![Lincoln cool arc 40 Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/lincoln/cool-arc-40/cool-arc-40_operators-manual_1917858013.webp)
A-4
INSTALLATION
COOL ARC
®
40
A-4
HORIZONTAL INSTALLATION ON THE
TOP OF A POWER SOURCE
Forproperinstallation,followtheinstructionsprovided
with the K559-2 Cooler Horizontal Mounting Bracket
Kit.Thecoolerissecuredtothepowersourceliftbale.
Referencethetablebelowforalistofpowersources
that allows the COOL ARC
®
40 to be mounted hori-
zontallyontop.
vERTICAL INSTALLATION ON POWER
SOURCE WITH A DUAL CYLINDER
UNDERCARRIAGE.
Forproperinstallation,followtheinstructionsprovided
withtheK559-3CoolerVerticalMountingBracketKit.
The cooler is securely mounted to the dual cylinder
supportbracket.Referencethetablebelowforalistof
power sources and dual cylinder undercarriages that
allowstheCOOLARC
®
40tobemountedverticallyat
therearofthemachineonthegasbottlerack.
If the COOL ARC
®
40 is not securely mounted hor-
izontally on top of a power source or vertically on
a dual cylinder undercarriage.
THE COOL-ARC 40 MUST BE OPERATED IN THE
HORIZONTAL POSITION. This will prevent the
cooler from being accidentally tipped over.
------------------------------------------------------------------------
Remove the connector nut from the InLET hose by
making a straight cut 6-12mm(1/4"-1/2") away from
theendofthenipplelocatedinsideofthehose.Take
the nipple and the connector nut ordered above and
insert the nipple into the connector nut so that the
threaded end of the connector nut points away from
thebarbedendofthenipple.Twistthebarbedendof
thenippleintothehose until the shoulder of the nip-
pleisflushwiththeendofthehose.Securethehose
ontothenipplewiththehoseclamptoinsurethatthe
connection is watertight. no water can leak from the
connectionifitisproperlyattached.Repeattheproce-
durefortheOUTLEThose.Whencomplete,followthe
connection procedure detailed above for connecting
thehosestotheCOOLARC
®
40fittings.
Theconnectorandnipplelistedfittightlyonto4.0mm
(5/32") to 4.8mm(3/16") inner diameter hose, but if
clamped tightly to the hose, can fit up to a
6.4mm(.25”)innerdiameterhose.
INPUT POWER CONNECTION
PlugtheinputpowercordontheCOOLARC
®
40into
astandard230Vcircuitbreakerprotectedreceptacle.
INSTALLATION ON UNDERCARRIAGE OR
POWER SOURCE
The COOL ARC
®
40 can be mounted either horizon-
tally or vertically on a power source. To mount the
cooler horizontally, order the K559-2 Cooler
HorizontalMountingBracket.Tomountthecoolerver-
tically on a power source with a dual cylinder under-
carriage, order K559-3 Cooler Vertical Mounting
Bracket.
Power Source
Cv-300
Cv-400
Cv-655
DC-250
DC-400
DC-600, DC-655
Square Wave TIG 275
Square Wave TIG 355
Power Wave 455
Power MIG 255
K559-3
Cooler vertical Mounting
Bracket on a Dual
Cylinder Undercarriage
K874 Undercarriage
Not Available
Not Available
Not Available
Not Available
Not Available
K932-1 Undercarriage
Not Available
K1570-1 Undercarriage
Not Available
K559-2
Cooler Horizontal
Mounting Bracket
Can be used On Top
of a Power Source
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
WARNING