D-3
MAINTENANCE
RANGER
®
330MPX
SPARK ARRESTOR SERvICINg
•
Muffler may be hot
•
Allow the engine to cool before installing the spark
arrestor.
•
Do not operate the engine while installing the spark
arrestor.
Clean every 100 hours.
STORAgE
To prepare the engine for long term storage, run the fuel purge
routine in the Set-up Menu.
Store the Ranger in a clean, dry, protected location.
WELDER gENERATOR MAINTENANCE
Blow out the generator and controls periodically with low pressure
compressed air.
BRuSH REMOvAL AND REPLACEMENT
Do not attempt to polish slip rings while the
engine is running
•
Service and repair should only be performed by Lincoln
Electric Factory Trained Personnel. Unauthorized
repairs may result in danger to the technician and
machine operator and will invalidate your factory
warranty. For your safety and to avoid Electric Shock,
please observe all safety notes and precautions.
It is normal for the brushes and slip rings to wear and darken
slightly. Inspect the brushes every 3 months or 200 hours,
whichever comes first.
NORMAL SERvICE INTERvALS
TABLE D.1
WARNING
WARNING
Item
Service
Interval
Replacement part
number
Part of
K3494-1
Service Kit
Oil and
Oil Filter
5 hours for
first oil
change
2.0 qts 10W-30 for
general use
(-5F to 104F, -
20°C to 40°C)
Y
100 hours
Kohler 12 050 01
Oil Filter
Air Filter
100 hours
Kohler 24 083 03
Air Filter Element
Y
Kohler 24 083 02
Air Filter Pre-
Cleaner
Spark
Plug
500 hours
Champion RC12YC
(.030” gap)
Y
Fuel
Filter
200 hours
Kohler 24 050 13
Y
Brushes
1000 hours
Lincoln G9084-C
N