TROUBLESHOOTING AND REPAIR
F-35
F-35
RANGER® 3 PHASE
This is the typical CV output voltage
generated from a properly operating
machine. Note that each vertical divi-
sion represents 20 volts and that each
horizontal division represents 5 mil-
liseconds in time.
Note:
Scope probes connected at
machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM (CV MODE)
HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM
CH1
5 ms
20 volts
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC