SPECIFICATIONS
Airmotor effective dia. in.
2.5
Air inlet
1/4 NPTF
Material outlet
1/4 NPTF
Ratio
50:1
Delivery output, cubic inches per minute
80
Delivery in cubic inches per cycle
.35©
Minimum air pressure
30 p.s.i.
Maximum air pressure
150 psi.
Max output pressure
7500 p.s.i.
Noise level @ 120 psig
<85 dBA
OWNER/OPERATOR MANUAL
DESCRIPTION
Model 82050 is an air operated chassis
pump designed to pump low and medi-
um viscosity materials (grease) from
drums and pails.
OWNER/OPERATOR
RESPONSIBILITY
It is the owners/operators responsibility
to properly use and maintain this equip-
ment.
The instructions and warnings con-
tained in this manual shall be read and
understood by the owner/operator prior
to operating this equipment.
If an owner/operator does not under-
stand English, the contents of this man-
ual shall be explained in the owners
operators native language to assure the
owner/operator comprehends.
It is the owners/operators responsibility
to maintain the legibility of all warning
and instruction labels.
The owner/operator shall retain this
manual for future reference to important
warnings, operating and maintenance
instructions.
SAFETY INFORMATION
Read and understand all warnings, cau-
tions and instruction before operating
this equipment. Extreme caution should
be used when operating this equipment
as personal injury and/ or property dam-
age can result from equipment misuse.
Adequate personal protection is recom-
mended to prevent splashing of materi-
al on the skin or in the eyes. ALWAYS
disconnect air coupler from pump when
the pump is not being used.
One Lincoln Way
St. Louis, MO 63120-1578
Phone +1.314.679.4200
Fax +1.800.424.5359
© Copyright 2002
Printed in USA
Web site:
www.lincolnindustrial.com
© Indicates change