and scroll
Then press “
Confirm
”
.
Scroll with the wheel to set the hour.
Press “
Confirm
”
again to set the minutes.
and scroll
Press “
Confirm
”
to set the current date.
P
AUTO
DAY
DAY
DAY
+
-
+
-
+
-
+
_
Use the
TOUCH PAD
to increase or
decrease the value.
Use the Confirm button to confirm and move
to the next setting.
Set the day of the week as follows:
day 1 = Monday
,
day 2 = Tuesday
,
day 3 = Wednesday
,
... ... day 7 = Sunday
DAY
°C
Lindab reserves the right to make changes without prior notice
202
2
-0
1
-
28
RHR-CF
lindab | we simplify construction
Installation i
nstructions
16.
10
Setting the clock and the day of the week
Press “
M
”; scroll with the wheel until the “
clock
” icon starts
flashing “
”.
Fig. 67
17. Supplementary functions
17.1 Booster mode
This is enabled by a remote control normally located in a
bathroom or kitchen.
The power board of the centralised unit receives the
pulse from the outside and enables the "Booster Mode"
In this case the "Boost" icon appears as a notification
on the screen of the unit's control panel.
Fig. 68
Like for “
Party Mode
”,
“
Booster Mode
” determines an
increase in the timed speed respect to the nominal speed.
The percentage of the duration and of the speed
increase of the ventilation unit can be configured by the
installer upon a specific request of the user.
The standard duration is 3 hours (default) and the
standard percentage is 130% beyond the nominal
speed.
Before standard duration ends, user can stop
Booster
mode by repeating the command on the remote
switch.
17.2 Fireplace function
If the unit is interfaced with an negative pressure
ambient pressure switch and is set in the DIP-SWITCH
configuration recommended in presence of a natural
draught chimney, the unit is automatically turned off when
the ignition of the fireplace causes negative pressure in
the room.
This occurs in order to prevent the ambient pressure
induced by the action of the dual flow ventilation unit
from counteracting the natural draught of the fireplace
and releasing smoke into the room.
17.3 Boiler function
If the unit is interfaced with a remote switch and is set in
the DIP-SWITCH configuration recommended in presence
of an atmospheric boiler, the unit is forced into a strong
imbalance supply mode in order to facilitate the ignition
of the boiler.
The mode remains active as long as the switch stays in
the activation position.
41