background image

 VCH 02237 AS-200-us Green Line 

LINDR FLOW-THROUGH 

WATER COOLING

 

ENGLISH

 

Number 010-2020 

 Valid 2020-01-01 

Summary of Contents for VCH 02237 AS-200-us

Page 1: ...VCH 02237 AS 200 us Green Line LINDR FLOW THROUGH WATER COOLING ENGLISH Number 010 2020 Valid 2020 01 01...

Page 2: ...al is an integral part of the device It must be stored in the vicinity of the device for the entirety of its service life and must be made available to the user any time the device is installed moved...

Page 3: ...ets and outlets 11 11 Thermostat placement 12 12 Temperature and adjustment 12 13 Putting into operation 13 14 Interconnecting beverage tubing 14 15 Pouring water into the tank 15 16 How to work with...

Page 4: ...Not following instructions may cause injury or damage the device WARNING Risk of injury by electrical current NOTE This symbol indicates information and recommendations for the user WARNING The cooli...

Page 5: ...gy drain Cooling transfer is done using water or glycol If the thermostat is set to max the device can accumulate a large amount of energy in the form of an ice bank The time required to accumulate th...

Page 6: ...bag suffocation hazard WARNING Cleaning and maintenance of the appliance on the part of the user must not be done by unsupervised children WARNING Before connecting to main electrical supply check tha...

Page 7: ...t use an open flame or potential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the cooler so that heat created by the cooling unit can be vented suffic...

Page 8: ...8 V Clearances mm inch Model Top Rear Right Side Left Side Front AS 110 us 200 7 87 200 7 87 508 20 70 2 76 200 7 87...

Page 9: ...regulations of the Czech Republic or in accordance with the trade agreement During the validity period of the warranty we will remove any defects on the product free of charge provided these defects...

Page 10: ...10 9 Description of the cooler 1 Thermostat 6 Pumps 2 Main switch 7 1 2 12 7 mm cool water outlet Speed fiting 3 Pump socket 8 Condenser 4 Product label 5 Power cable...

Page 11: ...11 10 Beverage inlets and outlets The pump outlet is fitted with a 1 2 12 7 mm speed fiting Pump outlet cold water Pump reverse...

Page 12: ...of the cooler 12 Temperatureand adjustment The temperature of the cooled beverage is controlled by a mechanical thermostat The thermostat has a numerical scale of 1 7 Setting the thermostat to 6 7 cre...

Page 13: ...nd connections are sufficiently tightened WARNING If you discover a leak turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed con...

Page 14: ...14 14 Interconnecting beverege tubing The figure shows a model example of connection...

Page 15: ...15 15 Pouring water into the tank WARNING Always disconnect the device from power before pouring in water 1 Remove the two screws holding the lid 2 Remote the lid...

Page 16: ...16 3 Pour water all the way up to the overflow 4 Replace the lid and secure it with screws...

Page 17: ...be straight so that it plugs fully into the coupling If the hose will not go in moisten the end of the hose Speed fiting Removal Hold the grey ring tight against the body of the speed fiting and pull...

Page 18: ...e beverage tubing of the cooler after each use with pressurised water see Sanitation by Water To make flushing easier use a sanitation adapter according to your type of keg coupler not included in sta...

Page 19: ...a week check that the device is not exposed to radiant heat 1x a week check that air circulation is not obstructed 1x a month check the cooling unit s condenser and clean it regularly 1x a year have a...

Page 20: ...20 Warning Disconnect the device from power before cleaning the condenser 1 2 3...

Page 21: ...21 4 5...

Page 22: ...setting Turn the thermostat knob to the right towards number 7 Poor air circulation Check the cleanliness of condenser plates The air vents are obstructed Free up the air vents The device overheats P...

Page 23: ...Components ALWAYS USE ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer 23 Spare parts When orderin...

Page 24: ...ower Hp 3 4 Power W 2050 Max output l hour 200 Sustained output l hour 150 Temperature difference At C 10 Coolant type R290 Voltage 115 V 60 Hz Input power W 886 Current A 7 70 Pump displacement 2x 12...

Page 25: ...25 25 Wiring diagram...

Page 26: ...26 26 Cooling diagram...