F-5
TROUBLESHOOTING & REPAIR
F-5
WIRE-MATIC 250
TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual
OUTPUT PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
The output voltage and wire feed is
present continuously or pulsing
when gun trigger is NOT activated.
1.
Check the machine's internal
trigger leads for grounds or
shorts. See Wiring Diagram.
2.
The control board may be faulty.
Replace.
1.
Remove the gun. If the problem
is resolved the gun trigger circuit
is faulty. Repair or replace.
2.
If the problem is not resolved
then contact your Local Lincoln
Electric Authorized Field
Service Facility.