OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
No constant voltage (CV) welding
output. Constant current (CC)
and the auxiliary power are
operating normally.
1. Make sure the Range Switch
(S1) is in the proper position
(CV) and “seated” correctly.
2. Make sure the wire feeder is
connected correctly.
1. Check the operation of the
Range Switch (S1) and check
the associated wires for loose
or faulty connections. See
Wiring Diagram.
2. Check for continuity from lead
C1 to lead W1 located in the
main stator. See Wiring
Diagram.
TROUBLESHOOTING AND REPAIR
F-9
F-9
RANGER® 225 GXT
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Section
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC
Return
to
Master
T
OC