A-3
INSTALLATION
SAE-300
®
HE
A-3
Welder Enclosure
- The complete welder is rubber
mountedonaruggedsteel“C”channelbase.
The output terminals are placed at the side of the
machinessothattheyareprotectedbythedoor.The
outputterminalsarel)and(-).
Cranking System
- A 12 volt electric starter is stan-
dard.
Air Cleaner
-Heavydutytwostagedrytype.
Muffler
- A muffler and stainless steel exhaust outlet
elbowarestandard.
Fuel / Hour / LED gauge
-Ametertorecordhoursof
operation,showfuelstatus,batterychargingfaultLED
andenginefaultLED.
Engine Protection -
The system shuts the engine
down in the event of sudden low oil pressure or high
coolant temperature. A warning light on the control
panelwillindicatesuchafault.Toresettheenginefor
restarting,turntheignitionswitchoffthenon.Referto
Troubleshooting section for all warning light fault
codes.
Battery Charging Light -
Awarningindicatorlightfor
Low/Nobatterycharge.Thelightisoffwhenthesys-
temsarefunctioningproperly.Thelightwillcomeonif
there is a Low/No battery condition but the machine
willcontinuetorun.
NOTE
: The light will come on when the Run/Stop
switch is in the “ON” position. It will come on during
cranking and stay on until the engine starts. After,
starting the engine the light will go off unless a
Low/Nobatteryconditionexists.
Oil Drain Valve -
A ball valve, hose and clamp are
standard.
Remote Control
- The Remote / Local Switch and
Receptaclearestandard.
PRE-OPERATION INSTALLATION
ExHAUST SPARK ARRESTER
Some federal, state or local laws may require that
engines be equipped with exhaust spark arresters
when they are operated in certain locations where
unarrested sparks may present a fire hazard. The
standard muffler included with this welder does not
qualify as a spark arrester. When required by local
regulations,asuitablesparkarrestermustbeinstalled
andproperlymaintained.
Useofanincorrectarrestermayleadtoenginedamage
or performance loss. Contact the engine manufacturer
forspecificrecommendations.
------------------------------------------------------------------------
LOCATION / VENTILATION
Always operate the welder with the doors closed.
Leavingthedoorsopenchangesthedesignedairflow
andmaycauseoverheating.
Theweldershouldbelocatedtoprovideanunrestrict-
ed flow of clean, cool air. Also, locate the welder so
that engine exhaust fumes are properly vented to an
outsidearea.
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE ExHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at the
front of this operator’s manual.
-----------------------------------------------------------
WARNING