14. TABLE OF MALFUNCTIONS:
Malfunction
Cause
Removal
beverage does not flow
keg tapped incorrectly
check that the keg coupler lever is pushed down
device with built-in compressor - turn on the switch
water from sanitation froze
turn off the device; then wait until the beverage starts
flowing again (may take a few minutes, or hours!)
compensator is closed
move the compensator lever on the tap
beverage cooled insuffi-
ciently
incorrect thermostat setting turn the thermostat knob to the right towards
number 7
poor air circulation
check the cleanliness of condenser plates
device overheats
place the device in a colder environment
tap jerks, drink sprays out
pressure too high
reduce delivery medium supply, reduce pressure in
the keg
air compressor does not
switch on
press the switch on the cooler
air compressor does not
switch off
leakage
pull out and reinsert the air hose, tighten the nuts
on the keg coupler
beer foams excessively
reduce beverage temperature - turn the thermostat
knob to the right
regulate flow rate by pushing the compensator lever
up
speed fittings leaking
hose poorly inserted
pull out the hose, check that the end of the hose is
flat (not at an angle), level off with a knife if needed
scratches on the hose
pull out the hose and shorten by ca. 2 cm
NOTE:
If the defect persists even after the above steps are taken, contact a service centre.
15. ENVIRONMENTAL PROTECTION
Waste Sorting
This product must not be disposed of in communal waste. Electrical waste in the Czech
Republic is disposed of within the Rema System (www.remasystem.cz).
In countries other than the Czech Republic, waste sorting is subject to local regulations.
Sorting waste allows recycling and reusing used products and packaging materials. Reuse
of recycled material helps protect the environment from pollution and reduces resource
consumption. Local regulations may regulate the method of disposing of household ap-
pliances at local collection points or at the point of sale.