2-2035 Fisher Dr, Peterborough, ON K9J 6X6 Canada | Tel: +1.705.742.1350 or +1.800.465.7046 | Email: [email protected]
8
|
P a g e
LB-1000-FR
User Manual
5.0 LB-1000-FR SETTINGS
Once the LB-1000-FR module is successfully connected, powered up and operating normally, you
will be able to see the corresponding slot populated with the module on the screen and on the web
interface of the LB-1000-CM system management module.
5.1
LB-1000-FR settings: Using touch screen
On the home screen of the LB-1000-CM touch screen, tap/touch the corresponding application
module slot (01-18) where the LB-1000-FR is plugged in. The selected application module will be
highlighted and the screen will show settings for the LB-1000-FR return receiver.
Figure 4: LB-1000-FR settings - Page 1
If a parameter indicates an alarm it will be displayed in
red font
. No alarm, the parameter will be
displayed in
green font
.
PARAMETERS
DESCRIPTION
LB-1000-FR
Optical Input Power
Displays the Input Optical power for the channel
Gain Mode A / M
Select Automatic or Manual Gain Control mode for the receiver.
RF State
Displays the state of RF at the RF detector for switching.
EQ C / -
Set the slope for RF output. Max value: 15dB; Min value: 0dB
Output level + / -
Displays RF output level in dBmV. Can also increase or decrease the
RF output level according to requirement.