background image

 

 

 

2-2035 Fisher Dr, Peterborough, ON K9J 6X6  Canada | Tel: +1.705.742.1350 or +1.800.465.7046 | Email: [email protected]  

13 

|

 

P a g e

 

 

LB-1000-FR

 

User Manual

 

Lindsay Broadband Return Material Authorization (RMA) Form 

 

 

 

 

 

 

 

 

Company 

Contact Name: 

Address: 

City: 

Prov/State: 

Postal Code/Zip: 

Phone: #: 

Fax #: 

Email address (if applicable) 

RMA #         

(To be supplied by Lindsay Broadband)

 

Date: 
___________ 

Reason for return 
 
 
 
 
 
 
 

Qty. 

LBI Part # 

Description 

P.O. # 

P.O. 
Date 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service Repair Policy 

Lindsay Broadband product may be 
returned for repair under the following 
condition: 
1.

 

Please contact Lindsay 
Broadband Service Dept. to 
obtain an RMA#. 

2.

 

Please supply requested 
information to verify 2warranty 
coverage. 

Any shipments received by Lindsay 
Broadband without an RMA # will be 
refused

Credit Return Policy 

Lindsay Broadband products may be 
retuned for credit under the following 
conditions: 
1.

 

Products are unused and 
undamaged. 

2.

 

Products are accompanied by a 
one dollar (new purchase) for 
one dollar (credit return) order. 

3.

 

Products were purchased within 
one year from credit return date 
and are in a current catalog. 

4.

 

Products are subject to a 10% 
per RMA and $2.00 per line item. 

5.

 

Products that are custom made 
are subject to an additional 
charge for conversion of not less 
than 20% and not more than 
50% of the FFP price. 

6.

 

Product that require factory 
repacking are subject to an 
additional charge for material 
and labour.   

7.

 

Please contact Lindsay 
Broadband Customer Service to 
obtain an RMA#. 

Any shipments received by 

Lindsay Broadband without 

an RMA# will be refused. 

Note:  Products that are judged by 
Lindsay Broadband Inc. upon 
receipt as being unacceptable for 
credit shall be returned to sender 
at their expense. 

SHIPPING INSTRUCTIONS 

1.

 

Make Sure to Obtain an RMA# 
and mark a box(s) accordingly 

2.

 

Ship Only Items Authorized 

3.

 

Enclose Packing Slip & Product 
Return Authorization Form 

4.

 

Ship Prepaid Only to : 

Lindsay Broadband Inc 
2-2035 Fisher Dr. 
Peterborough, ON CANADA  
 K9J 6X6 

Attn:  Product Returns

 

Summary of Contents for LB-1000-FR

Page 1: ...Feb 03 2020 LB 1000 FR Headend Platform 1 GHz 1 2 GHz Forward Optical Receiver User Manual...

Page 2: ...F CONTENTS ii 1 0 PRODUCT OVERVIEW AND FEATURES 1 1 1 Description 1 1 2 Features 1 1 3 Specifications 2 1 4 Block diagram of the LB 1000 FR 3 2 0 SAFETY NOTES 4 3 0 APPLICATION MODULE DESCRIPTION 5 4...

Page 3: ...porates a low noise PIN detector and RF amplifier chain Internal selectable RF attenuators can be switched in or out to control RF output levels Module parameters can be monitored and configured throu...

Page 4: ...MHz 14 dB 860 1218 MHz RF Output Level 30 dBmV 4 RF Output Control Yes 5 EQ Control 15 dB 6 Optical AGC 6 to 2 dBm RF Test Point 20 1 dB 7 CTB 67 dBc 8 CSO 63 dBc 8 CNR 51 dB 8 Impedance 75 Connector...

Page 5: ...erborough ON K9J 6X6 Canada Tel 1 705 742 1350 or 1 800 465 7046 Email support lindsaybb com 3 P a g e LB 1000 FR User Manual 1 4 Block diagram of the LB 1000 FR Figure 1 Block diagram of the LB 1000...

Page 6: ...ors which connects to this LB 1000 FR exposure can cause permanent injury to eyes Avoid direct exposure to the laser light source Never stare directly into a fiber or at any mirror like surface that c...

Page 7: ...he Forward receiver module is operating normally and will be red when there is an alarm 2 The Test Point is a 20dB TP relative to the output port 3 Module Handle to draw the application module in out...

Page 8: ...ng the module in the rack Ensure that the application module is securely connected to the LB 1000 CH rear panel and F connectors The application module will be automatically power ON The Status LED on...

Page 9: ...ical jumper connectors are matched properly to the device adapters i e SC APC to SC APC Using mismatched connectors will damage the connectors and degrade system performance Ensure that each fiber has...

Page 10: ...01 18 where the LB 1000 FR is plugged in The selected application module will be highlighted and the screen will show settings for the LB 1000 FR return receiver Figure 4 LB 1000 FR settings Page 1 I...

Page 11: ...the LB 1000 CM using the RJ 45 LAN port Login to the LB 1000 CM Web interface On the home screen of the LB 1000 CM Web interface click the corresponding application module slot 1 18 where the LB 1000...

Page 12: ...2 2035 Fisher Dr Peterborough ON K9J 6X6 Canada Tel 1 705 742 1350 or 1 800 465 7046 Email support lindsaybb com 10 P a g e LB 1000 FR User Manual Figure 6 LB 1000 FR Web Interface...

Page 13: ...2 2035 Fisher Dr Peterborough ON K9J 6X6 Canada Tel 1 705 742 1350 or 1 800 465 7046 Email support lindsaybb com 11 P a g e LB 1000 FR User Manual 6 0 WARRANTY AND RMA POLICY...

Page 14: ...y appear RETURNS 1 Fill out the Product Return Authorization Form indicating product information Repair items do not require original invoice information but it is helpful to determine warranty eligib...

Page 15: ...aged 2 Products are accompanied by a one dollar new purchase for one dollar credit return order 3 Products were purchased within one year from credit return date and are in a current catalog 4 Product...

Reviews: