8695 5240 / M
F - MAINTENANCE
SUBARC 5 - DX7
F-45
2 - TROUBLESHOOTING
Possible symptoms
Probable causes
Possible remedies
No wire feed and wire retraction
Power supply fault
Check fuse supply.
Fu 1-2-3-4
Mechanical blocking.
Check wire supply.
Belt cut.
Change the belt
Motor breakdown
Test the motor
Check the brushes.
Breakdown of the variable
speed unit.
Check the variable speed unit, its
connections and its supply, and change it
if necessary.
Red led lit up on cycle board
No manual and auto cycle.
Switch off the power supply and switch
on again.
If the led remains lit up, change the
board.
Green led switched off on cycle
board
Check the power supply of the board.
Check the fuses : Fu 5-6
High instability during welding
Defective wire drive.
Tighten the rollers.
Check wire supply
Power source fault
See power source instructions
Current supply fault.
Check power cables.
Defective flux supply.
Flux too dirty.
Change the flux.
Flux supply pipe clogged.
Disassemble and clean the flux supply.
Flux solenoid valve not
controlled
Check the power supply of the valve
24v
Check fuse : Fu 7
Summary of Contents for SUBARC 5
Page 10: ...B SAFETY INSTRUCTIONS 8695 5240 M B 4 SUBARC 5 DX7 ...
Page 13: ...8695 5240 M C DESCRIPTION SUBARC 5 DX7 C 7 ...
Page 30: ...D ASSEMBLY CONNECTION 8695 5240 M D 24 SUBARC 5 DX7 ...
Page 33: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 27 ...
Page 34: ...D ASSEMBLY CONNECTION 8695 5240 M D 28 SUBARC 5 DX7 ...
Page 35: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 29 ...
Page 39: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 33 ...
Page 40: ...8695 5240 M E 34 SUBARC 5 DX7 E OPERATOR MANUAL 1 FRONT PANEL OF THE POWER UNIT ...
Page 42: ...E OPERATOR MANUEL 8695 5240 M E 36 SUBARC 5 DX7 2 CONTROL BOX ...
Page 52: ...F MAINTENANCE 8695 5240 M F 46 SUBARC 5 DX7 ...
Page 54: ...F MAINTENANCE 8695 5240 M F 48 SUBARC 5 DX7 ...
Page 56: ...F MAINTENANCE 8695 5240 M F 50 SUBARC 5 DX7 ...