Table of defects:
MALFUNCTION
CAUSE
REMOVAL
beverage does not flow
keg tapped incorrectly
check that the keg coupler lever is pushed
down
the keg is not pressurised
pressurise the keg
compensator is closed
move the compensator lever
beverage cooled
insufficiently
incorrect thermostat setting
turn the thermostat knob
to the right towards number 7
poor air circulation
check the cleanliness of condenser plates
device overheats
place the device in a colder environment
tap jerks, drink sprays out
pressure too high
reduce delivery medium supply, reduce
pressure in the
keg
beer foams excessively
reduce beverage temperature - turn
the thermostat knob to the right,
Speed fiting leaking
hose
incorrectly
inserted
pull out the hose, check that the end of the
hose is flat (not at an angle), level off with
a knife if needed
scratches on the hose
pull out the hose and shorten by ca. 2 cm
NOTE:
If the defect persists even after the above steps are taken, contact a service
centre.
Summary of Contents for Green Line AS-110-US
Page 2: ...2...
Page 15: ...15 14 Interconnecting beverege tubing The figure shows a model example of connection...
Page 19: ...19...
Page 20: ...20 2 Keg untapping...
Page 21: ...21 A system keg coupler...
Page 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...
Page 23: ...23...
Page 24: ...24 2 Keg untapping...
Page 28: ...28 Warning Disconnect the device from power before cleaning the condenser 1 2 3...
Page 29: ...29 4 5 6 7...
Page 34: ...34 27 Wiring diagram...
Page 35: ...35 28 Cooling diagram...
Page 36: ...36...