K2187-1(COOLARC
®
40230VInternational)
ViaContinentalEuropean(SCHUKO)-PROnGPLUG
220-240VAC50/60Hz1Phase
1.3-1.7Amps
2.0-2.4Amps
60psi(414kPa)(4.14bar)Max.
1.66gal/min.(6.28liter/min)Max.
53-57psi(365-393kPa)
.45-.60gal/min.(1.7-2.3liter/min)
2.0ga.(7.6liters)
For Use Above Freezing:
Use Cleantap,distilledorde-ionizedwater.
For Use Below Freezing:
Use50%waterand50%pureethyleneglycol
(reagentorindustrialgrade)mixture.
DO NOT USE:
Automotive anti-freeze that contains rust inhibitors or leak stoppers.
Thesecoolantswilldamagethepumpandblockthesmallinternalpassagewaysofthe
heatexchanger,affectingcoolingperformance.Toacquirethepropercoolantcontact
alocalweldingdistributor.
DO NOT USE:
Pre-packagedweldingindustrycoolants
◊
.Thesecoolantsmaycontain
oil-basedsubstances,whichattacktheplasticcomponentsofthecooler.Onceadded
tothecooler,thesesubstancesarevirtuallyimpossibletopurgefromthewaterlines
andheatexchanger.
◊
MagnumProALcoolantmaybeused.
46.5lbs.(21.1kg)
61.2lbs.(27.8kg)
9.03in.(229.4mm)
9.10in.(231.1mm)
31.99in.(812.6mm)
34.26in.(870.2mm)
A-1
INSTALLATION
COOL ARC
®
40
A-1
Productno./Model
Input
CurrentDraw@60HzInput
CurrentDraw@50HzInput
MaximumOperatingPressureandFlowRate
(OpenFlow,WithoutWeldingTorchRestriction)
TypicalOperatingPressureandFlowRate
(WithWeldingTorchRestriction)
ReservoirSize
RecommendedCoolant
Shipping
Weight
Reservoir
Full(Water)
L
W
Dimensions
H(TopFace)
HTopHandle)
TECHNICAL SPECIFICATIONS – COOL ARC
®
40
EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT
OFF
OFF
O
ON
IP 21S