TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
ENGINE PROBLEMS
The engine will not crank when
the start button is pressed.
1. The battery may be
discharged. Check and if
necessary, charge or replace
the battery.
2. The battery cables or battery
connections may be loose or
corroded. Service the battery
terminals.
1. Check for battery voltage
where lead 50 connects to the
starter solenoid, while holding
in the start button.
• If no voltage is present, check
the connections and wiring
connecting the starter solenoid
and the start push button
switch. See Wiring Diagram. If
the wiring and connections are
good, replace the push button
switch.
• If voltage is present, check
that the negative battery
terminal is properly connected
to the engine block. If the
battery is properly connected,
the starter/solenoid is defective
and should be serviced or
replaced.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the
Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.
Summary of Contents for SAE-300 HE
Page 8: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 3 Theory of Operation Figure F 1 Block Diagram ...
Page 51: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 46 Figure F 13 Rocker w marks ...
Page 64: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 59 Figure F 22 Rheostat terminal locations ...
Page 68: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 63 Figure F 25 Rotor removal ...
Page 75: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 70 Figure F 28 Sling lift ...
Page 79: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 74 Figure F 30 Current sense board plug location ...
Page 83: ...LINCOLN ELECTRIC SAE 300 HE Service Manual 78 Figure F 32 Rheostat terminal locations ...