GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized
repairs performed on this equipment may result in danger to the technician or machine operator and will
invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety
notes and precautions detailed throughout this manual. If for any reason you do not understand the test
procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department
for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.
TEST DESCRIPTION
This procedure will aid the technician in the removal and replacement of the Generator Frame Assembly.
MATERIALS NEEDED
Miscellaneous Hand Tools
Wiring Diagram
REMOVAL PROCEDURE
1.
Turn off the engine on the SAE-300 HE machine.
2.
Perform the
Alternator Rotor Removal Procedure
3.
Perform the
Alternator Stator Removal Procedure
4.
Label and disconnect all of the wires and cables that connect to the stator/frame assembly. See
Wiring Diagram.
5.
Remove the mounting bolts from the generator feet.
6.
Using a hoist and sling, very carefully lift the generator only enough so the generator frame will
clear the welder frame and can be removed. The sling should be positioned near the center of the
generator frame.
Carefully watch the clearance between the engine and any other components while hoisting,
especially the clearance between the engine fan, the fan shroud and radiator. Loosen or remove
the radiator if necessary.
7.
Support the engine at the generator adapter plate end.
8.
With the generator frame still supported by the sling (be certain the sling is positioned at the center
of gravity of the generator frame) and the weight of the engine resting on the supports that were
placed in the previous step, remove the screws securing the generator frame to the engine adapter
plate.
9.
Carefully pry and wiggle the generator frame to free it from the adapter plate and then slide the
generator frame off of the armature. Adjust the height of the stator frame as needed to assure that
it can slide off the armature without damage to any of the armature or stator windings.
Summary of Contents for SAE-300 HE
Page 8: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 3 Theory of Operation Figure F 1 Block Diagram ...
Page 51: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 46 Figure F 13 Rocker w marks ...
Page 64: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 59 Figure F 22 Rheostat terminal locations ...
Page 68: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 63 Figure F 25 Rotor removal ...
Page 75: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 70 Figure F 28 Sling lift ...
Page 79: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 74 Figure F 30 Current sense board plug location ...
Page 83: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 78 Figure F 32 Rheostat terminal locations ...