background image

Page 10 

 

Form   403599

To set the pause time, remove the cover on the pump 

  housing.

Important:

 After having set the pause time, screw the cover on 

the pump housing again.

Fig. 12 - The cover to the printed circuit board has been remo-

ved

Time Setting

Fig. 13 - Rotary switch - Pause time

To set the pause time

The pause time can be adjusted to 15 settings by means of the 

blue rotary switch

.

 

Note: The 0 position corresponds to the shortest time, see pos. 

1.

•  To check the function of the pump it is possible to perform an 

operational test.

*  If necessary, switch on the battery voltage

*  Switch on the driving switch

•  To check whether power is applied to the printed circuit board, 

observe whether the left-hand LED 1, Fig. 14, is lit.

*  Press the pushbutton  

(> 2 seconds)

 for triggering an additio-

nal lubrication (illuminated pushbutton, Fig. 11, or pushbutton 

on the switch cabinet) until the right-hand LED 3 lights up.

•  The right-hand LED indicates the following functions:

-  operating time

-  monitoring time (in normal cases it is as long as the 

  operating time, in the case of a fault: 30 minutes)

-  faults

•  When  an  additional  lubrication  cycle  has  been  triggered,  a 

shorter pause time occurs, followed by a normal 

  lubrication cycle.

•  Additional lubrication cycles can be triggered at any time.

Fig. 14 - LED of the printed circuit board

1 -  LED, left-hand 

3 -  LED, right-hand,

  Power supply 

  Indication of operation

2 -  Rotary switch 

4 -  Pushbutton for

  ”pause time” 

  additional lubrication 

   

  cycle

Operational Test /To Trigger an Additional 

Lubrication Cycle

Switch position 1 2 3 4 5 6 7 8 9 A B C D E F

Minutes

4 8 12 16 20 24 28 32 36 40 44 48 52 56 60

Summary of Contents for 94822

Page 1: ...Model 94822 CHASSIS LUBE ELECTRIC GREASE PUMP Series C Section Page Q3 FEB 2006 FORM 403599 14C ...

Page 2: ...cation cycle If a signal is not received within 30 minutes a fault signal as described above will also occur This feature is used to monitor the pump s operation and to detect any blocked or broken supply lines Do not use pump without pressu re relief valve The pump consists of a pump housing electric gear motor the microprocessor and a plastic reservoir with stirring paddle The high operating pre...

Page 3: ...Form 403599 Page 3 MOUNTING HOLE LOCATIONS Figure 3 Figure 2 ...

Page 4: ... 246426 17 Closure plug 2 246422 18 3 wire internal plug 1 273483 19 5 wire internal plug 1 273484 20 5 wire power cord plug 4 273485 22 Sealing plug 1 246423 23 Nipple 1 226 14105 5 24 Screw 10 206 13796 7 25 Grease fitting 1 5050 26 Microprocessor 1 249905 27 Woodruff key 1 part of Kit 246436 28 Radial seal 1 part of Kit 246436 246437 29 24 VDC motor 1 part of Kit 246436 30 Housing cover 1 24642...

Page 5: ...ial seal 28 1 24 VDC motor 29 1 Plug for motor 38 Housing Seal Kit contains 246437 3 O ring 15 1 Radial seal 28 247671 1 Lid 42 247674 1 Reservoir 1 247676 1 Hose 2 247677 1 O ring 44 247678 1 Adapter 45 249903 1 Control Cam 4 249904 1 Magnetic Switch 48 249905 1 Microprocessor 26 270864 1 Pressure relief assembly 37 273483 1 3 wire internal plug 18 273484 1 5 wire internal plug 19 273485 1 5 wire...

Page 6: ...3599 When replacing service part 249905 microprocessor circuit board check to see that the jumpers in the new board are positioned the same as the old board See illustration below showing location of the five jumpers ...

Page 7: ...Form 403599 Page 7 SYSTEM ACCESSORIES DESCRIPTION PART NO PUSHBUTTON LIGHT 24 VDC 241484 8 AMP FUSE 241052 FUSE HOLDER 241053 Figure 5 ...

Page 8: ...p by an electronic memory EEPROM until the time which has been set on the blue rotary switch is reached After the machine contact or ignition switch is switched on again the printed circuit board operates from the point where it had been interrupted If the setting is modified within the pause time the printed cir cuit board takes over the new value only at the end of the operating time The pause t...

Page 9: ...contact or driving switch must be switched on To acknowledge a Fault Functional check Each time the machine contact external contact or the driving switch is switched on a functional check of the drive motor and signal lamp takes place automatically During the functional check the motor is switched on for 0 1 second the stirring paddle slightly rotates and the signal lamp lights up for 2 seconds I...

Page 10: ... Fig 14 is lit Press the pushbutton 2 seconds for triggering an additio nal lubrication illuminated pushbutton Fig 11 or pushbutton on the switch cabinet until the right hand LED 3 lights up The right hand LED indicates the following functions operating time monitoring time in normal cases it is as long as the operating time in the case of a fault 30 minutes faults When an additional lubrication c...

Page 11: ... 1 second OFF Low level control The signal lamp is flashing with the following frequency Reservoir empty E 0 5 second ON 0 5 second OFF Fault Indication Fig 15 Flashing frequencies in the case of malfunctions A Drive motor defective B Lubrication circuit 1 malfunctioning E In the case of low level control reservoir empty F Fault acknowledged maintained lightening Note The low level signal is conve...

Page 12: ... switch and check it For this insert a metallic pin into the borehole of the detector Let it there over 2 seconds and then remove it If the pump is not switched off afterwards check the cable connections to the pump If necessary replace the proximity switch along with the connector Check the cable connections to the pump If necessary replace the proximity switch with the connector Replace the prin...