LB-1000-FR
User Manual
Output level Cal + / -
Calibrate the RF output level for accurate measurement
Serial Number
Shows the module serial number
Hardware Version
Shows the hardware version
Firmware Version
Shows the firmware version
Temperature
Shows the current module temperature
Running Time
Shows the active run time of the module
Figure 5: LB-1000-FR settings - Page 2
5.2
LB-1000-FR settings: Using Web interface
Refer to LB-1000-CM manual. Connect your computer to the LB-1000-CM using the RJ-45 LAN
port. Login to the LB-1000-CM Web interface.
On the home screen of the LB-1000-CM Web interface, click the corresponding application module
slot (#1 - #18) where the LB-1000-FR is plugged in. The selected application module will be
highlighted and the screen will show settings for the LB-1000-FR return receiver.
User can monitor parameters and modify the configurable parameters of the LB-1000-FR module in
this interface. Press +/- buttons to modify the parameters.
If the application module parameter has an alarm it will be displayed in
red font
. If no alarm, the
parameter will be displayed in
green font
. Click the “Alarms” option on the left side of the screen to
see the Alarm list. Find alarm information for corresponding slot number and module from alarm list.