Lincoln Electric SAE400 WELD'N AIR Operator'S Manual Download Page 14

BATTERY ACID can burn eyes and
skin.

Wear gloves and eye protection
and be careful when working near
battery.

Follow instructions printed on battery.

IMPORTANT: 

To prevent ELECTRICAL DAMAGE

WHEN:

a) Installing  new batteries. 

b) Using a booster. 

Use correct polarity — 

Negative Ground

.

To prevent BATTERY BUCKLING, tighten nuts on bat-
teries only until snug. 

DO NOT OVERTIGHTEN

.

 Spark Arrester and Muffler may be

hot!

 Allow engine to cool before servicing

spark arrester!

 Do not operate engine while servicing

spark arrester!

SPARK ARRESTER

Some federal, state or local laws may require that
gasoline or diesel engines be equipped with exhaust
spark arresters when they are operated in certain loca-
tions where unarrested sparks may present a fire haz-
ard. The muffler included with this welder has been
modified and now qualifies as a spark arrester.
Mufflers on machines manufactured before this
change do not qualify as spark arresters and when
required by local regulations, a suitable spark arrestor
must be installed. Spark arresting mufflers will have a
clean out service plug and will have “USDA FS 5100-
1c QUALIFIED SPARK ARRESTER” stamped on the
muffler shell. Any spark arrester must be serviced and
properly maintained.

An incorrect arrester may lead to damage to the
engine or adversely affect performance. 
------------------------------------------------------------------------

A-5

INSTALLATION   

SAE400 & SAE400 WELD

N AIR

A-5

WELDING OUTPUT CABLES

With the engine off, connect the electrode and work
cables to the studs provided.  These connections
should be checked periodically and tightened if neces-
sary.  

Listed in Table A.1  are copper cable sizes recom-
mended for the rated current and duty cycle.  Lengths
stipulated are the distance from the welder to work and
back to the welder again.  Cable sizes are increased
for greater lengths primarily for the purpose of mini-
mizing cable voltage drop.

Table A.1 Combined Length of Electrode and

Work Cables.

MACHINE GROUNDING

Because this portable engine driven welder creates its
own power, it is not necessary to connect its frame to
an earth ground, unless the machine is connected to
premises wiring (home, shop, etc.).

To prevent dangerous electric shock, other equipment
powered by  this engine driven welder must:

a) be grounded to the frame of the welder using a

grounded type plug,     or

b) be double insulated.

When this welder is mounted on a truck or trailer, its
frame must be securely connected to the metal frame
of the vehicle. When this engine driven welder is con-
nected to premises wiring such as that in a home or
shop, its frame must be connected to the system earth
ground.  See the article on grounding in the latest U.S.
National Electrical Code and the local code.

In general, if the machine is to be grounded, it should
be connected with a #8 or larger copper wire to a solid
earth ground such as a metal water pipe going into the
ground for at least ten feet and having no insulated
joints, or to the metal framework of a building which
has been effectively grounded. The U.S. National
Electrical Code lists a number of alternate means of
grounding electrical equipment.  A machine grounding
stud marked with the         symbol is provided on the
welding generator frame foot.

Up to 100FT.

Up to 31m

2/0 AWG

100-200FT.

31-61m

3/0 AWG

200-250FT.

61-76m

4/0 AWG

AMPS

@60%

Duty Cycle

400

TOTAL COMBINED LENGTH OF ELEC-

TRODE AND WORK CABLES

WARNING

CAUTION

Summary of Contents for SAE400 WELD'N AIR

Page 1: ...reased by proper installation and thoughtful opera tion on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT And mos...

Page 2: ...R WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy of...

Page 3: ...ical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for co...

Page 4: ...vent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraulic...

Page 5: ...s appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise pai...

Page 6: ...v SAFETY v WARNING Assure that tank and compressor relief valves work properly and are at correct pressure settings NEVER move compressor with pressure in tank DO NOT modify or repair air tank...

Page 7: ...vi SAFETY vi...

Page 8: ...ation below for future reference This information can be found on your machine nameplate Product _________________________________________________________________________________ Model Number ________...

Page 9: ...1 General Description B 1 Recommended Applications B 2 Welder B 2 Auxiliary Power B 2 Compressed Air B 2 Product Application B 2 Design Features and Advantages B 2 Duty Cycle B 2 Engine Controls Funct...

Page 10: ...OR AIR COMPRESSOR OUTPUT SAE400 WELD N AIR ONLY Duty Cycle 1 Welding Output Volts at Rated Amps 60 NEMA 400 amps 36 volts 60 Lincoln Plus 400 amps 40 volts Welding Range Open Circuit Voltage Auxiliary...

Page 11: ...urface directly under stationary or fixed electrical equipment that surface should be covered with a steel plate at least 06 1 6mm thick which should extend not less than 5 90 150mm beyond the equipme...

Page 12: ...es lights fend ers etc VEHICLE MOUNTING Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other compo nents to fail Only transport this equipment on serviceable ve...

Page 13: ...oading occasional moder ate to heavy loading of the engine may sometimes be necessary Caution must be observed in correctly loading a diesel generator unit 1 Connect the welder output studs to a suita...

Page 14: ...pper cable sizes recom mended for the rated current and duty cycle Lengths stipulated are the distance from the welder to work and back to the welder again Cable sizes are increased for greater length...

Page 15: ...er cooled diesel made by Perkins OPERATING INSTRUCTIONS Read and understand this entire section before operat ing your equipment SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have...

Page 16: ...mits shown on the chart below OTHER FEATURES Perkins 4 cylinder water cooled diesel engine Designed for long life easy maintenance and excel lent fuel economy Engine protection system shuts the engine...

Page 17: ...ge ENGINE HOUR METER The engine hour meter records the total running time on the engine in hours It can be used to keep a record of maintenance on the engine and or welder ENGINE PROTECTION SYSTEM The...

Page 18: ...AC Receptacle One 15 amp 230 VAC duplex receptacle provides 230 VAC for auxiliary power A total of 13 amps can be drawn from this receptacle Circuit Breakers The circuit breakers provide separate over...

Page 19: ...d may cause engine genera tor or compressor overheating COLD WEATHER STARTING Never use any other starting aids such as ether when using the Thermostart system When overnight temperatures are between...

Page 20: ...mage to electric wiring or to the arc welder if done improperly The use of an arc welder for pipe thawing is not approved by the CSA nor is it recommended or supported by Lincoln Electric K704 Standar...

Page 21: ...to avoid driving dirt into the insulation 2 The current control reactor brushes are self lubricating and should not be greased Keep the contacts clean This control should be moved from maximum to mini...

Page 22: ...n direction of rotation only until brushes seat properly In addition stone slip ring with a fine stone Brushes must be seated 100 Arcing or excessive exciter brush wear indicates a pos sible misaligne...

Page 23: ...er clockwise approximately 1 2 turn and slide it down and off of the element 3 Grasp the element and pull down with a slight rock ing motion to remove the element from the grom met post on the bottom...

Page 24: ...PART NUMBER Engine Air Filter Donaldson P181052 Fan Belt Perkins 2614B550 Compressor Belt Lincoln S23887 SAE400 WELD N AIR only Gates 2 A40 Fuel Filter Perkins 26560143 Engine Oil Filter Perkins 2654...

Page 25: ...der the column labeled PROBLEM SYMP TOMS This column describes possible symptoms that the machine may exhibit Find the listing that best describes the symptom that the machine is exhibiting Step 2 POS...

Page 26: ...ngs may be worn out or missing Contact surface may be dirty rough and pitted Current Control brushholder sup port stud and mating contact sur faces may be dirty or pitted and burned Engine running at...

Page 27: ...or missing Exciter may not be operating Field circuit of generator or exciter may be open Polarity reversing switch may be in the neutral position Exciter may have lost excitation Series field circuit...

Page 28: ...ntrol Current Control shaft and handle may have turned slightly in the insu lated bushing of the current control brushholder caused by turning han dle too hard against one of the stops Exciter output...

Page 29: ...n Authorized Field Service Facility for technical troubleshooting assistance before you proceed CAUTION FUNCTION PROBLEMS PROBLEMS SYMPTOMS POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION No auxiliary pow...

Page 30: ...U BLUE W WHITE Y YELLOW B 235 PARTS CAN INJURE MOVING maintenance work maintenance work unless the maintenance work Keep hands hair clothing and tools away requires it to be running Turn the engine or...

Page 31: ...r input power OFF before Have only qualified personnel perform WARNING from moving parts and insure all guards or covers are replaced after servicing AS REQUIRED DAILY CHECKS LEAD COLOR CODE MAINTENAN...

Page 32: ...REMOTE CONTROL SHOWN IN LOCAL POSITION Y 4 Y 3 X 1 X 4 2 P8 G G Y W W 2 B ELECTRICAL SYMBOLS PER E1537 B B B B B 3 W REMOTE CONTROL RECEPTACLE AND SWITCH REACTOR G N U G F 5 G 4 ALTERNATOR BACK VIEW O...

Page 33: ...ON PRINT F 4 18 50 22 14 22 00 27 12 24 50 8 12 3 00 88 43 75 63 06 39 69 50 13 28 00 32 87 6 00 81 25 69 75 77 00 39 38 44 50 8 90 83 00 81 DIA HOLES 69 DIA HOLES CENTER OF GRAVITY WITH OIL AND WATER...

Page 34: ...SAE400 SAE400 WELD N AIR NOTES...

Page 35: ...n Sie f r gute Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable d...

Page 36: ...Do not touch electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese d...

Page 37: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Reviews: