SPOOL guN OPTIONS
Synergic Control
The spool gun may be set in either “normal” control or “synergic”
control. Synergic mode automatically adjusts the voltage when
the wire feed speed is changed.
SPOOL guN PuLSE
Spool Gun Pulse is only available when an
aluminum wire is selected with the
Ready.Set.Weld menu
Activating Spool Gun Pulse toggles both the
voltage and wire feed speed between a peak and
a low level. It is useful for lower heat input
welding and creating the appearance of “stacked
dimes” in aluminum.
To activate spool gun pulse, the Ready.Set.Weld
entry must be set for an aluminum electrode.
Press the knob for options when in the spool gun
mode. Rotate the knob to choose “Pulse” and
then press the knob. Adjust the pulse frequency
from OFF to 2.5 Hz.
The voltage and wire feed speed values represent
peak values. The lower settings are automatically
calculated based upon the Ready.Set.Weld entries.
B-9
OPERATION
RANGER
®
330MPX
To activate synergic control, press the
knob for options when in the spool gun
mode. Rotate the knob to choose
“Synergic Control” and then press the
knob.
Rotate the knob to change between
normal control and synergic control.
Press the knob to select
?
Press knob to select
Remote
Control
Range
10-22
Synergic
Control
Pulse
Spot Time
?
Voltage
Wire feed speed
Press knob to select
Synergic
Control
Normal
Control
?
Press knob to select
Synergic
Control
Normal
Control
Arc Length
Deposition Rate
?
Press knob to select
Remote
Control
Range
10-22
Pulse
Spot Time
Synergic
Control
?
Press knob to select
Pulse
0.2
Hertz