B-2
OPERATION
B-2
WELDING CONTROLS
(Figure B.1)
1. OUTPUT CONTROL-
The OUTPUT dial is used to preset the
output voltage or current as displayed on the digital meters for the
five welding modes. When in the CC-STICK, DOWNHILL PIPE,
ARC GOUGING or CV-WIRE modes and when a remote control
is connected to the 6-Pin or 14-Pin Connector, the auto-sensing
circuit automatically switches the OUTPUT CONTROL from con-
trol at the welder to the remote control.
In the CV-WIRE mode, if the feeder being used has a voltage con-
trol when the wire feeder control cable is connected to the 14-Pin
Connector, the auto-sensing circuit automatically makes OUTPUT
CONTROL inactive and the wire feeder voltage control active.
Otherwise, the OUTPUT CONTROL is used to preset the voltage
When in the DOWNHILL PIPE mode and when REMOTE CON-
TROL is connected to the 6-Pin or 14-Pin Connector, the OUT-
PUT CONTROL is used to set the maximum current range of the
OUTPUT CONTROL of the REMOTE.
Example:
When the OUTPUT CONTROL on the welder is set to 200
amps the current range on the REMOTE CONTROL will be 40-200
amps rather than the full 40-300 amps. Any current range that is less
than the full range provides finer current resolution for more fine tun-
ing of the output.
When in the TOUCH START TIG mode and when an Amptrol is
connected to the 6-Pin Connector, the OUTPUT dial is used to
set the maximum current range of the CURRENT CONTROL of
the Amptrol.
2. DIGITAL OUTPUT METERS-
The digital meters allow the
output voltage (CV-WIRE mode) or current (CC-STICK, DOWN-
HILL PIPE, ARC GOUGING and TIG modes) to be set prior to
welding using the OUTPUT control dial. During welding, the
meter display the actual output voltage (VOLTS) and current
(AMPS). A memory feature holds the display of both meters on
for seven seconds after welding is stopped. This allows the oper-
ator to read the actual current and voltage just prior to when
welding was ceased.
While the display is being held the left-most decimal point in
each display will be flashing. The accuracy of the meters is +/-
3%.
3. WELD MODE SELECTOR SWITCH-
(Provides five selectable welding modes)
CV-WIRE
ARC GOUGING
DOWNHILL PIPE
CC-STICK
TOUCH START TIG
VANTAGE
®
500 (CE)
1
9
11
20
7
4
10
5
8
12
13
15
19
6
21
22
14
18
17
16
2
3
FIGURE B.1 (CODES 11298, 11299, 11524, 11525, 11574, 11575, 11963)