![Lincoln Impinger 3262BWEC Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/lincoln/impinger-3262bwec/impinger-3262bwec_operators-manual_1917795018.webp)
Impinger X2 –Operator Manual
18
UNITED STATES AND CANADA
NOTES:
1. The purpose of this diagram is to illustrate one form of high pressure gas supply system. The customer is
responsible for all modifications to the gas system. All modifications must meet all local codes, approved by your gas
supplier and made by a licensed plumber.
2. The gas regulator and meter are typically owned by the gas supplier and they are responsible for all modifications
and/or upgrades to this equipment.
3. Lincoln X-2 Ovens cannot guarantee oven performance if the minimum gas supply specifications are not met.
4. An increase in gas pressure will often cause all gas-fired appliances to operate more efficiently.
5. Gas Pressure Conversion: 1.0 Pound = 16 Ounces = 27.7 Inches Water Column (WC)
E-FLOW DUAL CONVEYOR OVENS
GAS PRESSURE ILLUSTRATION
Regulator
Meter
Incoming Gas
Supply (20 - 30
pounds pressure)
Restaurant Cross Section
Not to Scale
Ground
Level
Furnace Mounted
In Attic
Water Heater
LOW PRESSURE GAS INSTALLATION DIAGRAM
Low Pressure
(about 7" WC,
177.8 mm
MAXIMUM) to all
Appliances
17.4 m-Bar
2" NPT, (51 mm) Minimum Diameter
Regulator
Meter
Incoming Gas
Supply (20 - 30
pounds pressure)
HIGH PRESSURE GAS INSTALLATION
DIAGRAM for UNITED STATES & CANADA ONLY
High Pressure
(13” to 57" WC) to all
Appliances
2" NPT Minimum Diameter
= Step Down Regulator Mounted at Each Appliance
= Gas Pipe with High Pressure
Summary of Contents for Impinger 3262BWEC
Page 6: ...Impinger X2 Operator Manual 6...
Page 7: ...Impinger X2 Operator Manual 7...
Page 8: ...Impinger X2 Operator Manual 8 FIGURE A Rev 4 05...
Page 34: ...Impinger X2 Operator Manual 34 LABEL DEFINITIONS...
Page 41: ...9432 ELECTRIC UTILITY KIT UTILITY EXTENSION KIT INSTALLATION INSTRUCTIONS...
Page 46: ...This page intentionally left blank...
Page 52: ...Impinger X2 Operator Manual 52...