FIGURE F.1 - SLIP RINGS AND BRUSHES
ROTOR VOLTAGE TEST
(continued)
TEST PROCEDURE
1. With the 5/16” nut driver, remove the 6 sheet
metal screws from the case top.
2. Remove the rubber gasket (cover seal) from the
lift bail.
3. Remove the fuel cap. The rubber gasket for the
fill tube will come off with the case top.
4. Remove the case top,
then reinstall the fuel
cap.
5. With the 5/16” nut driver, remove the 5 screws
holding the right case side.
6. Remove the right case side by lifting up and
out.
7. Set the volt/ohmmeter to the DC volts position.
8. Connect the positive meter probe to the brush
nearest the rotor lamination (lead 200A). See
Figure F.1 for location.
9. Connect the negative meter probe to the other
brush (lead 219).
10. Start the engine and run it at high idle. Set the
output control to the MAXIMUM position (posi-
tion 10).]
11. Check the voltage reading on the voltmeter. It
should read between 32 and 45 VDC.
12. If the voltage reading is low or not present, the
generator field is not functioning properly.
Perform the
Rotor Resis tance Test
.
13. If the voltage reading is normal, the field circuit
is functioning properly. Install the right case
side with the 5 sheet metal screws with the
5/16” nut driver. Remove the fuel cap; install
the case top and tighten the 6 sheet metal
screws with the 5/16” nut driver. Install the
rubber gasket over the lift bail and install the
fuel cap.
TROUBLESHOOTING AND REPAIR
F-16
F-16
RANGER® 225 GXT
Slip Rings
Brushes
Lead 219
+
-
Lead 200A
Slip Rings
Brushes
Lead 219
+
-
Lead 200A
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC