 WARNING:

  Never place tools or other ob-

ject into the fan.

 WARNING:

  Never touch electrical compo-

nents with wet or damp hands.

 WARNING:

 To ensure the cooling unit 

works properly and at full capacity, make sure 

air supply to the unit is not obstructed.

 WARNING:

  Water temperature during sa-

nitation must not be higher than 25 °C!

 WARNING:

 Always make sure the power 

socket you intend to plug the cooler into is ac-

cessible, so that the appliance can be imme-

diately unplugged in case of emergency.

 WARNING:

 When unplugging the device 

from the socket, grab the plug and pull it out. 

Do not under any circumstances pull at the 

cable; risk of damage.

 WARNING

:  To turn the device off comple-

tely, unplug the appliance from the power soc-

ket.

 

WARNING:

  In the event the electrical wi-

ring of the product becomes damaged, sum-

mon a trained service technician. Do not under 

any circumstances repair the device yourself.

 WARNING:

 

The cooling system contains 

flammable coolant R290 (propane)!

 WARNING:

 Emergency maintenance and 

repair of the cooling system must be done by 

trained, authorised technicians familiar with 

cooling and electrical systems. The technicians 

should have special training and qualification 

for handling flammable substances in order to 

perform service on coolers containing  R290. 

Follow basic regulations and safety measures 

regarding service and repair!

 

WARNING:

  Do not use open flame or po-

tential sources of sparks in the vicinity of a 

cooler using 

R290 

coolant!

 WARNING:

  After unpacking, place the coo-

ler so that heat created by the cooling unit can 

be vented sufficiently.

 WARNING:

  Do not place objects that could 

prevent air circulation on top of the cooler.

5. INSTALLATION AND PLACEMENT:

Place the cooler onto a stable, level surface 

(maximum permitted inclination: 2 degrees). 

The appliance requires unobstructed air circu-

lation.

•  Ensure sufficient free space for air circulation 

and heat dissipation.

•  Ensure sufficient supply of fresh air.

•  The device must not be placed in an enclo-

sed space. 

•  The device must not be placed in the vicinity 

of heat sources or exposed to direct sunlight.

Minimum distance of vents from an obstac-

le that would limit air circulation must be 30 

cm. Minimum distance for sections with no air 

vents is 7 cm. Ideally, use the device in a cool 

and well-ventilated room. The device is desig-

ned for use at ambient temperature of at least 

16 °C and at most 32°C. 

 WARNING:

 

The device MUST NOT be used 

or stored at ambient temperature lower than 

0 °C.

 The device is designed for use in a normal 

environment, always under a roof, protected 

from rain or sunlight.  Climate class N. . 

  DANGER: 

  Protect the cooler and electri-

cal connection from rain and spraying water!

 WARNING:

  Do not under any circumstan-

ces lay the cooler on its side, not even during 

transport.

   NOTE:

  In order for the device to work 

correctly and at maximum output, it is im-

portant to not cover up any of the device‘s 

vents and ensure sufficient air circulation.

Summary of Contents for KONTAKT 55

Page 1: ...LINDR FLOW TYPE LUXURY COOLER Number 014 2020 REV00 Valid 2020 07 01 INSTRUCTION MANUAL ENGLISH...

Page 2: ...ains important information necessary to ensure that all operations are done pro perly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN T...

Page 3: ...Keg coupler assembly 12 Beverage supply connection and pressurisation 13 Beverage connections 14 Positioning of the thermostat 15 How to work with speed fittings 16 Temperature and adjustment 17 Keg t...

Page 4: ...ect use DO NOT USE THE DEVICE FOR PURPOSES OTHER THAN THOSE STATED BY THE MANU FACTURER General safety principles Observe the fo llowing safety instructions The supplier is not liable for damage cause...

Page 5: ...NING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the coo ler so that heat created by the cooling unit can be vent...

Page 6: ...nstructi on manual or the product s design as defined by the manufacturer Materials replaced du ring the validity period of the warranty are our property The legitimacy of the warranty claim is always...

Page 7: ...ed onto the bushing and affixed with a clip figure 7 A figure 7 b figure 7 E 1 Turn the compensator lever 1 so that it points down see figure The compensator lever on the tap is used to adjust the flo...

Page 8: ...ng onto the keg coupler figure 8 A figure 8 b figure 8 c figure 8 d WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a lip val...

Page 9: ...3 Compressor switch 4 Keg coupler A system S system M system 5 F 5 8x9 5mm speed fitting 6 F 5 8x8mm speed fitting 7 Beverage 12 2 Connection and Pressurisation by CO2 Bottle One Tap Device 1 Beverage...

Page 10: ...eed fitting 6 F 5 8 x 8 mm speed fitting 7 Y 8 x 8 x 8 mm speed fitting 8 Beverage 12 4 Connection and Pressurisation by Classic CO2 Bottle Two Tap Device 1 Beverage inlet 2 Keg coupler A system S sys...

Page 11: ...The set pressure will be displayed on the pressure gauge in bars The compressor can be turned off separately with a switch The air outlet from the cooler terminates in a 5 16 8 mm speed fitting marked...

Page 12: ...figure 12 B 14 POSITIONINGOFTHETHERMOSTAT 14 1 Positioning of the thermostat SOUDEK 20 Green Line Mechanical thermostat is located under the wooden cap on the back of the cooler figure 12 A 14 2 Posit...

Page 13: ...2 Speed Fitting Removal Hold the grey ring tight against the body of the speed fitting and pull out the hose figure 13 B WARNING If you do not hold the grey ring but pull at the hose the speed fitting...

Page 14: ...b figure 14 c figure 14 d figure 14 e 17 KEG TAPPING AND UNTAPPING 17 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the...

Page 15: ...ing a keg using an A system keg coupler A system keg coupler figure 15 d figure 15 e 17 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 15 a figure 15 b figure 15 c...

Page 16: ...WARNING If a leakage is found untap the keg according to point 17 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contac...

Page 17: ...iness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor...

Page 18: ...ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Sanitation Procedure Once you have finished a keg...

Page 19: ...use a sanitation adapter according to your type of keg coupler not included in standard ac cessories The cooler must be sanitised once every 14 days by a person with chemical engi neering qualificatio...

Page 20: ...50x415x490 34 0 KONTAKT 55 K PROFI GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 437 1 90 400x430x270 475 33 5 SOUDEK 50 3xKOH GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 322 1 40 350x415x...

Reviews: