Intoduction 

 

SPEEDTEC 505SP BR

 inverter power source has been 

designed to work with the wire feeders: 

PF40, PF42,

 

PF44

PF46, PF22, PF26,

 

LF45

LF45S

. The ArcLink

®

 

protocol is used for communication between the power 
source and wire feeder. 
The power source-wire feeder configuration allows the 
welding: 

 GMAW 

(MIG/MAG) 

  FCAW-GS / FCAW-SS 

 SMAW 

(MMA) 

  GTAW (arc ignition using lift TIG). 

 

SPEEDTEC 505SP

 

BR

 works with the water cooler 

COOLARC 46

The complete packaging includes the following items: 

  Inverter power source 

  CD with Operator’s Manual 

  Slow-blow fuse – 2A (2 units) 

  Slow-blow fuse – 6,3A (1 unit) 

  Slow –blow fuse – 12.5A (1 unit). 

 
Recommended equipment, which can be bought by user, 
was mentioned in the chapter "Accessories". 
 

 

Installation and Operator Instructions 

 
Read this entire section before installation or operation of 
the machine. 
 

Location and Environment 

This machine will operate in harsh environments. 

 

However, it is important that simple preventative 
measures are followed to assure long life and reliable 
operation. 

  Do not place or operate this machine on a surface with 

an incline greater than 15° from horizontal. 

  Do not use this machine for pipe thawing. 

  This machine must be located where there is free 

circulation of clean air without restrictions for air 
movement to and from the air vents.  Do not cover the 
machine with paper, cloth or rags when switched on. 

  Dirt and dust that can be drawn into the machine 

should be kept to a minimum. 

  This machine has a protection rating of IP23.  Keep it 

dry when possible and do not place it on wet ground 
or in puddles. 

  Locate the machine away from radio controlled 

machinery.  Normal operation may adversely affect 
the operation of nearby radio controlled machinery, 
which may result in injury or equipment damage.  
Read the section on electromagnetic compatibility in 
this manual. 

  Do not operate in areas with an ambient temperature 

greater than 40°C. 

 

Duty cycle and Overheating 

The duty cycle of a welding machine is the percentage of 
time in a 10 minute cycle at which the welder can operate 
the machine at rated welding current. 
 
Example: 60% duty cycle 
 

 

Welding for 6 minutes. 

Break for 4 minutes. 

 
Excessive extension of the duty cycle will cause the 
thermal protection circuit to activate. 
 

 

 Minutes 

 

or 

decrease 

duty cycle 

 

 

Input Supply Connection 

 

 WARNING 

Only a qualified electrician can connect the welding 
machine to the supply network. Installation the outlet 
plug to power lead and connecting the welding machine 
had to be made in accordance with the appropriate 
National Electrical Code and local regulations. 
 
Check the input voltage, phase, and frequency supplied to 
this machine before turning it on. Verify the connection of 
grounding wires from the machine to the input source. 

SPEEDTEC 505SP BR

 can only be connected to a 

mating grounded receptacle. 
The input voltage is 380V 50/60Hz 3phase or 440V 50-
60Hz 3phase and it can be selected using the input 
voltage switch. For more information about input supply 
refer to the technical specification section of this manual 
and to the rating plate of the machine. 
 
Make sure that the amount of mains power available from 
the input supply is adequate for normal operation of the 
machine. The type of protection and cable sizes are 
indicated in the technical specification section of this 
manual. 
 

 WARNING

 

The welding machine can be supplied from a power 
generator of output power at least 30% larger than input 
power of the welding machine. 
See "Technical Specifications" chapter. 
 

 WARNING

 

When powering welder from a generator be sure to turn 
off welding machine first, before generator is shut down, 
in order to prevent damage to welding machine! 
 
Refer to points [1], and [8] of the images below. 
 

Summary of Contents for SPEEDTEC 505SP BR

Page 1: ...IM3061 01 2020 REV03 SPEEDTEC 505SP BR OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Page 2: ...ence record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 Electromagnetic Compatibility EMC 2 Safety 3 Intoduction 5 Installation and Operator Instructions 5 WEEE 10 Spare Parts 10 Authorized Service Shops Location 10 Elec...

Page 3: ...Output Voltage GMAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc FCAW 60Vdc 60 500A 39Vdc 100 390A 33 5Vdc SMAW 60Vdc 60 500A 40Vdc 100 390A 35 6Vdc GTAW 60Vdc 60 500A 30Vdc 100 390A 25 6Vdc WELDING CURRENT RANGE GMAW FCAW SMAW GTAW 20A 500A 20A 500A 5A 500A 5A 500A RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse Type gR or Circuit Breaker Type Z Power Lead 380V 40A 4 Conductor 4mm2 440V 32A DIMENSION Weight ...

Page 4: ...esses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area and...

Page 5: ...AL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipment PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard FUMES AND GASES CAN BE DANGEROUS Welding may produce fumes and gases hazardous to health Avoid breathing these ...

Page 6: ...g away from those parts during machine starting operating and servicing SAFETY MARK This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock The manufacturer reserves the right to make changes and or improvements in design without upgrade at the same time the operator s manual ...

Page 7: ...or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle and Overheating The duty cycle of a welding machine is the percentage of time in a 10 minute cycle at which the welder can operate the machine at rated welding current Example 60 duty cycle Welding for 6 minutes Break for 4 minutes Ex...

Page 8: ...idual code digits are flashed in red with a long pause between digits If more than one code is present the codes will be separated by green light Read the error code before the machine is turned off If occurs to clear the error try to turn Off the machine wait for a few seconds then turn ON again If the error remains a maintenance is required Please contact the nearest authorized technical service...

Page 9: ...s chapter Description of the User Interface is available in the operator s manual od wire feeder IM3028 IM3034 IM3045 IM3046 IM3052 IM3053 and the Guide supplied with a Replaceable Front Panel Welding Cables Connection Insert the plug of the work lead into the socket 5 The other end of this lead connects to the work piece with the work clamp Connect the wire feeder to the power source Insert the p...

Page 10: ... indicator 3 will turn on The power source is also electronically protected against overload and accidental short circuit The overload and short circuit protection circuit automatically reduces the output current to a safe value when it detects an overload Transport Lifting WARNING Falling equipment can cause injury and damage to unit Figure 8 During transportation and lifting with a crane adhere ...

Page 11: ... be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers ...

Page 12: ...er is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instruc...

Page 13: ...CI Lincoln Arclink Communication Interface K14106 1 PF40 Digital Wire Feeder K14107 1 PF42 Digital Wire Feeder K14108 1 PF44 Digital Wire Feeder K14109 1 PF46 Digital Wire Feeder K14110 1 PF22 Digital Wire Feeder K14138 1 PF26 Digital Wire Feeder K14121 1 Replaceable Front Panel with User Interface U2 K14122 1 Replaceable Front Panel with User Interface U4 K14123 1 Replaceable Front Panel with Use...

Reviews: