Impinger II –1100 Series Service Manual - Domestic
48
TO REVERSE CONVEYOR DIRECTION ON STEPPER DRIVE SYSTEM
1. Shut off power at main breaker.
2. Remove conveyor.
3. Remove front control box cover.
4. Change position of dip switch #1 on stepper control board as described on page 46.
5. Reassemble in reverse order.
TRANSFORMER - STEPPER MOTOR CONTROL
1. Shut off power at main breaker.
2. Remove conveyor.
3. Remove front cover.
4. Disconnect transformer wire harness.
5. Remove two (2) mounting screws.
6. Reassemble in reverse order.
HALL EFFECT SENSOR - REPLACEMENT
Remove two (2) mounting screws and remove sensor from conveyor motor. Reinstall in
reverse order.
TYPE OF GAS
INCHES of
CENTIMETERS of
kPa
Mbar
WATER
COLUMN
WATER COLUMN
NATURAL GAS
3.5" WC
8.9 cm WC
.87kPa
8.70Mbar
L..P. GAS
10"WC
25.4 cm WC
2.48kPa
24.8Mbar
CITY/TOWN GAS
1.4"WC
3.56 cm WC
.35kPa
3.5Mbar
AIR PRESSURE SWITCH, BURNER OR OVEN CAVITY
TO REPLACE AIR SWITCH
:
1. Shut off power at main breaker.
2. Remove conveyor.
3. Remove rear control compartment cover.
4. Remove cover of air switch exposing adjustment screw.
5. Disconnect and mark wires for proper reassembly.
6. Remove air tube and remove switch from hanger.
7. Reinstall in reverse order, making sure wires are properly attached and air tube is properly attached,
unblocked and aligned properly to avoid crimping.
TO CALIBRATE AIR SWITCH
:
1. If switch will not activate when blower pressure is supplied, turn adjustment screw counter clockwise (-).
2. If switch will not deactivate when blower pressure is eliminated, turn adjustment clockwise (+).
Summary of Contents for IMPINGER 1100
Page 8: ...Impinger II 1100 Series Service Manual Domestic 8 SCHEMATIC 1100 1101 ...
Page 9: ...Impinger II 1100 Series Service Manual Domestic 9 SCHEMATIC 1102 1103 ...
Page 10: ...Impinger II 1100 Series Service Manual Domestic 10 SCHEMATIC 1116 1117 S N 2011383 BELOW ...
Page 11: ...Impinger II 1100 Series Service Manual Domestic 11 SCHEMATIC 1116 1117 S N 2011384 ABOVE ...
Page 13: ...Impinger II 1100 Series Service Manual Domestic 13 SCHEMATIC 1130 1131 S N 2011384 ABOVE ...
Page 14: ...Impinger II 1100 Series Service Manual Domestic 14 SCHEMATIC 1160 1161 S N 2011978 ABOVE ...
Page 16: ...Impinger II 1100 Series Service Manual Domestic 16 SCHEMATIC 1132 1133 S N 2011384 ABOVE ...
Page 17: ...Impinger II 1100 Series Service Manual Domestic 17 SCHEMATIC 1162 1163 S N 2011978 ABOVE ...
Page 51: ...Impinger II 1100 Series Service Manual Domestic 51 BLOW UP GENERAL 1100 SERIES ...
Page 65: ...Impinger II 1100 Series Service Manual Domestic 65 BLOW UP OVEN BACK ASSEMBLY 1100 SERIES ...
Page 67: ...Impinger II 1100 Series Service Manual Domestic 67 BLOW UP GEARMOTOR ASSEMBLY 1100 SERIES ...
Page 69: ...Impinger II 1100 Series Service Manual Domestic 69 BLOW UP CONVEYOR DOOR 1100 SERIES ...
Page 71: ...Impinger II 1100 Series Service Manual Domestic 71 This page intentionally left blank ...
Page 72: ...Impinger II 1100 Series Service Manual Domestic 72 ...