8.
Problem
Cause
How to f
ix it
Beverage doesn't flow
The keg is connected
wrongly
Not enough air pressure
(low pressure)
The water froze after
sanitation
Closed compensator
Check if the keg coupler is connected properly
Use a pump - pump air into the keg
CO2-check the pressure in the machine with inbuilt
compressor- turn on the switch
Switch off the machine and you have to wait until
beverage will start flowing again (it can takes a few
minutes or up to several hours)!
Move with the small lever on the compensator
Beverage isn't cooled
enough
Setting of thermostat is
not correct
Bad air circulation
The machine is
overheated
Turn the thermostat to number 7
Check if the plate of the condenser isn´t blocked
Put the machine in colder surroundings
The beverage
shoots out
under high pressure
The pressure is too high
Lower the pressure in the keg
The air compressor
doesn't switch on
Switch the button on the cooler
Turn the adjustment screw to the right
(
Kprofi
models
).
Air compressor doesn't
switch off
Loose connections
Pull out the air tube and then insert again
Tighten the nuts on the keg coupler
With Kprofi models check the pressure on the
manometer
Excessive beer foaming
Lower the beverage temperature, turn the thermostat
to the right
Compensate the beverage flow capacity, move the
little lever of the compensator upwards
Fittings do not seal
properly
The tube is not inserted
correctly
Damage to the tube
Pull out the tube, check for any sharp edges,
and if there are, cut with knife
Pull out the tube and shorten 2cm
Before you call the service: