P/N 1605606 Rev A (ECN 32937)
10
IM3000 Installation Manual
6. Remove the aluminum shield and the silicone gasket
underneath which hold the battery pack in place.
7. Route the signal and excitation cable harnesses
through the center of the battery pack and remove
the battery pack from the meter housing.
8. Take the new battery pack and route the signal and
excitation cable harnesses through the center of the
battery pack. Place the battery pack into the meter
housing.
9. Ensure no cable harnesses are caught between the
bottom of the battery pack and the meter housing.
10. Re-install the silicone gasket, aluminum shield and
copper standoffs.