background image

5.

1.

2.

5.

6.

2.

3.

8.

8.

7.

3.

4.

4.

1. Beverage

 

 inlet

2. Keg coupler (S-type, A-type, 
M-type)

3.

 

Plastic fitting 

F 5/8 x9.5mm

4.

 

Plastic fitting 

F 5/8 x 8 mm

5.

 

Plastic  fitting 

Y  8x8x8mm

6. 

Pressure

 

 reducer

 

CO2

 

7. Plastic fitting 

F 7/16 x 8mm

8. Beverage

Connection D: using a machine with two dispensing taps together
with a CO2 bottle.

Other options of pressurizing:

By compressor PUMA 1HP a 1/2HP, compressor LEONARDO 1HP, compressor  AIRCRAFT  1HP or with N2 bottle.

1. 
2. CO2  o

utlet

 

3. Pressure Control
4. Keg coupler (S-type, A-type, 
M-type))
5. 

Plastic fitting 

F 5/8 x9.5mm

6. 

Plastic fitting 

F 5/8 x 8 mm

7. High pressure hose with a 
sleeve nut 

W 21.8 

 for the 

cylinder with thread 

G3/4

 is 

needed to use the adapter for 
K 115 / R.
8. 

Beverage

Beverage inlet

1.

2.

4.

4.

6.

6.

5.

5.

7.

8.

8.

1. Screw  the  plastic  fittings  onto  the  keg  coupler  (see picture 5 and 6 / page 9).
2. Insert  the hose 3 / 8 and 5 / 16 into the the plastic fittings on the keg coupler (see picture 8 and 9 / page 9).
3. Connect the hose 3 / 8 and 5 / 16 with the plastic fittings placed on the cooling machine according to the descrip-     
tion on the label. The label is located above the fittings.
4.  Attach the high pressure hose to the C02 bottle using a cap nut (No. 7).
5. Put the coupler on the beverage keg and make sure the coupler is in the closed position (upper position).
6. Open the shut-off valve on the CO2 bottle and set the desired pressure for both lines using the srews  on the top of 
the machine (No.3). (The pressure setting is displayed on the manometer on the front side of the cooling machine).
7. Connect the keg using the keg coupler.

ENGLISH

Connection E: CONTACT 115R for use to pressurize the traditional CO2 bottle (or mixed gas of CO2
and N2 - reduction)
(machine with two dispensing taps)

Connection and regulation of CONTACT 115 / R to CO2 bottle 

3.

Summary of Contents for PYGMY 20

Page 1: ...NS FOR USE FLOW TYPE CONTACT COOLER LINDR ENGLISH LINDR CZ s r o Cooling and dispensing systems Sadov 132 CZ 503 15 Nechanice Czech Republic Tel 495 447 239 l Fax 495 425 085 l E mail info lindr cz ww...

Page 2: ...rt tools or other objects into the propeller fan CAUTION Never touch electrical components with wet or damp hands CAUTION To ensure the performance of the cooling unit never blocktheairinlet Beer disp...

Page 3: ...k of the cooler is labelled with an AIR sign see connection A C 9 Connect the air supply ontotheplasticfitting F 5 8 x 8 mm or connect withbuilt incompressor 8 Insert the beverage tube 3 8 going from...

Page 4: ...e 4 Plastic fitting F 5 8 x9 5mm 5 Plastic fitting F 5 8 x 8 mm 6 Plastic fitting Y 8x8x8mm 7 Beverage 8 ON OFF switch for the compressor Connection C Using a built in compressor to pressurize for mac...

Page 5: ...6 6 5 5 7 8 8 1 Screw the plastic fittings onto the keg coupler seepicture5and6 page9 2 Insert thehose3 8and5 16intothetheplasticfittingsonthekegcoupler seepicture8and9 page9 3 Connect the hose 3 8 an...

Page 6: ...e Disconnection THE TUBE MUST NOT BE UNDER PRESSURE WHEN DISCONNECTING the gray ring 6 Environment protection Wastesorting This product must not be disposed of with any household waste Packaging allow...

Page 7: ...nitizing using a sanitizing bottle Unscrew the head from the sanitizing bottle and pour clean water inside Screw the head onto the sanitizing keg then connect the keg coupler and pressurize the samewa...

Page 8: ...of the condenser isn t blocked Put the machine in colder surroundings The beverage shoots out under high pressure The pressure is too high Lower the pressure in the keg The air compressor doesn t swit...

Page 9: ...YES 14 5 kg 16 4kg 35l h 19 7kg 1 55A 357W 50l h 50l h 90l h 40l h 40l h 70l h 26 8kg 29 3 kg 1 83A 2 18A 421W 501W YES 30 0kg 2 18A 501W 34 0kg 36 0kg 2 90A 3 20A 667W 735W KONTAKT 115 KONTAKT 115 K...