8695 5240 / M
E - OPERATOR MANUEL
SUBARC 5 - DX7
E-43
10 - PREPARATIONS BEFORE WELDING ON CONTROL UNIT (MIG)
NB: for the controls of
D2C SAW
, refer to the
instructions: 8695 6051
MANUAL CONTROLS
wire feed up
wire feed down
hight wire feed speed.
gas test
PREPARATION
Make sure that the gas supply is adjusted and in operation
11 - WELDING (MIG) VERSION
SUBARC 5
Press P6
and keep it pressed in (if you do not want to use the pre-gas C19)
the flux
flows
Release P66
Before welding start the flux flows for the duration of the timeout (adjustment by C 19). Once
welding is established, improve the adjustments of US and IS with potentiometers P1 and P5
Press P7
to stop welding
INFORMATION
Storing the welding parameters
SAW only
It is possible to store the welding parameters by pressing P6 during welding
After welding stops, the parameters taken into account during the pulse are restituted on the
display units
12 - MIG WELDING, VERSION
D2C SAW
Refer to the instructions for
D2C SAW
: 8695 6051
Summary of Contents for SUBARC 5
Page 10: ...B SAFETY INSTRUCTIONS 8695 5240 M B 4 SUBARC 5 DX7 ...
Page 13: ...8695 5240 M C DESCRIPTION SUBARC 5 DX7 C 7 ...
Page 30: ...D ASSEMBLY CONNECTION 8695 5240 M D 24 SUBARC 5 DX7 ...
Page 33: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 27 ...
Page 34: ...D ASSEMBLY CONNECTION 8695 5240 M D 28 SUBARC 5 DX7 ...
Page 35: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 29 ...
Page 39: ...8695 5240 M D ASSEMBLY CONNECTION SUBARC 5 DX7 D 33 ...
Page 40: ...8695 5240 M E 34 SUBARC 5 DX7 E OPERATOR MANUAL 1 FRONT PANEL OF THE POWER UNIT ...
Page 42: ...E OPERATOR MANUEL 8695 5240 M E 36 SUBARC 5 DX7 2 CONTROL BOX ...
Page 52: ...F MAINTENANCE 8695 5240 M F 46 SUBARC 5 DX7 ...
Page 54: ...F MAINTENANCE 8695 5240 M F 48 SUBARC 5 DX7 ...
Page 56: ...F MAINTENANCE 8695 5240 M F 50 SUBARC 5 DX7 ...