1.a. Turn the engine off before troubleshooting and maintenance

work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes 
outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame weld-

ing arc or when the engine is running. Stop
the engine and allow it to cool before refuel-
ing to prevent spilled fuel from vaporizing on
contact with hot engine parts and igniting. Do
not spill fuel when filling tank. If fuel is spilled,
wipe it up and do not start engine until fumes
have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in posi-

tion and in good repair.Keep hands, hair, clothing and tools
away from V-belts, gears, fans and all other moving parts
when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety

guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.

___________________________________________________

1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.

i

SAFETY

i

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ‘95

ELECTRIC AND 
MAGNETIC FIELDS
may be dangerous

2.a. Electric current flowing through any conductor causes 

localized Electric and Magnetic Fields (EMF). Welding 
current creates EMF fields around welding cables and 
welding machines

2.b. EMF fields may interfere with some pacemakers, and

welders having a pacemaker should consult their physician
before welding.

2.c. Exposure to EMF fields in welding may have other health

effects which are now not known.

2.d. All welders should use the following procedures in order to

minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure

them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and

work cables. If the electrode cable is on your right 
side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as

possible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove the

radiator pressure cap when the engine is
hot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.

The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.

The Above For Diesel Engines

The Above For Gasoline Engines

Summary of Contents for SAE400 WELD'N AIR

Page 1: ...reased by proper installation and thoughtful opera tion on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And mos...

Page 2: ...R WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Page 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for co...

Page 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Page 5: ...s appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise pai...

Page 6: ...v SAFETY v WARNING Assure that tank and compressor relief valves work properly and are at correct pressure settings NEVER move compressor with pressure in tank DO NOT modify or repair air tank...

Page 7: ...vi SAFETY vi...

Page 8: ...ation below for future reference This information can be found on your machine nameplate Product _________________________________________________________________________________ Model Number ________...

Page 9: ...1 General Description B 1 Recommended Applications B 2 Welder B 2 Auxiliary Power B 2 Compressed Air B 2 Product Application B 2 Design Features and Advantages B 2 Duty Cycle B 2 Engine Controls Funct...

Page 10: ...OR AIR COMPRESSOR OUTPUT SAE400 WELD N AIR ONLY Duty Cycle 1 Welding Output Volts at Rated Amps 60 NEMA 400 amps 36 volts 60 Lincoln Plus 400 amps 40 volts Welding Range Open Circuit Voltage Auxiliary...

Page 11: ...urface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least 06 1 6mm thick which should extend not less than 5 90 150mm beyond the equipme...

Page 12: ...es lights fend ers etc VEHICLE MOUNTING Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other compo nents to fail Only transport this equipment on serviceable ve...

Page 13: ...oading occasional moder ate to heavy loading of the engine may sometimes be necessary Caution must be observed in correctly loading a diesel generator unit 1 Connect the welder output studs to a suita...

Page 14: ...pper cable sizes recom mended for the rated current and duty cycle Lengths stipulated are the distance from the welder to work and back to the welder again Cable sizes are increased for greater length...

Page 15: ...er cooled diesel made by Perkins OPERATING INSTRUCTIONS Read and understand this entire section before operat ing your equipment SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have...

Page 16: ...mits shown on the chart below OTHER FEATURES Perkins 4 cylinder water cooled diesel engine Designed for long life easy maintenance and excel lent fuel economy Engine protection system shuts the engine...

Page 17: ...ge ENGINE HOUR METER The engine hour meter records the total running time on the engine in hours It can be used to keep a record of maintenance on the engine and or welder ENGINE PROTECTION SYSTEM The...

Page 18: ...AC Receptacle One 15 amp 230 VAC duplex receptacle provides 230 VAC for auxiliary power A total of 13 amps can be drawn from this receptacle Circuit Breakers The circuit breakers provide separate over...

Page 19: ...d may cause engine genera tor or compressor overheating COLD WEATHER STARTING Never use any other starting aids such as ether when using the Thermostart system When overnight temperatures are between...

Page 20: ...mage to electric wiring or to the arc welder if done improperly The use of an arc welder for pipe thawing is not approved by the CSA nor is it recommended or supported by Lincoln Electric K704 Standar...

Page 21: ...to avoid driving dirt into the insulation 2 The current control reactor brushes are self lubricating and should not be greased Keep the contacts clean This control should be moved from maximum to mini...

Page 22: ...n direction of rotation only until brushes seat properly In addition stone slip ring with a fine stone Brushes must be seated 100 Arcing or excessive exciter brush wear indicates a pos sible misaligne...

Page 23: ...er clockwise approximately 1 2 turn and slide it down and off of the element 3 Grasp the element and pull down with a slight rock ing motion to remove the element from the grom met post on the bottom...

Page 24: ...PART NUMBER Engine Air Filter Donaldson P181052 Fan Belt Perkins 2614B550 Compressor Belt Lincoln S23887 SAE400 WELD N AIR only Gates 2 A40 Fuel Filter Perkins 26560143 Engine Oil Filter Perkins 2654...

Page 25: ...der the column labeled PROBLEM SYMP TOMS This column describes possible symptoms that the machine may exhibit Find the listing that best describes the symptom that the machine is exhibiting Step 2 POS...

Page 26: ...ngs may be worn out or missing Contact surface may be dirty rough and pitted Current Control brushholder sup port stud and mating contact sur faces may be dirty or pitted and burned Engine running at...

Page 27: ...or missing Exciter may not be operating Field circuit of generator or exciter may be open Polarity reversing switch may be in the neutral position Exciter may have lost excitation Series field circuit...

Page 28: ...ntrol Current Control shaft and handle may have turned slightly in the insu lated bushing of the current control brushholder caused by turning han dle too hard against one of the stops Exciter output...

Page 29: ...n Authorized Field Service Facility for technical troubleshooting assistance before you proceed CAUTION FUNCTION PROBLEMS PROBLEMS SYMPTOMS POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION No auxiliary pow...

Page 30: ...U BLUE W WHITE Y YELLOW B 235 PARTS CAN INJURE MOVING maintenance work maintenance work unless the maintenance work Keep hands hair clothing and tools away requires it to be running Turn the engine or...

Page 31: ...r input power OFF before Have only qualified personnel perform WARNING from moving parts and insure all guards or covers are replaced after servicing AS REQUIRED DAILY CHECKS LEAD COLOR CODE MAINTENAN...

Page 32: ...REMOTE CONTROL SHOWN IN LOCAL POSITION Y 4 Y 3 X 1 X 4 2 P8 G G Y W W 2 B ELECTRICAL SYMBOLS PER E1537 B B B B B 3 W REMOTE CONTROL RECEPTACLE AND SWITCH REACTOR G N U G F 5 G 4 ALTERNATOR BACK VIEW O...

Page 33: ...ON PRINT F 4 18 50 22 14 22 00 27 12 24 50 8 12 3 00 88 43 75 63 06 39 69 50 13 28 00 32 87 6 00 81 25 69 75 77 00 39 38 44 50 8 90 83 00 81 DIA HOLES 69 DIA HOLES CENTER OF GRAVITY WITH OIL AND WATER...

Page 34: ...SAE400 SAE400 WELD N AIR NOTES...

Page 35: ...n Sie f r gute Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable d...

Page 36: ...Do not touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese d...

Page 37: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Reviews: