LINDR Green Line AS-110-US Manual Download Page 10

 

 

10

 

 

The device MUST NOT be used or stored 
at ambient temperature lower than 0 °C. 

The device is designed for use in a normal 
environment, always indoors, protected from 
rain or sunlight. Climate class N. 

  WARNING:

 Protect the cooler and 

electrical connection from rain and spraying 
water! 

WARNING:

 

Do 

not 

under 

any 

circumstances lay the cooler on its side, not 
even during transport. 

NOTE:

  In  order  for  the  device  to 

work correctly and at maximum output, it is 
important to not cover up any of the device's 
vents and ensure sufficient air circulation. 

6.

 

Electrical Connection: 

 

Connect  the  device  to  a  power  socket  in 
accordance  with  specifications  on  the 
product label of the device. Electrical wiring 
is  subject  to  local  regulations.  If  the  power 
lead (cable) is damaged, it must be replaced 
by  the  manufacturer,  the  manufacturer's 
service technician or a similarly 
qualified person to prevent risk of hazardous 
situations. 

 

WARNING:  Do  not  use  or  turn  on 

the  device  if  the  power  lead  (cable)  is 
damaged!

 

 

 

 

 

 

7.

 

Testing: 

The product is delivered ready for immediate 
use. 

8.

 

Warranty: 

The  device  comes  with  a  warranty  in 
accordance with general legal regulations of 
the  Czech  Republic  or  in  accordance  with 
the  trade  agreement.  During  the  validity 
period  of  the  warranty,  we  will  remove  any 
defects  on  the  product  free  of  charge, 
provided these defects were not caused by 
excess  wear,  improper  handling,  incorrect 
storage or by using the product in a way that 
is  counter  to  the  instruction  manual  or  the 
product's  design  as  defined  by  the 
manufacturer. Materials replaced during the 
validity  period  of  the  warranty  are  our 
property.  The  legitimacy  of  the  warranty 
claim  is  always  decided  by  an  authorised 
service  centre.  Warranty  provided  by  a 
retailer outside of the territory of the Czech 
Republic  is  governed  by  the  agreement 
between  the  retailer  and  the  buyer  in  their 
mutual  relationship;  this  agreement  is  not 
directly  linked  to  the  manufacturer.  The 
agreement does not give the buyer the right 
to 

submit 

warranty 

claims 

to 

the 

manufacturer.  Transport  expenses  or  other 
costs are not covered by the warranty. 

Attention: 

Electrical  devices  and  appliances  must  be 
checked/inspected  at  a  time  stipulated  by 
valid legislation of the country the device is 
operated in. Inspection of wiring may only be 
done by a person with valid authorisation for 
this activity. Service work, provision of spare 
parts  and  inspection  is  done  by  the 
manufacturer  or  an  authorised  service 
centre. 

Summary of Contents for Green Line AS-110-US

Page 1: ...VCH 02236 AS 110 us Green Line LINDR FLOW THROUGH WATER COOLING ENGLISH Number 007 2020 Valid 2020 01 01...

Page 2: ...2...

Page 3: ...al is an integral part of the device It must be stored in the vicinity of the device for the entirety of its service life and must be made available to the user any time the device is installed moved...

Page 4: ...stat placement 13 12 Temperature and adjustment 13 13 Putting into operation 14 14 Interconnecting beverage tubing 15 15 Pouring water into the tank 16 16 Keg tapping and untapping 18 17 How to work w...

Page 5: ...Not following instructions may cause injury or damage the device WARNING Risk of injury by electrical current NOTE This symbol indicates information and recommendations for the user WARNING The cooli...

Page 6: ...is set to max the device can accumulate a large amount of energy in the form of an ice bank which can then be used to dispense well cooled beers in quick sequence one after another The time required...

Page 7: ...hazard WARNING Cleaning and maintenance of the appliance on the part of the user must not be done by unsupervised children WARNING Before connecting to main electrical supply check that the voltage an...

Page 8: ...me or potential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the cooler so that heat created by the cooling unit can be vented sufficiently WARNING Do...

Page 9: ...9 V Clearances mm inch Model Top Rear Right Side Left Side Front AS 110 us 200 7 87 200 7 87 508 20 70 2 76 200 7 87...

Page 10: ...regulations of the Czech Republic or in accordance with the trade agreement During the validity period of the warranty we will remove any defects on the product free of charge provided these defects...

Page 11: ...cooler 1 Thermostat 6 Inlet beverage speed fiting 3 8 9 5mm 2 Main switch 7 Outlet beverage speed fiting 3 8 9 5mm 3 Pump socket 8 Outlet cold water speed fiting 1 2 12 7mm 4 Product label 9 Pump 5 P...

Page 12: ...erage inlets and outlets The beverage inlet and outlet is fitted with a 3 8 speed fiting 9 5 mm while the pump outlet is fitted with a 1 2 12 7 mm speed fiting Beverage outlet Beverage inlet Outlet co...

Page 13: ...of the cooler 12 Temperatureand adjustment The temperature of the cooled beverage is controlled by a mechanical thermostat The thermostat has a numerical scale of 1 7 Setting the thermostat to 6 7 cre...

Page 14: ...ctions are sufficiently tightened WARNING If leakage is found untap the keg according to point 16 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you...

Page 15: ...15 14 Interconnecting beverege tubing The figure shows a model example of connection...

Page 16: ...16 15 Pouring water into the tank 1 Remove the two screws holding the lid WARNING Always disconnect the device from power before pouring in water 2 Remote the lid...

Page 17: ...17 3 Pour water all the way up to the overflow the cooling coils must be submerged 4 Replace the lid and secure it with screws...

Page 18: ...18 16 KEG TAPPING AND UNTAPPING WARNING Make sure the adapter is clean before tapping the keg S system keg coupler Procedure for tapping and untapping a keg with an S system keg coupler 1 Keg tapping...

Page 19: ...19...

Page 20: ...20 2 Keg untapping...

Page 21: ...21 A system keg coupler...

Page 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...

Page 23: ...23...

Page 24: ...24 2 Keg untapping...

Page 25: ...be straight so that it plugs fully into the coupling If the hose will not go in moisten the end of the hose Speed fiting Removal Hold the grey ring tight against the body of the speed fiting and pull...

Page 26: ...e beverage tubing of the cooler after each use with pressurised water see Sanitation by Water To make flushing easier use a sanitation adapter according to your type of keg coupler not included in sta...

Page 27: ...a week check that the device is not exposed to radiant heat 1x a week check that air circulation is not obstructed 1x a month check the cooling unit s condenser and clean it regularly 1x a year have a...

Page 28: ...28 Warning Disconnect the device from power before cleaning the condenser 1 2 3...

Page 29: ...29 4 5 6 7...

Page 30: ...tion adapter is not included Can be purchased as an accessory for the cooler Sanitation procedure Once you have finished a keg connect the keg coupler to the sanitation adapter the same way as if you...

Page 31: ...leanliness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg beer foam...

Page 32: ...Components ALWAYS USE ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer 25 Spare parts When ordering...

Page 33: ...10 us Power Hp 1 5 Power W 820 Max output l hour 110 Sustained output l hour 60 Temperature difference t C 10 Coolant type R290 Voltage 115V 60Hz 1 Input power W 426 Current A 3 7 Coling coils 2 x 14...

Page 34: ...34 27 Wiring diagram...

Page 35: ...35 28 Cooling diagram...

Page 36: ...36...

Reviews: