VRI-6
VRI Operation/Installation Manual
General Safety Instructions
Product Warnings
Node Power Supply
VRI Power Supply Assembly, 1608401
A readily accessible disconnect device shall be provided for permanently connected equipment.
Disconnect all power before servicing.
The disconnect for this device is located at the irrigation systems main panel.
Over current protection shall be provided, externally, to the equipment. It shall be capable of providing no
more than 6.3 Amps of continuous current draw.
Installation of the AC main connection requires the protective earth conductor to be trimmed “longer” than
the Line and Neutral conductors.
Equipment is to be installed securely before operation.
Burn Hazard: Disconnect all power for a minimum of 15 minutes prior to servicing.
VRI Controller
VRI Panel, Main Controller Assembly, 1499570
All hazardous live (greater than 42 Vrms 60 Vdc) input and output connections must be separated from
AC mains through an approved isolation transformer, meeting the requirements for reinforced insulation
of 2660 Vac.
Powered only from an approved Class 2 power source.
This product shall only be interconnected to other Class 1 or Class 2 devices.
A disconnect device is not provided. A readily accessible disconnect device shall be incorporated exter-
nally to the equipment. The system disconnect device is at the irrigation systems main panel.
Summary of Contents for GROWSMART
Page 1: ...Variable Rate Irrigation Installation Manual P N 1600043 Rev M ECN 34095...
Page 2: ......
Page 4: ...P N 1600043 Rev M ECN 34095 VRI Installation Manual...
Page 27: ...P N 1600043 Rev M ECN 34095 13 VRI Installation Manual This page is left blank intentionally...
Page 30: ...P N 1600043 Rev M ECN 34095 16 VRI Installation Manual VRI VISION BOSS Control Panel Wiring...
Page 44: ...P N 1600043 Rev M ECN 34095 30 VRI Installation Manual...
Page 52: ...P N 1600043 Rev M ECN 34095 APDX 8 VRI Installation Manual Appendix...
Page 54: ...P N 1600043 VRI Operation Installation Manual Revisions...