 

Output A select Input 7

 

E7

 

Output E select Input 7

 

A8

 

Output A select Input 8

 

E8

 

Output E select Input 8

 

B1

 

Output B select Input 1

 

F1

 

Output F select Input 1

 

B2

 

Output B select Input 2

 

F2

 

Output F select Input 2

 

B3

 

Output B select Input 3

 

F3

 

Output F select Input 3

 

B4

 

Output B select Input 4

 

F4

 

Output F select Input 4

 

B5

 

Output B select Input 5

 

F5

 

Output F select Input 5

 

B6

 

Output B select Input 6

 

F6

 

Output F select Input 6

 

B7

 

Output B select Input 7

 

F7

 

Output F select Input 7

 

B8

 

Output B select Input 8

 

F8

 

Output F select Input 8

 

C1

 

Output C select Input 1

 

G1

 

Output G select Input 1

 

C2

 

Output C select Input 2

 

G2

 

Output G select Input 2

 

C3

 

Output C select Input 3

 

G3

 

Output G select Input 3

 

C4

 

Output C select Input 4

 

G4

 

Output G select Input 4

 

C5

 

Output C select Input 5

 

G5

 

Output G select Input 5

 

C6

 

Output C select Input 6

 

G6

 

Output G select Input 6

 

C7

 

Output C select Input 7

 

G7

 

Output G select Input 7

 

C8

 

Output C select Input 8

 

G8

 

Output G select Input 8

 

D1

 

Output D select Input 1

 

H1

 

Output H select Input 1

 

D2

 

Output D select Input 2

 

H2

 

Output H select Input 2

 

D3

 

Output D select Input 3

 

H3

 

Output H select Input 3

 

D4

 

Output D select Input 4

 

H4

 

Output H select Input 4

 

D5

 

Output D select Input 5

 

H5

 

Output H select Input 5

 

D6

 

Output D select Input 6

 

H6

 

Output H select Input 6

 

D7

 

Output D select Input 7

 

H7

 

Output H select Input 7

 

D8

 

Output D select Input 8

 

H8

 

Output H select Input 8

 

Summary of Contents for 38089

Page 1: ...LINDY ELECTRONICS LIMITED LINDY ELEKTRONIK GMBH SECOND EDITION March 2014 8x8 DVI Matrix User Manual No 38089 www lindy com Tested to Comply with FCC Standards For Home and Office Use...

Page 2: ...extension cable 1 5m Rack mount brackets IR remote control IEC mains cable User manual Driver CD Features DVI 1 0 Compatible Single Link Supports resolutions up to 1920 x 1200 WUXGA 1080p Supports and...

Page 3: ...he output outputs you would like it to display on Repeat this for multiple pictures on multiple screens The channel switching takes approximately 2 seconds Fn Source Sel 1 Escape system lock Fn Source...

Page 4: ...input port 4 If the procedure was successful the LED of the input ports will show a zero and if it was unsuccessful then it will show an F Dip switches Dip Switch Position Pin 1 Pin 2 Pin 3 Pin 4 Ope...

Page 5: ...device Rename Allows you to assign custom names to the inputs and outputs within the software Ethernet Allows you to read and write the Ethernet settings to and from the unit You must be under RS232...

Page 6: ...ose the COM port or Ethernet connection to the matrix switch Mapping Selecting the mapping option will provide an alternative method for selecting the outputs you would like to begin connecting your i...

Page 7: ...ct Input 1 A2 Output A select Input 2 E2 Output E select Input 2 A3 Output A select Input 3 E3 Output E select Input 3 A4 Output A select Input 4 E4 Output E select Input 4 A5 Output A select Input 5...

Page 8: ...lektroG in deutsches Recht umgesetzt Dieses Gesetz verbietet das Entsorgen von entsprechenden auch alten Elektro und Elektronikger ten ber die Hausm lltonne Diese Ger te m ssen den lokalen Sammelsyste...

Reviews: