To set the pause time, remove the cover on the pump
housing.
Important:
After having set the pause time, screw the cover on
the pump housing again.
Fig. 12 - The cover to the printed circuit board has been remo-
ved
Time Setting
Fig. 13 - Rotary switch - Pause time
To set the pause time
The pause time can be adjusted to 15 settings by means of the
blue rotary switch
.
Note: The 0 position corresponds to the shortest time, see pos.
1.
• To check the function of the pump it is possible to perform an
operational test.
* If necessary, switch on the battery voltage
* Switch on the driving switch
• To check whether power is applied to the printed circuit board,
observe whether the left-hand LED 1, Fig. 14, is lit.
* Press the pushbutton
(> 2 seconds)
for triggering an additio-
nal lubrication (illuminated pushbutton, Fig. 11, or pushbutton
on the switch cabinet) until the right-hand LED 3 lights up.
• The right-hand LED indicates the following functions:
- operating time
- monitoring time (in normal cases it is as long as the
operating time, in the case of a fault: 30 minutes)
- faults
• When an additional lubrication cycle has been triggered, a
shorter pause time occurs, followed by a normal
lubrication cycle.
• Additional lubrication cycles can be triggered at any time.
Fig. 14 - LED of the printed circuit board
1 - LED, left-hand
3 - LED, right-hand,
Power supply
Indication of operation
2 - Rotary switch
4 - Pushbutton for
”pause time”
additional lubrication
cycle
Operational Test /To Trigger an Additional
Lubrication Cycle
Switch position 1 2 3 4 5 6 7 8 9 A B C D E F
Minutes
4 8 12 16 20 24 28 32 36 40 44 48 52 56 60