VANTAGE® 580
(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity.
When welding, available auxiliary power will be reduced.
(2) Reduced to less than 30V in the CC-stick Mode when VRD (VOLTAGE REDUCTION DEVICE) is on.
(3) Maximum per circuit breaker rating.
(4) To Top of enclosure. Add 7.35 (186.7mm) to top of exhaust. Add 3.87”(98.3mm) to top of Lift Bail.
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS - VANTAGE® 580 (K2963-1)
Make/Model
Description
Speed (RPM)
Displacement
Starting
Capacities
cu. in. (ltrs.)
System
4 cylinder
135.6(2.2)
12VDC Battery &
Fuel: 20 gal.
43 HP
High Idle 1850
starter
(75.7 L)
PERKINS
1850 RPM
Bore x Stroke inch (mm)
(Group 34; 650 Oil: 8.45Qts. (8L)
404D-22T Turbo Charged
Full Load 1850 cold crank amps)
water cooled
3.43 X 3.64
65 Amp Alternator
Radiator Coolant:
Diesel Engine
Low Idle 1400
(87.1 x 92.5mm)
W / Built in Regulator
11.5 Qts. (10.9L)
INPUT - DIESEL ENGINE
RATED OUTPUT @ 104° F (40° C) - WELDER
LUBRICATION EMISSIONS
FUEL SYSTEM
GOVERNOR
Full Pressure
EPA Tier 4
Mechanical Fuel Pump, Auto air bleed
Electronic
with Full Flow Filter
Interim Compliant system, Electric shutoff solenoid, Indirect fuel injection.
AIR CLEANER
ENGINE IDLER
MUFFLER
ENGINE PROTECTION
Low noise Muffler:
Shutdown on low oil
Single Element
Automatic Idler
Top outlet can be rotated. pressure & high engine
Made from long life, aluminized steel. coolant temperature
ENGINE WARRANTY:
2 years / 2000 hours, all non-electric components, 3 years major non-electric compo-
nents . See Perkins warranty for details.
Welding Process
DC Constant Current
DC Pipe Current
Touch-Start™TIG
DC Constant Voltage
Arc Gouging
Output Range
30 TO 525 AMPS
40 TO 300 AMPS
20 TO 250 AMPS
14 TO 40 VOLTS
200 TO 580 AMPS
Max. Weld OCV
@Rated Load RPM
60 Volts
(2)
60 Volts
Welding Output
Current/Voltage/Duty Cycle
500A / 40V / 100%
525A / 38V / 60%
300A / 32V / 100%
250A / 30V / 100%
500A / 40V / 100%
525A / 38V / 60%
500A / 40V / 100%
Auxiliary Power
(1)
(60 Hz)
Outlets x Phase
Voltage
Power
Amps
1 x 3ph
415 Volts
20 Kva
28 Amps
2 x 1ph
240 Volts
7.2 Kva
15 Amps
ENGINE
RATED OUTPUT @ 40° C (104° F)
.
- GENERATOR
HEIGHT WIDTH
DEPTH
WEIGHT
35.94
(4)
in. 27.05 in 62.59 in.
913 mm
687 mm
1590 mm
PHYSICAL DIMENSIONS
1290 lbs. (586kg.)
Summary of Contents for VANTAGE 580
Page 40: ...F 1 DIAGRAMS F 1 VANTAGE 580...
Page 41: ...F 2 DIAGRAMS F 2 VANTAGE 580...
Page 42: ...F 3 DIAGRAMS F 3 VANTAGE 580...
Page 43: ...F 4 DIAGRAMS F 4 VANTAGE 580...
Page 44: ...F 5 DIAGRAMS F 5 VANTAGE 580...
Page 45: ...F 6 DIAGRAMS F 6 VANTAGE 580...
Page 46: ...F 7 DIAGRAMS F 7 VANTAGE 580...
Page 47: ...F 8 DIAGRAMS F 8 VANTAGE 580 2 9 0 3 2 9 03...